Order Catalog Implementation Guide
1.0.0 - STU 1 International flag

Order Catalog Implementation Guide - Local Development build (v1.0.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Example ObservationDefinition: Lab observation serum K

Page standards status: Informative

Language: en-US

Profile: Laboratory Observation Definition

status: Active

category: Laboratory

code: Potassium [Moles/volume] in Serum or Plasma

permittedDataType: Quantity, string

multipleResultsAllowed: false

method: Ion Selective Electrode (ISE)

preferredReportName: Potassium

permittedUnit: UCUM: mmol/L (mmol/L), UCUM: g/L (g/L)

qualifiedValue

context: Normal Range

age: 2-19

rangeCategory: reference range

range: 3.8-5.1

qualifiedValue

context: Normal Range

age: 20-?

rangeCategory: reference range

range: 3.5-5.3