This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
{ "resourceType" : "Device", "id" : "phd-74E8FFFEFF051C00.001C05FFE874", "meta" : { "profile" : [ "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice" ] }, "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: phd-74E8FFFEFF051C00.001C05FFE874</p><p><b>meta</b>: </p><p><b>identifier</b>: IEEE 11073 System Identifier = 74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address = 00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '65573' = '65573)</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '528388' = '528388)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531976' = '531976)</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531975' = '531975)</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531974' = '531974)</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532352' = '532352)</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532353' = '532353)</span></p><p><b>valueCode</b>: BTLE Pulse Oximeter certified <span style=\"background: LightGoldenRodYellow\">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD code '32772' = 'BTLE Pulse Oximeter certified)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow\">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7 code '532354.0' = 'If bit is cleared device is regulated)</span></p><p><b>valueCode</b>: Device is Regulated <span style=\"background: LightGoldenRodYellow\">(Details : {http://terminology.hl7.org/CodeSystem/v2-0136 code 'N' = 'No)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '68220' = '68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532224' = '532224)</span></p></blockquote></div>" }, "identifier" : [ { "type" : { "coding" : [ { "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers", "code" : "SYSID" } ] }, "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680", "value" : "74-E8-FF-FE-FF-05-1C-00" }, { "type" : { "coding" : [ { "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers", "code" : "BTMAC" } ] }, "system" : "http://hl7.org/fhir/sid/eui-48", "value" : "00-1C-05-FF-E8-74" } ], "manufacturer" : "Nonin_Medical_Inc.", "serialNumber" : "501900083", "modelNumber" : "Model 3230", "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "65573" } ], "text" : "MDC_MOC_VMS_MDS_SIMP" }, "specialization" : [ { "systemType" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "528388" } ], "text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter" }, "version" : "1" } ], "version" : [ { "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "531976" } ], "text" : "MDC_ID_PROD_SPEC_FW: Firmware revision" }, "value" : "r2.1" }, { "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "531975" } ], "text" : "MDC_ID_PROD_SPEC_SW: Software revision" }, "value" : "r1.5 9.7" }, { "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "531974" } ], "text" : "MDC_ID_PROD_SPEC_HW: Hardware revision" }, "value" : "r1.0" }, { "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "532352" } ], "text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" }, "value" : "6.0" } ], "property" : [ { "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "532353" } ], "text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo" }, "valueCode" : [ { "coding" : [ { "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD", "code" : "32772" } ] } ] }, { "type" : { "coding" : [ { "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7", "code" : "532354.0" } ], "text" : "regulation-status" }, "valueCode" : [ { "coding" : [ { "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "N" } ], "text" : "Device is Regulated" } ] }, { "type" : { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "68220" } ], "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" }, "valueCode" : [ { "coding" : [ { "system" : "urn:iso:std:iso:11073:10101", "code" : "532224" } ], "text" : "MDC_TIME_SYNC_NONE:" } ] } ] }