This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions 
{
"resourceType" : "Device",
"id" : "phd-74E8FFFEFF051C00.001C05FFE874",
"meta" : {
"profile" : [
"http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: phd-74E8FFFEFF051C00.001C05FFE874</p><p><b>meta</b>: </p><p><b>identifier</b>: IEEE 11073 System Identifier = 74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address = 00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '65573' = '65573)</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '528388' = '528388)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531976' = '531976)</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531975' = '531975)</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531974' = '531974)</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532352' = '532352)</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532353' = '532353)</span></p><p><b>valueCode</b>: BTLE Pulse Oximeter certified <span style=\"background: LightGoldenRodYellow\">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD code '32772' = 'BTLE Pulse Oximeter certified)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow\">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 code '532354.0' = 'If bit is cleared device is regulated)</span></p><p><b>valueCode</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow\">(Details : {http://terminology.hl7.org/CodeSystem/v2-0136 code 'N' = 'No)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '68220' = '68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532224' = '532224)</span></p></blockquote></div>"
},
"identifier" : [
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID"
}
]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "74-E8-FF-FE-FF-05-1C-00"
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "BTMAC"
}
]
},
"system" : "http://hl7.org/fhir/sid/eui-48",
"value" : "00-1C-05-FF-E8-74"
}
],
"manufacturer" : "Nonin_Medical_Inc.",
"serialNumber" : "501900083",
"modelNumber" : "Model 3230",
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "65573"
}
],
"text" : "MDC_MOC_VMS_MDS_SIMP"
},
"specialization" : [
{
"systemType" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "528388"
}
],
"text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
},
"version" : "1"
}
],
"version" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531976"
}
],
"text" : "MDC_ID_PROD_SPEC_FW: Firmware revision"
},
"value" : "r2.1"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531975"
}
],
"text" : "MDC_ID_PROD_SPEC_SW: Software revision"
},
"value" : "r1.5 9.7"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531974"
}
],
"text" : "MDC_ID_PROD_SPEC_HW: Hardware revision"
},
"value" : "r1.0"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532352"
}
],
"text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value" : "6.0"
}
],
"property" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532353"
}
],
"text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
"code" : "32772"
}
]
}
]
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
"code" : "532354.0"
}
],
"text" : "regulation-status"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "N"
}
],
"text" : "Device is Regulated"
}
]
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220"
}
],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCode" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532224"
}
],
"text" : "MDC_TIME_SYNC_NONE:"
}
]
}
]
}