Validation Results for AdverseEventClinicalResearch

Generated Tue Apr 30 20:35:51 UTC 2024, FHIR version 5.0.0 for hl7.fhir.uv.ae-research-ig#1.0.1 (canonical = http://hl7.org/fhir/uv/ae-research-ig (history)). See Full QA Report

Quality Checks
Publisher Version:IG Publisher Version: v1.6.6
Publication Code:ae-research-ig . PackageId = hl7.fhir.uv.ae-research-ig, Canonical = http://hl7.org/fhir/uv/ae-research-ig
Realm Check for UV:
  • n/a
Publication Request:
package-idhl7.fhir.uv.ae-research-ig
version1.0.1
pathhttp://hl7.org/fhir/uv/ae-research-ig/STU1
Pub-Modetechnical-correction
statustrial-use
Release-LabelSTU1
sequenceSTU 1
descFHIR STU Release 1 AdverseEvent Clinical Research Profile
descmd

FHIR STU Release 1 AdverseEvent Clinical Research Profile

Proposed path for this publication should usually be the canonical with the version or sequence appended and then some kind of label (typically '-snapshot')
Supressed Messages:17 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.fhir.uv.ae-research-ig1.0.1R5http://hl7.org/fhir/uv/ae-research-ig
... hl7.fhir.uv.extensions.r55.1.0 MR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.1.0
... hl7.terminology5.5.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/5.5.0FHIR Version Mismatch
.... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0FHIR Version Mismatch. Latest Release is 5.1.0
Templates: hl7.vulcan.template#current -> hl7.fhir.template#current -> hl7.base.template#current -> fhir.base.template#current. Tools: 0.1.0
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4 (details)
HTA Analysis:no Non-HL7 references found
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 1.0.0
IPA Comparison: n/a
IPS Comparison: n/a
Summary: errors = 3, warn = 0, info = 0, broken links = 0
FilenameErrorsWarningsHints
Build Errors000
C:\temp\hl7.fhir.uv.ae-research-ig#1.0.1-milestone\fsh-generated\resources\Device-device-infuser300

n/a Show Validation Information


C:\temp\hl7.fhir.uv.ae-research-ig#1.0.1-milestone\fsh-generated\resources\Device-device-infuser.json Show Validation Information (1)

PathSeverityMessage
Device​.identifier[0]​.type​.coding[0]​.system (l9​/c66)errorURL value 'http://hl7.org/fhir/NamingSystem/hibcc-dI' does not resolve

Editor's Comment: Error is due to a known issue that is slated to be addressed see Zulip thread https://chat.fhir.org/#narrow/stream/179166-implementers/topic/Values.20for.20Device.2EudiCarrier.2Eissuer
Device.udiCarrier[0].issuer (l20/c60)errorURL value 'http://hl7.org/fhir/NamingSystem/hibcc-dI' does not resolve

Editor's Comment: Error is due to a known issue that is slated to be addressed see Zulip thread https://chat.fhir.org/#narrow/stream/179166-implementers/topic/Values.20for.20Device.2EudiCarrier.2Eissuer
Device​.udiCarrier[0]​.jurisdiction (l21​/c65)errorURL value 'http://hl7.org/fhir/NamingSystem/fda-udi' does not resolve

Editor's Comment: Error is due to a known issue that is slated to be addressed see Zulip thread https://chat.fhir.org/#narrow/stream/179166-implementers/topic/Values.20for.20Device.2EudiCarrier.2Eissuer

Suppressed Messages (Warnings, hints, broken links)

Error is due to a known issue that is slated to be addressed see Zulip thread https://chat.fhir.org/#narrow/stream/179166-implementers/topic/Values.20for.20Device.2EudiCarrier.2Eissuer

Standards-status extension in use

This is the correct code system URI see https://terminology.hl7.org/5.2.0/CodeSystem-mdr.json.html

reference to adverse-event-category is intended

reference to adverse-event-severity is intended

reference to dose-rate-type is intended

reference to event-status is intended

reference to provenance-participant-type is intended

reference to reason-medication-given is intended

reference to research-study-phase is intended

reference to research-subject-state-type is intended

reference to the THO version of this Code set is intended. The R5 Resource points to a R5 embedded version. The concepts are consistent

Errors sorted by type


Type_Specific_Checks_DT_URL_Resolve

C:\temp\hl7.fhir.uv.ae-research-ig#1.0.1-milestone\fsh-generated\resources\Device-device-infuser.jsonURL value 'http://hl7.org/fhir/NamingSystem/hibcc-dI' does not resolve
C:\temp\hl7.fhir.uv.ae-research-ig#1.0.1-milestone\fsh-generated\resources\Device-device-infuser.jsonURL value 'http://hl7.org/fhir/NamingSystem/hibcc-dI' does not resolve
C:\temp\hl7.fhir.uv.ae-research-ig#1.0.1-milestone\fsh-generated\resources\Device-device-infuser.jsonURL value 'http://hl7.org/fhir/NamingSystem/fda-udi' does not resolve