This page is part of the Clinical Guidelines (v2.0.0-ballot: STU2 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
Active as of 2023-12-19 |
This profile is a _case feature definition_ as part of the Congestive Heart Failure example.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | observation-vitalsigns | FHIR Vital Signs Profile | |
code | 1..1 | CodeableConcept | Potassium | |
Slices for coding | 1..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | |
coding:PotassiumCode | 1..1 | Coding | Code defined by a terminology system | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://loinc.org | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: 86919-8 | |
Slices for value[x] | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Open by type:$this | |
value[x]:valueQuantity | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. | |
value | S | 1..1 | decimal | Numerical value (with implicit precision) |
unit | S | 1..1 | string | Unit representation |
system | S | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | 1..1 | code | % Fixed Value: meq/L | |
Documentation for this format |