Example Observation: Example Observation with AI Assisted security labels

Page standards status: Informative

Security Label: Artificial Intelligence asserted (Details: ObservationValue code AIAST = 'Artificial Intelligence asserted')

status: Final

code: Glasgow Coma Scale , (GCS)

subject: http://server.example.org/fhir/Patient/example

effective: 2014-12-11 04:44:16+0000

performer: AI System (TheAI)

value: 13 {score} (Details: UCUM code{score} = '{score}')

referenceRange

high: 8 {score} (Details: UCUM code{score} = '{score}')

type: Severe TBI

referenceRange

low: 9 {score} (Details: UCUM code{score} = '{score}')

high: 12 {score} (Details: UCUM code{score} = '{score}')

type: Moderate TBI

referenceRange

low: 13 {score} (Details: UCUM code{score} = '{score}')

type: Mild TBI

component

code: GCS Motor

value: 5 (Localizes painful stimuli)

component

code: GSC Verbal

value: 4 (Confused, disoriented)

component

code: Eyes

value: 4 (Opens eyes spontaneously)