International Patient Summary Implementation Guide
2.0.0-ballot - STU 2 Ballot International flag

This page is part of the International Patient Summary Implementation Guide (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 1.1.0. For a full list of available versions, see the Directory of published versions

Data Type Profile: SimpleQuantity (IPS)

Official URL: http://hl7.org/fhir/uv/ips/StructureDefinition/SimpleQuantity-uv-ips Version: 2.0.0-ballot
Standards status: Trial-use Maturity Level: 2 Computable Name: SimpleQuantityIPS

Data type profile SimpleQuantity constrained to use UCUM as the code system for units

This profile of the SimpleQuantity data type profile imposes the usage of the UCUM code system for units

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from SimpleQuantity

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity 0..* SimpleQuantity A measured amount using UCUM
... system S 1..1 uri UCUM system for units
Fixed Value: http://unitsofmeasure.org
... code S 1..1 code Coded form of the unit

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A measured amount using UCUM
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... system SΣC 1..1 uri UCUM system for units
Fixed Value: http://unitsofmeasure.org
... code SΣ 1..1 code Coded form of the unit

doco Documentation for this format

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()
sqty-1errorQuantityThe comparator is not used on a SimpleQuantity
: comparator.empty()
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A measured amount using UCUM
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... id 0..1 string Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... value Σ 0..1 decimal Numerical value (with implicit precision)
... system SΣC 1..1 uri UCUM system for units
Fixed Value: http://unitsofmeasure.org
... code SΣ 1..1 code Coded form of the unit

doco Documentation for this format

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()
sqty-1errorQuantityThe comparator is not used on a SimpleQuantity
: comparator.empty()

This structure is derived from SimpleQuantity

Summary

Mandatory: 2 elements
Must-Support: 2 elements
Fixed: 1 element

Maturity: 2

Differential View

This structure is derived from SimpleQuantity

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity 0..* SimpleQuantity A measured amount using UCUM
... system S 1..1 uri UCUM system for units
Fixed Value: http://unitsofmeasure.org
... code S 1..1 code Coded form of the unit

doco Documentation for this format

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A measured amount using UCUM
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... system SΣC 1..1 uri UCUM system for units
Fixed Value: http://unitsofmeasure.org
... code SΣ 1..1 code Coded form of the unit

doco Documentation for this format

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()
sqty-1errorQuantityThe comparator is not used on a SimpleQuantity
: comparator.empty()

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* SimpleQuantity A measured amount using UCUM
qty-3: If a code for the unit is present, the system SHALL also be present
sqty-1: The comparator is not used on a SimpleQuantity
... id 0..1 string Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... value Σ 0..1 decimal Numerical value (with implicit precision)
... system SΣC 1..1 uri UCUM system for units
Fixed Value: http://unitsofmeasure.org
... code SΣ 1..1 code Coded form of the unit

doco Documentation for this format

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()
sqty-1errorQuantityThe comparator is not used on a SimpleQuantity
: comparator.empty()

This structure is derived from SimpleQuantity

Summary

Mandatory: 2 elements
Must-Support: 2 elements
Fixed: 1 element

Maturity: 2

 

Other representations of profile: CSV, Excel, Schematron