PhdImplementationGuide 0.3.0 - STU 1 (2nd ballot)

This page is part of the Personal Health Device FHIR IG (v0.3.0: STU 1 Ballot 3) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

Example of a NaN case - XML Representation

(back to narrative)

Raw xml


<Observation xmlns="http://hl7.org/fhir">
  <id value="nan-1.0.0.42"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: nan-1.0.0.42</p><p><b>meta</b>: </p><p><b>status</b>: final</p><p><b>code</b>: MDC_SAT_O2_QUAL: Pulsatile quality <span style="background: LightGoldenRodYellow">(Details : {urn:iso:std:iso:11073:10101 code '150320' = '150320)</span></p><p><b>subject</b>: <a href="nan-1.0.0.42.html">Generated Summary: id: sisansarahId.1.2.3.4.5.6.7.8.10; Medical record number = sisansarahId; Sisansarah Lorianthah Piggy </a></p><p><b>effective</b>: 12/11/2018 11:07:48 AM</p><p><b>dataAbsentReason</b>: not-a-number (Not a number) <span style="background: LightGoldenRodYellow">(Details : {http://terminology.hl7.org/CodeSystem/data-absent-reason code 'not-a-number' = 'Not a Number (NaN))</span></p><p><b>device</b>: <a href="nan-1.0.0.42.html">Generated Summary: id: phd-74E8FFFEFF051C00.001C05FFE874; IEEE 11073 System Identifier = 74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address = 00-1C-05-FF-E8-74; manufacturer: Nonin_Medical_Inc.; serialNumber: 501900083; modelNumber: Model 3230; <span title="Codes: {urn:iso:std:iso:11073:10101 65573}">MDC_MOC_VMS_MDS_SIMP</span></a></p></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
    <valueReference>
      <reference value="Device/phg-ecde3d4e58532d31.000000000000"/>
    </valueReference>
  </extension>
  <status value="final"/>
  <code>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="150320"/>
    </coding>
    <text value="MDC_SAT_O2_QUAL: Pulsatile quality"/>
  </code>
  <subject>
    <reference value="Patient/sisansarahId.1.2.3.4.5.6.7.8.10"/>
  </subject>
  <effectiveDateTime value="2018-11-11T19:07:48-05:00"/>
  <dataAbsentReason>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/data-absent-reason"/>
      <code value="not-a-number"/>
    </coding>
    <text value="not-a-number (Not a number)"/>
  </dataAbsentReason>
  <device>
    <reference value="Device/phd-74E8FFFEFF051C00.001C05FFE874"/>
  </device>
</Observation>