This page is part of the Order Catalog Implementation Guide (v0.1.0: STU 1 Ballot 1) based on FHIR R4. . For a full list of available versions, see the Directory of published versions
<SpecimenDefinition xmlns="http://hl7.org/fhir"> <id value="example-specimen-serum-plasma"/> <meta> <profile value="http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition"/> </meta> <language value="en-US"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml" xml:lang="en-US" lang="en-US"><p><b>Generated Narrative</b></p><p><b>id</b>: example-specimen-serum-plasma</p><p><b>meta</b>: </p><p><b>language</b>: en-US</p><p><b>typeCollected</b>: <span title="Codes: {http://terminology.hl7.org/CodeSystem/v2-0487 BLDV}">Blood venous</span></p><p><b>collection</b>: <span title="Codes: {http://snomed.info/sct 28520004}">Venipuncture for blood test</span></p><blockquote><p><b>typeTested</b></p><p><b>type</b>: <span title="Codes: {http://terminology.hl7.org/CodeSystem/v2-0487 SER}">Serum</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table class="grid"><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td><span title="Codes: {http://snomed.info/sct 61088005}">plastic</span></td><td><span title="Codes: {http://snomed.info/sct 767384004}">Evacuated blood collection tube with clot activator</span></td><td><span title="Codes: {http://terminology.hl7.org/CodeSystem/container-cap red}">red cap</span></td><td>red cap plastic tube 5 mL</td><td>10 milliliter</td><td>5 milliliter</td></tr></table><p><b>retentionTime</b>: 24 hour</p><p><b>rejectionCriterion</b>: <span title="Codes: {http://terminology.hl7.org/CodeSystem/rejection-criteria hemolized}">blood specimen hemolized</span>, <span title="Codes: {http://terminology.hl7.org/CodeSystem/rejection-criteria insufficient}">insufficient quantity of specimen</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title="Codes: ">room temperature or refrigerated</span></p><p><b>maxDuration</b>: 7 day</p></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title="Codes: ">frozen</span></p><p><b>maxDuration</b>: 28 day</p></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: <span title="Codes: {http://terminology.hl7.org/CodeSystem/v2-0487 PLAS}">Plasma</span></p><p><b>preference</b>: alternate</p><h3>Containers</h3><table class="grid"><tr><td>-</td><td><b>Type</b></td><td><b>Cap</b></td><td><b>Description</b></td><td><b>Capacity</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td><span title="Codes: {http://snomed.info/sct 767390000}">Evacuated blood collection tube with heparin lithium and gel separator</span></td><td><span title="Codes: {http://terminology.hl7.org/CodeSystem/container-cap green}">green cap</span></td><td>green cap plastic tube 5 mL</td><td>10 milliliter</td><td>5 milliliter</td></tr></table><p><b>retentionTime</b>: 24 hour</p><p><b>rejectionCriterion</b>: <span title="Codes: {http://terminology.hl7.org/CodeSystem/rejection-criteria hemolized}">blood specimen hemolized</span>, <span title="Codes: {http://terminology.hl7.org/CodeSystem/rejection-criteria insufficient}">insufficient quantity of specimen</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title="Codes: ">room temperature or refrigerated</span></p><p><b>maxDuration</b>: 7 day</p></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: <span title="Codes: ">frozen</span></p><p><b>maxDuration</b>: 28 day</p></blockquote></blockquote></div> </text> <typeCollected> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/> <code value="BLDV"/> <display value="Blood venous"/> </coding> </typeCollected> <collection> <coding> <system value="http://snomed.info/sct"/> <code value="28520004"/> <display value="Venipuncture for blood test"/> </coding> </collection> <typeTested> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/> <code value="SER"/> <display value="Serum"/> </coding> </type> <preference value="preferred"/> <container> <material> <coding> <system value="http://snomed.info/sct"/> <code value="61088005"/> <display value="Plastic"/> </coding> <text value="plastic"/> </material> <type> <coding> <system value="http://snomed.info/sct"/> <code value="767384004"/> <display value="Evacuated blood collection tube with clot activator"/> </coding> </type> <cap> <coding> <system value="http://terminology.hl7.org/CodeSystem/container-cap"/> <code value="red"/> </coding> <text value="red cap"/> </cap> <description value="red cap plastic tube 5 mL"/> <capacity> <value value="10"/> <unit value="milliliter"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </capacity> <minimumVolumeQuantity> <value value="5"/> <unit value="milliliter"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </minimumVolumeQuantity> </container> <retentionTime> <value value="24"/> <unit value="hour"/> <system value="http://unitsofmeasure.org"/> <code value="h"/> </retentionTime> <rejectionCriterion> <coding> <system value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/> <code value="hemolized"/> </coding> <text value="blood specimen hemolized"/> </rejectionCriterion> <rejectionCriterion> <coding> <system value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/> <code value="insufficient"/> </coding> <text value="insufficient quantity of specimen"/> </rejectionCriterion> <handling> <temperatureQualifier> <text value="room temperature or refrigerated"/> </temperatureQualifier> <maxDuration> <value value="7"/> <unit value="day"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </maxDuration> </handling> <handling> <temperatureQualifier> <text value="frozen"/> </temperatureQualifier> <maxDuration> <value value="28"/> <unit value="day"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </maxDuration> </handling> </typeTested> <typeTested> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/> <code value="PLAS"/> <display value="Plasma"/> </coding> </type> <preference value="alternate"/> <container> <type> <coding> <system value="http://snomed.info/sct"/> <code value="767390000"/> <display value="Evacuated blood collection tube with heparin lithium and gel separator"/> </coding> </type> <cap> <coding> <system value="http://terminology.hl7.org/CodeSystem/container-cap"/> <code value="green"/> </coding> <text value="green cap"/> </cap> <description value="green cap plastic tube 5 mL"/> <capacity> <value value="10"/> <unit value="milliliter"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </capacity> <minimumVolumeQuantity> <value value="5"/> <unit value="milliliter"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </minimumVolumeQuantity> </container> <retentionTime> <value value="24"/> <unit value="hour"/> <system value="http://unitsofmeasure.org"/> <code value="h"/> </retentionTime> <rejectionCriterion> <coding> <system value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/> <code value="hemolized"/> </coding> <text value="blood specimen hemolized"/> </rejectionCriterion> <rejectionCriterion> <coding> <system value="http://terminology.hl7.org/CodeSystem/rejection-criteria"/> <code value="insufficient"/> </coding> <text value="insufficient quantity of specimen"/> </rejectionCriterion> <handling> <temperatureQualifier> <text value="room temperature or refrigerated"/> </temperatureQualifier> <maxDuration> <value value="7"/> <unit value="day"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </maxDuration> </handling> <handling> <temperatureQualifier> <text value="frozen"/> </temperatureQualifier> <maxDuration> <value value="28"/> <unit value="day"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </maxDuration> </handling> </typeTested> </SpecimenDefinition>