PhdImplementationGuide 0.3.0 - STU 1 (2nd ballot)

This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

Example of a Blood Pressure PHD - TTL Representation

(back to narrative)

Raw ttl

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "phd-711000FEFF5F49B0.B0495F001071"];
  fhir:Resource.meta [
     fhir:Meta.profile [
       fhir:value "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice";
       fhir:index 0;
       fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice>     ]
  ];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: phd-711000FEFF5F49B0.B0495F001071</p><p><b>meta</b>: </p><p><b>identifier</b>: IEEE 11073 System Identifier = 71-10-00-FE-FF-5F-49-B0, Bluetooth MAC address = B0-49-5F-00-10-71</p><p><b>manufacturer</b>: OMRONHEALTHCARE</p><p><b>serialNumber</b>: 20150200002A</p><p><b>modelNumber</b>: HEM-9200T</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '65573' = '65573)</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure Cuff <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '528391' = '528391)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531976' = '531976)</span></p><p><b>value</b>: C.00.7AJ-02</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531975' = '531975)</span></p><p><b>value</b>: 0000000000000101</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '531974' = '531974)</span></p><p><b>value</b>: 0000000000000100</p></blockquote><h3>Properties</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>ValueCode</b></td></tr><tr><td>*</td><td>MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '68220' = '68220)</span></td><td>MDC_TIME_SYNC_NONE: <span style=\"background: LightGoldenRodYellow\">(Details : {urn:iso:std:iso:11073:10101 code '532224' = '532224)</span></td></tr></table></div>"
  ];
  fhir:Device.identifier [
     fhir:index 0;
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers" ];
         fhir:Coding.code [ fhir:value "SYSID" ]       ]     ];
     fhir:Identifier.system [ fhir:value "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680" ];
     fhir:Identifier.value [ fhir:value "71-10-00-FE-FF-5F-49-B0" ]
  ], [
     fhir:index 1;
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers" ];
         fhir:Coding.code [ fhir:value "BTMAC" ]       ]     ];
     fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/sid/eui-48" ];
     fhir:Identifier.value [ fhir:value "B0-49-5F-00-10-71" ]
  ];
  fhir:Device.manufacturer [ fhir:value "OMRONHEALTHCARE"];
  fhir:Device.serialNumber [ fhir:value "20150200002A"];
  fhir:Device.modelNumber [ fhir:value "HEM-9200T"];
  fhir:Device.type [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
       fhir:Coding.code [ fhir:value "65573" ]     ];
     fhir:CodeableConcept.text [ fhir:value "MDC_MOC_VMS_MDS_SIMP" ]
  ];
  fhir:Device.specialization [
     fhir:index 0;
     fhir:Device.specialization.systemType [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
         fhir:Coding.code [ fhir:value "528391" ]       ];
       fhir:CodeableConcept.text [ fhir:value "MDC_DEV_SPEC_PROFILE_BP: Blood Pressure Cuff" ]     ];
     fhir:Device.specialization.version [ fhir:value "1" ]
  ];
  fhir:Device.version [
     fhir:index 0;
     fhir:Device.version.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
         fhir:Coding.code [ fhir:value "531976" ]       ];
       fhir:CodeableConcept.text [ fhir:value "MDC_ID_PROD_SPEC_FW: Firmware revision" ]     ];
     fhir:Device.version.value [ fhir:value "C.00.7AJ-02" ]
  ], [
     fhir:index 1;
     fhir:Device.version.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
         fhir:Coding.code [ fhir:value "531975" ]       ];
       fhir:CodeableConcept.text [ fhir:value "MDC_ID_PROD_SPEC_SW: Software revision" ]     ];
     fhir:Device.version.value [ fhir:value "0000000000000101" ]
  ], [
     fhir:index 2;
     fhir:Device.version.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
         fhir:Coding.code [ fhir:value "531974" ]       ];
       fhir:CodeableConcept.text [ fhir:value "MDC_ID_PROD_SPEC_HW: Hardware revision" ]     ];
     fhir:Device.version.value [ fhir:value "0000000000000100" ]
  ];
  fhir:Device.property [
     fhir:index 0;
     fhir:Device.property.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
         fhir:Coding.code [ fhir:value "68220" ]       ];
       fhir:CodeableConcept.text [ fhir:value "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ]     ];
     fhir:Device.property.valueCode [
       fhir:index 0;
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ];
         fhir:Coding.code [ fhir:value "532224" ]       ];
       fhir:CodeableConcept.text [ fhir:value "MDC_TIME_SYNC_NONE:" ]     ]
  ].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.