This page is part of the Canonical Resource Management Infrastructure Implementation Guide (v2.0.0-ballot: STU 2 Ballot) based on FHIR (HL7® FHIR® Standard) R4. This version is a pre-release. The current official version is 1.0.0. For a full list of available versions, see the Directory of published versions
Page standards status: Informative |
<Library xmlns="http://hl7.org/fhir">
<id value="manifest-example-initial-draft"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-manifestlibrary"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml">
<div>
<table class="grid dict">
<tr>
<th scope="row"><b>Title: </b></th>
<td style="padding-left: 4px;">eCQM Annual Update 2024</td>
</tr>
<tr>
<th scope="row"><b>Id: </b></th>
<td style="padding-left: 4px;">manifest-example-initial-draft</td>
</tr>
<tr>
<th scope="row"><b>Version: </b></th>
<td style="padding-left: 4px;">1.0.0</td>
</tr>
<tr>
<th scope="row"><b>Url: </b></th>
<td style="padding-left: 4px;"><a href="Library-manifest-example-initial-draft.html">eCQM Annual Update 2024</a></td>
</tr>
<tr>
<th scope="row">
<b>
Official
</b>
</th>
<td style="padding-left: 4px;">
<p style="margin-bottom: 5px;">
<span>eCQM Annual Update 2024</span>
</p>
</td>
</tr>
<tr>
<th scope="row">
<b>
</b>
</th>
<td style="padding-left: 4px;">
<p style="margin-bottom: 5px;">
<span>urn:oid:2.16.840.1.113883.4.642.40.38.28.10</span>
</p>
</td>
</tr>
<tr>
<th scope="row"><b>Status: </b></th>
<td style="padding-left: 4px;">draft</td>
</tr>
<tr>
<th scope="row"><b>Experimental: </b></th>
<td style="padding-left: 4px;">true</td>
</tr>
<tr>
<th scope="row"><b>Type: </b></th>
<td style="padding-left: 4px;">
<p style="margin-bottom: 5px;">
<b>system: </b> <span><a href="http://terminology.hl7.org/6.5.0/CodeSystem-library-type.html">http://terminology.hl7.org/CodeSystem/library-type</a></span>
</p>
<p style="margin-bottom: 5px;">
<b>code: </b> <span>asset-collection</span>
</p>
</td>
</tr>
<tr>
<th scope="row"><b>Date: </b></th>
<td style="padding-left: 4px;">2023-08-01</td>
</tr>
<tr>
<th scope="row"><b>Publisher: </b></th>
<td style="padding-left: 4px;">Clinical Quality Information WG</td>
</tr>
<tr>
<th scope="row"><b>Description: </b></th>
<td style="padding-left: 4px;"><div><p>This library is an example initial draft of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for a collection of measures authored, published, and distributed together, and that are executed with a collective set of expectations documented as part of the release, especially version dependencies for code systems used in value sets referenced by the measures, to ensure predictable expansion of the value sets used to evaluate the measures.</p>
</div></td>
</tr>
<tr>
<th scope="row"><b>Jurisdiction: </b></th>
<td style="padding-left: 4px;">US</td>
</tr>
<tr>
<th scope="row"><b>Purpose: </b></th>
<td style="padding-left: 4px;"><div><p>This library is defined to illustrate a Version Manifest in initial draft status, as it would look at the beginning of an eCQM Annual Update cycle, established on August 1st, 2023. The latest available version of code systems used at that time is specified to provide stability for value set expansion during the authoring phase. Terminology.HL7.org, in particular, was version 5.2.0 at the time, and FHIR code system versions are chosen from that release.</p>
</div></td>
</tr>
<tr>
<th scope="row"><b>Related Artifacts: </b></th>
<td style="padding-left: 4px;">
<p><b>Dependencies</b></p>
<ul>
<li><code>http://snomed.info/sct|http://snomed.info/sct/731000124108/version/20230301</code></li>
<li><code>http://loinc.org|2.7.4</code></li>
</ul>
</td>
</tr>
</table>
</div>
</div>
</text>
<contained>
<Parameters>
<id value="exp-params"/>
<parameter>
<name value="system-version"/>
<valueCanonical
value="http://snomed.info/sct|http://snomed.info/sct/731000124108/version/20230901"/>
</parameter>
<parameter>
<name value="system-version"/>
<valueCanonical value="http://loinc.org|2.74"/>
</parameter>
<parameter>
<name value="activeOnly"/>
<valueBoolean value="true"/>
</parameter>
<parameter>
<name value="includeDraft"/>
<valueBoolean value="true"/>
</parameter>
</Parameters>
</contained>
<contained>
<Parameters>
<id value="endpoints"/>
<parameter>
<name value="artifactEndpointConfiguration"/>
<part>
<name value="artifactRoute"/>
<valueUri
value="http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.464.1003.1167|20220820"/>
</part>
<part>
<name value="endpointUri"/>
<valueUri value="https://example.org/fhir/"/>
</part>
</parameter>
<parameter>
<name value="artifactEndpointConfiguration"/>
<part>
<name value="artifactRoute"/>
<valueUri value="http://cts.nlm.nih.gov/fhir/"/>
</part>
<part>
<name value="endpointUri"/>
<valueUri value="https://uat-cts.nlm.nih.gov/fhir/"/>
</part>
</parameter>
<parameter>
<name value="artifactEndpointConfiguration"/>
<part>
<name value="artifactRoute"/>
<valueUri value="http://terminology.hl7.org/"/>
</part>
<part>
<name value="endpointUri"/>
<valueUri value="https://tx.fhir.org/r4/"/>
</part>
</parameter>
<parameter>
<name value="artifactEndpointConfiguration"/>
<part>
<name value="artifactRoute"/>
<valueUri value="http://hl7.org/fhir/"/>
</part>
<part>
<name value="endpointUri"/>
<valueUri value="https://tx.fhir.org/r4/"/>
</part>
</parameter>
</Parameters>
</contained>
<extension
url="http://hl7.org/fhir/StructureDefinition/cqf-expansionParameters">
<valueReference>
<reference value="#exp-params"/>
</valueReference>
</extension>
<extension
url="http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-endpointConfiguration">
<valueReference>
<reference value="#endpoints"/>
</valueReference>
</extension>
<url
value="http://hl7.org/fhir/uv/crmi/Library/manifest-example-initial-draft"/>
<identifier>
<use value="official"/>
<system value="http://example.org/fhir/cqi/ecqm/Library/Identifier"/>
<value value="eCQM Annual Update 2024"/>
</identifier>
<identifier>
<system value="urn:ietf:rfc:3986"/>
<value value="urn:oid:2.16.840.1.113883.4.642.40.38.28.10"/>
</identifier>
<version value="1.0.0"/>
<name value="ECQMAnnualUpdate2024"/>
<title value="eCQM Annual Update 2024"/>
<status value="draft"/>
<experimental value="true"/>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/library-type"/>
<code value="asset-collection"/>
</coding>
</type>
<date value="2023-08-01"/>
<publisher value="Clinical Quality Information WG"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/cqi"/>
</telecom>
</contact>
<description
value="This library is an example initial draft of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for a collection of measures authored, published, and distributed together, and that are executed with a collective set of expectations documented as part of the release, especially version dependencies for code systems used in value sets referenced by the measures, to ensure predictable expansion of the value sets used to evaluate the measures."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="US"/>
</coding>
</jurisdiction>
<purpose
value="This library is defined to illustrate a Version Manifest in initial draft status, as it would look at the beginning of an eCQM Annual Update cycle, established on August 1st, 2023. The latest available version of code systems used at that time is specified to provide stability for value set expansion during the authoring phase. Terminology.HL7.org, in particular, was version 5.2.0 at the time, and FHIR code system versions are chosen from that release."/>
<relatedArtifact>
<type value="depends-on"/>
<display value="Code system SNOMED-CT US Edition, 2023-03-01"/>
<resource
value="http://snomed.info/sct|http://snomed.info/sct/731000124108/version/20230301"/>
</relatedArtifact>
<relatedArtifact>
<type value="depends-on"/>
<display value="Code system LOINC, 2.7.4"/>
<resource value="http://loinc.org|2.7.4"/>
</relatedArtifact>
</Library>