This page is part of the FHIRcast (v3.0.0-ballot: STU3 (v3.0.0) Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 2.0.0. For a full list of available versions, see the Directory of published versions
eventMaturity | 2 - Tested |
A DiagnosticReport-select
request will be made to the Hub when a Subscriber desires to indicate that one or more FHIR resources contained in the DiagnosticReport context’s content are to be made visible, in focus, or otherwise “selected”. It is assumed that a FHIR resource (e.g., Observation) with the specified id
is contained in the specified anchor context's
content, the Hub MAY or MAY NOT provide validation of its presence.
This event allows other Subscribers to adjust their UIs as appropriate. For example, a reporting system may indicate that the user has selected a particular observation associated with a measurement value. After receiving this event an image reading application which created the measurement may wish to change its user display such that the image from which the measurement was acquired is visible.
If one or more resources are noted as selected, any other resource which had been selected is assumed to be no longer selected (i.e., an implicit unselect of any previously selected resource). Additionally, a Subscriber may indicate that all selections have been cleared by posting a DiagnosticReport-select
with an empty select
array.
Key | Cardinality | Description |
---|---|---|
report |
1..1 | FHIR DiagnosticReport resource specifying the anchor context in which the selection is being made. Note that only the resource.resourceType and resource.id of the anchor context are required to be present. |
select |
1..1 | Contains zero or more references to selected resources in a resources array. If a reference to a resource is present in the resources array, there is an implicit unselect of any previously selected resource. If no resource references are present in the resources array, this is an indication that any previously selected resource is now unselected. |
The following profile provides guidance as to which resource attributes should be present and considerations as to how each attribute should be valued in a DiagnosticReport-select request:
The following example shows the selection of a single Observation resource in an anchor context of a diagnostic report.
{
"timestamp": "2019-09-10T14:58:45.988Z",
"id": "78ef1125-7f8b-4cbc-bc59-a2a02f7e04",
"event": {
"hub.topic": "fdb2f928-5546-4f52-87a0-0648e9ded065",
"hub.event": "DiagnosticReport-select",
"context": [
{
"key": "report",
"resource": {
"resourceType": "DiagnosticReport",
"id": "2402d3bd-e988-414b-b7f2-4322e86c9327",
"status": "unknown",
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "19005-8",
"display": "Radiology Imaging study [Impression] (narrative)"
}
]
}
}
},
{
"key": "select",
"resources": [
{
"resourceType": "Observation",
"id": "40afe766-3628-4ded-b5bd-925727c013b3"
}
]
}
]
}
}
Version | Description |
---|---|
0.1 | Initial draft |
1.0 | Updated for STU3 |