Potential Drug-Drug Interaction (PDDI) CDS IG : STU1 Ballot 2
1.0.0-ballot - STU Ballot International flag

This page is part of the Potential Drug-Drug Interaction (PDDI) Clinical Decision Support (CDS) (FHIR IG) (v1.0.0-ballot: STU 1 Ballot 3) based on FHIR R4. . For a full list of available versions, see the Directory of published versions

: observation-digoxin-cyclosporine-digoxin - TTL Representation

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "observation-digoxin-cyclosporine-digoxin"]; # 
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"observation-digoxin-cyclosporine-digoxin\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation &quot;observation-digoxin-cyclosporine-digoxin&quot; </p></div><p><b>status</b>: final</p><p><b>code</b>: Digoxin [Mass/volume] in Serum or Plasma <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#10535-3)</span></p><p><b>subject</b>: <a href=\"Patient-patient-digoxin-cyclosporine-context.html\">Patient/patient-digoxin-cyclosporine-context</a></p><p><b>issued</b>: Aug 4, 2018 1:34:00 PM</p><p><b>value</b>: 2.3 ng/mL<span style=\"background: LightGoldenRodYellow\"> (Details: SNOMED CT code 258806002 = 'ng/mL')</span></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>0.8</td><td>2.0</td></tr></table></div>"
  ]; # 
  fhir:Observation.status [ fhir:value "final"]; # 
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a loinc:10535-3;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "10535-3" ];
       fhir:Coding.display [ fhir:value "Digoxin [Mass/volume] in Serum or Plasma" ]     ]
  ]; # 
  fhir:Observation.subject [
     fhir:Reference.reference [ fhir:value "Patient/patient-digoxin-cyclosporine-context" ]
  ]; # 
  fhir:Observation.issued [ fhir:value "2018-08-04T14:34:00+01:00"^^xsd:dateTime]; # 
  fhir:Observation.valueQuantity [
     fhir:Quantity.value [ fhir:value "2.3"^^xsd:decimal ];
     fhir:Quantity.unit [ fhir:value "ng/mL" ];
     fhir:Quantity.system [ fhir:value "http://snomed.info/sct" ];
     fhir:Quantity.code [ fhir:value "258806002" ]
  ]; # 
  fhir:Observation.referenceRange [
     fhir:index 0;
     fhir:Observation.referenceRange.low [
       fhir:Quantity.value [ fhir:value "0.8"^^xsd:decimal ]     ];
     fhir:Observation.referenceRange.high [
       fhir:Quantity.value [ fhir:value "2.0"^^xsd:decimal ]     ]
  ]. # 

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.