StructureDefinition: CHF Net Intake/Output

Active as of 2023-12-19

This profile is a _case feature definition_ as part of the Congestive Heart Failure example.

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..*ObservationMeasurements and simple assertions
... code 1..1CodeableConceptIntake/output
.... Slices for coding 1..*CodingCode defined by a terminology system
Slice: Unordered, Open by value:code, value:system
..... coding:NetIOCode 1..1CodingCode defined by a terminology system
...... system 1..1uriIdentity of the terminology system
Fixed Value: http://hl7.org/fhir/uv/cpg/CodeSystem/chf-codes
...... code 1..1codeSymbol in syntax defined by the system
Fixed Value: net-intake-output
... Slices for value[x] 0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual result
Slice: Unordered, Open by type:$this
.... value[x]:valueQuantity 0..1QuantityActual result
..... value S1..1decimalNumerical value (with implicit precision)
..... unit S1..1stringUnit representation
..... system S1..1uriSystem that defines coded unit form
Fixed Value: http://unitsofmeasure.org
..... code 1..1codeL/d
Fixed Value: L/d