This page is part of the International Patient Summary Implementation Guide (v0.3.0: STU 1 (FHIR R4) Ballot 1) based on FHIR R4. The current version which supercedes this version is 1.1.0. For a full list of available versions, see the Directory of published versions
Definitions for the StructureDefinition-ImagingStudy-uv-ips Profile.
1. ImagingStudy | |
Definition | Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities. |
Control | 0..* |
Must Support | true |
Invariants | Defined on this element dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (: contained.contained.empty()) dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()) dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()) dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (: contained.meta.security.empty()) dom-6: A resource should have narrative for robust management (: text.div.exists()) |
2. ImagingStudy.id | |
Definition | The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. |
Control | 0..1 |
Type | id |
Comments | The only time that a resource does not have an id is when it is being submitted to the server using a create operation. |
3. ImagingStudy.meta | |
Definition | The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. |
Control | 0..1 |
Type | Meta |
4. ImagingStudy.implicitRules | |
Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. |
Control | 0..1 |
Type | uri |
Is Modifier | true |
Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. |
5. ImagingStudy.language | |
Definition | The base language in which the resource is written. |
Control | 0..1 |
Binding | A human language. The codes SHOULD be taken from CommonLanguages Max Binding: AllLanguages |
Type | code |
Comments | Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
6. ImagingStudy.text | |
Definition | A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. |
Control | 0..1 |
Type | Narrative |
Alternate Names | narrative, html, xhtml, display |
Comments | Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. |
7. ImagingStudy.contained | |
Definition | These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. |
Control | 0..* |
Type | Resource |
Alternate Names | inline resources, anonymous resources, contained resources |
Comments | This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels. |
8. ImagingStudy.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
9. ImagingStudy.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
10. ImagingStudy.identifier | |
Definition | Identifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. |
Note | This is a business identifier, not a resource identifier (see discussion) |
Control | 0..* |
Type | Identifier |
Must Support | true |
Requirements | If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. |
Alternate Names | StudyInstanceUID, AccessionNumber |
Comments | See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. |
11. ImagingStudy.status | |
Definition | The current state of the ImagingStudy. |
Control | 1..1 |
Binding | The status of the ImagingStudy. The codes SHALL be taken from ImagingStudyStatus |
Type | code |
Is Modifier | true |
Comments | Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is. |
12. ImagingStudy.modality | |
Definition | A list of all the series.modality values that are actual acquisition modalities, i.e. those in the DICOM Context Group 29 (value set OID 1.2.840.10008.6.1.19). |
Control | 0..* |
Binding | Type of acquired data in the instance. The codes SHALL be taken from http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_29.html; other codes may be used where these codes are not suitable |
Type | Coding |
Alternate Names | ModalitiesInStudy |
13. ImagingStudy.subject | |
Definition | The subject, typically a patient, of the imaging study. |
Control | 1..1 |
Type | Reference(PatientUvIps) |
Must Support | true |
Comments | QA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group. |
14. ImagingStudy.subject.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
15. ImagingStudy.subject.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices on ImagingStudy.subject.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
|
16. ImagingStudy.subject.reference | |
Definition | A reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. |
Control | 1..1 This element is affected by the following invariants: ref-1 |
Type | string |
Must Support | true |
Comments | Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. |
17. ImagingStudy.subject.type | |
Definition | The expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). |
Control | 0..1 |
Binding | Aa resource (or, for logical models, the URI of the logical model). The codes SHALL be taken from ResourceType; other codes may be used where these codes are not suitable |
Type | uri |
Comments | This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. |
18. ImagingStudy.subject.identifier | |
Definition | An identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. |
Note | This is a business identifier, not a resource identifier (see discussion) |
Control | 0..1 |
Type | Identifier |
Comments | When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). |
19. ImagingStudy.subject.display | |
Definition | Plain text narrative that identifies the resource in addition to the resource reference. |
Control | 0..1 |
Type | string |
Comments | This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. |
20. ImagingStudy.encounter | |
Definition | The healthcare event (e.g. a patient and healthcare provider interaction) during which this ImagingStudy is made. |
Control | 0..1 |
Type | Reference(Encounter) |
Comments | This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test). |
21. ImagingStudy.started | |
Definition | Date and time the study started. |
Control | 0..1 |
Type | dateTime |
Must Support | true |
Alternate Names | StudyDate, StudyTime |
Example | General:2011-01-01T03:01:20-05:00 |
22. ImagingStudy.basedOn | |
Definition | A list of the diagnostic requests that resulted in this imaging study being performed. |
Control | 0..* |
Type | Reference(CarePlan | ServiceRequest | Appointment | AppointmentResponse | Task) |
Requirements | To support grouped procedures (one imaging study supporting multiple ordered procedures, e.g. chest/abdomen/pelvis CT). |
23. ImagingStudy.referrer | |
Definition | The requesting/referring physician. |
Control | 0..1 |
Type | Reference(Practitioner | PractitionerRole) |
Alternate Names | ReferringPhysiciansName |
24. ImagingStudy.interpreter | |
Definition | Who read the study and interpreted the images or other content. |
Control | 0..* |
Type | Reference(Practitioner | PractitionerRole) |
Alternate Names | Name of Physician(s) Reading Study |
25. ImagingStudy.endpoint | |
Definition | The network service providing access (e.g., query, view, or retrieval) for the study. See implementation notes for information about using DICOM endpoints. A study-level endpoint applies to each series in the study, unless overridden by a series-level endpoint with the same Endpoint.connectionType. |
Control | 0..* |
Type | Reference(Endpoint) |
Requirements | Access methods for viewing (e.g., IHE’s IID profile) or retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the study or the study’s series or instances. The study-level baseLocation applies to each series in the study, unless overridden in series by a series-level baseLocation of the same type. |
Comments | Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer. |
26. ImagingStudy.numberOfSeries | |
Definition | Number of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | NumberOfStudyRelatedSeries |
27. ImagingStudy.numberOfInstances | |
Definition | Number of SOP Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | NumberOfStudyRelatedInstances |
28. ImagingStudy.procedureReference | |
Definition | The procedure which this ImagingStudy was part of. |
Control | 0..1 |
Type | Reference(Procedure) |
29. ImagingStudy.procedureCode | |
Definition | A concept that may be defined by a formal reference to a terminology or ontology or may be provided by text. |
Control | 0..* This element is affected by the following invariants: ele-1 |
Binding | The performed procedure type. The codes SHALL be taken from http://www.rsna.org/RadLex_Playbook.aspx; other codes may be used where these codes are not suitable |
Type | CodeableConcept(CodeableConceptIPS) |
Must Support | true |
Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |
30. ImagingStudy.location | |
Definition | The principal physical location where the ImagingStudy was performed. |
Control | 0..1 |
Type | Reference(Location) |
Requirements | Ties the event to where the records are likely kept and provides context around the event occurrence (e.g. if it occurred inside or outside a dedicated healthcare setting). |
31. ImagingStudy.reasonCode | |
Definition | A concept that may be defined by a formal reference to a terminology or ontology or may be provided by text. |
Control | 0..* This element is affected by the following invariants: ele-1 |
Binding | The reason for the study. For example codes, see ProcedureReasonCodes |
Type | CodeableConcept(CodeableConceptIPS) |
Must Support | true |
Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |
32. ImagingStudy.reasonCode.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
33. ImagingStudy.reasonCode.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | This element introduces a set of slices on ImagingStudy.reasonCode.extension. The slices are unordered and Open, and can be differentiated using the following discriminators:
|
34. ImagingStudy.reasonCode.coding | |
Definition | A reference to a code defined by a terminology system. |
Control | 0..* This element is affected by the following invariants: ele-1 |
Type | Coding(CodingIPS) |
Must Support | true |
Requirements | Allows for alternative encodings within a code system, and translations to other code systems. |
Comments | Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |
35. ImagingStudy.reasonCode.text | |
Definition | A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 |
Type | string |
Must Support | true |
Requirements | The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments | Very often the text is the same as a displayName of one of the codings. |
36. ImagingStudy.reasonReference | |
Definition | Indicates another resource whose existence justifies this Study. |
Control | 0..* |
Type | Reference(Condition | Observation | Media | DiagnosticReport | DocumentReference) |
37. ImagingStudy.note | |
Definition | Per the recommended DICOM mapping, this element is derived from the Study Description attribute (0008,1030). Observations or findings about the imaging study should be recorded in another resource, e.g. Observation, and not in this element. |
Control | 0..* |
Type | Annotation |
38. ImagingStudy.description | |
Definition | The Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. |
Control | 0..1 |
Type | string |
Alternate Names | StudyDescription |
39. ImagingStudy.series | |
Definition | Each study has one or more series of images or other content. |
Control | 0..* |
Type | BackboneElement |
Must Support | true |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |
40. ImagingStudy.series.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
41. ImagingStudy.series.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
42. ImagingStudy.series.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
43. ImagingStudy.series.uid | |
Definition | The DICOM Series Instance UID for the series. |
Control | 1..1 |
Type | id |
Must Support | true |
Requirements | DICOM Series Instance UID. |
Alternate Names | SeriesInstanceUID |
Comments | See DICOM PS3.3 C.7.3. |
Example | General:2.16.124.113543.6003.2588828330.45298.17418.2723805630 |
44. ImagingStudy.series.number | |
Definition | The numeric identifier of this series in the study. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | SeriesNumber |
Example | General:3 |
45. ImagingStudy.series.modality | |
Definition | The modality of this series sequence. |
Control | 1..1 |
Binding | Type of acquired data in the instance. The codes SHALL be taken from http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_29.html; other codes may be used where these codes are not suitable |
Type | Coding |
Must Support | true |
Alternate Names | Modality |
46. ImagingStudy.series.description | |
Definition | A description of the series. |
Control | 0..1 |
Type | string |
Alternate Names | SeriesDescription |
Example | General:CT Surview 180 |
47. ImagingStudy.series.numberOfInstances | |
Definition | Number of SOP Instances in the Study. The value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | NumberOfSeriesRelatedInstances |
48. ImagingStudy.series.endpoint | |
Definition | The network service providing access (e.g., query, view, or retrieval) for this series. See implementation notes for information about using DICOM endpoints. A series-level endpoint, if present, has precedence over a study-level endpoint with the same Endpoint.connectionType. |
Control | 0..* |
Type | Reference(Endpoint) |
Requirements | Access methods for retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the series or the series’ instances. A baseLocation specified at the series level has precedence over a baseLocation of the same type specified at the study level. |
Comments | Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances. |
49. ImagingStudy.series.bodySite | |
Definition | The anatomic structures examined. See DICOM Part 16 Annex L (http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_L.html) for DICOM to SNOMED-CT mappings. The bodySite may indicate the laterality of body part imaged; if so, it shall be consistent with any content of ImagingStudy.series.laterality. |
Control | 0..1 |
Binding | Codes describing anatomical locations. May include laterality. For example codes, see SNOMEDCTBodyStructures |
Type | Coding |
Alternate Names | BodyPartExamined |
50. ImagingStudy.series.laterality | |
Definition | The laterality of the (possibly paired) anatomic structures examined. E.g., the left knee, both lungs, or unpaired abdomen. If present, shall be consistent with any laterality information indicated in ImagingStudy.series.bodySite. |
Control | 0..1 |
Binding | Codes describing body site laterality (left, right, etc.). For example codes, see Laterality |
Type | Coding |
51. ImagingStudy.series.specimen | |
Definition | The specimen imaged, e.g., for whole slide imaging of a biopsy. |
Control | 0..* |
Type | Reference(Specimen) |
52. ImagingStudy.series.started | |
Definition | The date and time the series was started. |
Control | 0..1 |
Type | dateTime |
53. ImagingStudy.series.performer | |
Definition | Indicates who or what performed the series and how they were involved. |
Control | 0..* |
Type | BackboneElement |
Requirements | The performer is recorded at the series level, since each series in a study may be performed by a different performer, at different times, and using different devices. A series may be performed by multiple performers. |
Alternate Names | PerformingPhysicianName, OperatorName |
Comments | If the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images. |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |
54. ImagingStudy.series.performer.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
55. ImagingStudy.series.performer.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
56. ImagingStudy.series.performer.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
57. ImagingStudy.series.performer.function | |
Definition | Distinguishes the type of involvement of the performer in the series. |
Control | 0..1 |
Binding | The type of involvement of the performer. The codes SHALL be taken from ImagingStudySeriesPerformerFunction; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | Allows disambiguation of the types of involvement of different performers. |
58. ImagingStudy.series.performer.actor | |
Definition | Indicates who or what performed the series. |
Control | 1..1 |
Type | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | Device | RelatedPerson) |
59. ImagingStudy.series.instance | |
Definition | A single SOP instance within the series, e.g. an image, or presentation state. |
Control | 0..* |
Type | BackboneElement |
Must Support | true |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() or (children().count() > id.count())) |
60. ImagingStudy.series.instance.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
61. ImagingStudy.series.instance.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
62. ImagingStudy.series.instance.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
63. ImagingStudy.series.instance.uid | |
Definition | The DICOM SOP Instance UID for this image or other DICOM content. |
Control | 1..1 |
Type | id |
Must Support | true |
Requirements | DICOM SOP Instance UID. |
Alternate Names | SOPInstanceUID |
Comments | See DICOM PS3.3 C.12.1. |
Example | General:2.16.124.113543.6003.189642796.63084.16748.2599092903 |
64. ImagingStudy.series.instance.sopClass | |
Definition | DICOM instance type. |
Control | 1..1 |
Binding | The sopClass for the instance. The codes SHALL be taken from http://dicom.nema.org/medical/dicom/current/output/chtml/part04/sect_B.5.html#table_B.5-1; other codes may be used where these codes are not suitable |
Type | Coding |
Must Support | true |
Alternate Names | SOPClassUID |
65. ImagingStudy.series.instance.number | |
Definition | The number of instance in the series. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | InstanceNumber |
Example | General:1 |
66. ImagingStudy.series.instance.title | |
Definition | The description of the instance. |
Control | 0..1 |