This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
<Device xmlns="http://hl7.org/fhir"> <id value="phd-00601900010E9234.F45EABA80832"/> <meta> <profile value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: phd-00601900010E9234.F45EABA80832</p><p><b>meta</b>: </p><p><b>identifier</b>: IEEE 11073 System Identifier = 00-60-19-00-01-0E-92-34, Bluetooth MAC address = F4-5E-AB-A8-08-32</p><p><b>manufacturer</b>: Diabetes Care</p><p><b>serialNumber</b>: 20130200002A</p><p><b>modelNumber</b>: Gluc-23</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '65573' = '65573)</span></p><h3>Specializations</h3><table class="grid"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Monitor <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '528405' = '528405)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '531976' = '531976)</span></p><p><b>value</b>: GLU.7AJ-02</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '531975' = '531975)</span></p><p><b>value</b>: 3.55.6</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '531974' = '531974)</span></p><p><b>value</b>: 5.4.2</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '532353' = '532353)</span></p><p><b>valueCode</b>: HDP BT Glucose Monitor certified <span style="background: LightGoldenRodYellow">(Details : {http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD code '16401' = 'HDP BT Glucose Monitor certified)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '68220' = '68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '532224' = '532224)</span></p></blockquote></div> </text> <identifier> <type> <coding> <system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="00-60-19-00-01-0E-92-34"/> </identifier> <identifier> <type> <coding> <system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="F4-5E-AB-A8-08-32"/> </identifier> <manufacturer value="Diabetes Care"/> <serialNumber value="20130200002A"/> <modelNumber value="Gluc-23"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP"/> </type> <specialization> <systemType> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528405"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Monitor"/> </systemType> <version value="1"/> </specialization> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531976"/> </coding> <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/> </type> <value value="GLU.7AJ-02"/> </version> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="3.55.6"/> </version> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="5.4.2"/> </version> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532353"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo"/> </type> <valueCode> <coding> <system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/> <code value="16401"/> </coding> </valueCode> </property> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCode> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE:"/> </valueCode> </property> </Device>