CardX Hypertension Management
1.0.0-ballot - STU1 ballot International flag

This page is part of the CardX Hypertension Management IG (v1.0.0-ballot: STU1 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. . For a full list of available versions, see the Directory of published versions

: SMBP Observation Status value set - JSON Representation

Draft as of 2024-04-05

Raw json | Download


{
  "resourceType" : "ValueSet",
  "id" : "smbp-obs-status",
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><ul><li>Include these codes as defined in <a href=\"http://hl7.org/fhir/R4/codesystem-observation-status.html\"><code>http://hl7.org/fhir/observation-status</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href=\"http://hl7.org/fhir/R4/codesystem-observation-status.html#observation-status-final\">final</a></td><td>Final</td><td>The observation is complete and there are no further actions needed. Additional information such &quot;released&quot;, &quot;signed&quot;, etc would be represented using [Provenance](provenance.html) which provides not only the act but also the actors and dates and other related data. These act states would be associated with an observation status of `preliminary` until they are all completed and then a status of `final` would be applied.</td></tr><tr><td><a href=\"http://hl7.org/fhir/R4/codesystem-observation-status.html#observation-status-entered-in-error\">entered-in-error</a></td><td>Entered in error</td><td>The observation has been withdrawn following previous final release.  This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be &quot;cancelled&quot; rather than &quot;entered-in-error&quot;.).</td></tr><tr><td><a href=\"http://hl7.org/fhir/R4/codesystem-observation-status.html#observation-status-unknown\">unknown</a></td><td>Unknown</td><td>The authoring/source system does not know which of the status values currently applies for this observation. Note: This concept is not to be used for &quot;other&quot; - one of the listed statuses is presumed to apply, but the authoring/source system does not know which.</td></tr></table></li></ul></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "cic"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/cardx-htn-mng/ValueSet/smbp-obs-status",
  "version" : "1.0.0-ballot",
  "name" : "SMBPStatusVS",
  "title" : "SMBP Observation Status value set",
  "status" : "draft",
  "experimental" : false,
  "date" : "2024-04-05T17:50:43+00:00",
  "publisher" : "HL7 International / Clinical Interoperability Council",
  "contact" : [
    {
      "name" : "HL7 International / Clinical Interoperability Council",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/cic"
        },
        {
          "system" : "email",
          "value" : "ciclist@lists.hl7.org"
        }
      ]
    }
  ],
  "description" : "A constraint of the HL7 FHIR Observation Status value set containing only codes relevent to SMBP.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001",
          "display" : "World"
        }
      ]
    }
  ],
  "compose" : {
    "include" : [
      {
        "system" : "http://hl7.org/fhir/observation-status",
        "concept" : [
          {
            "code" : "final",
            "display" : "Final"
          },
          {
            "code" : "entered-in-error",
            "display" : "Entered in error"
          },
          {
            "code" : "unknown",
            "display" : "Unknown"
          }
        ]
      }
    ]
  }
}