Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Autopsy-Performed-Indicator' |
Error | StructureDefinition.version | Values for version differ: '3.1.1' vs '1.0.0' |
Information | StructureDefinition.name | Values for name differ: 'USCorePulseOximetryProfile' vs 'VRDR_AutopsyPerformedIndicator' |
Information | StructureDefinition.title | Values for title differ: 'US Core Pulse Oximetry Profile' vs 'VRDR Autopsy Performed Indicator' |
Information | StructureDefinition.status | Values for status differ: 'active' vs 'draft' |
Information | StructureDefinition.date | Values for date differ: '2020-06-29' vs '2020-10-27T16:25:04+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 US Realm Steering Committee' vs 'Health Level Seven International' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/oxygensat' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'FHIR Oxygen Saturation Profile'
'Measurements and simple assertions' |
Warning | Observation | Elements differ in definition:
'This profile defines how to represent pulse oximetry and inspired oxygen concentration based on the FHIR Core Vitals Profile.
INSPIRED OXYGEN CONCENTRATION observations in FHIR using a standard LOINC code and UCUM units of measure.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Warning | Observation.status | Elements differ in short:
'registered | preliminary | final | amended +'
'status' |
Warning | Observation.status | Elements differ in definition:
'The status of the result value.'
'SHALL contain exactly one [1..1] status=''final'' (CONF:4393-412).' |
Error | Observation.status | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Oxygen Saturation by Pulse Oximetry'
'code' |
Warning | Observation.code | Elements differ in definition:
'Oxygen Saturation.'
'SHALL contain exactly one [1..1] code='85699-7' Autopsy was performed (CONF:4393-411).' |
Warning | Observation.code | Elements differ in comments:
'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood -).'
'*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Error | Observation.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in binding.description:
'This identifies the vital sign result type.'
'Codes identifying names of simple observations.' |
Error | Observation.code.coding | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.subject | Elements differ in short:
'Who and/or what the observation is about'
'subject' |
Warning | Observation.subject | Elements differ in definition:
'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.'
'SHALL contain exactly one [1..1] subject='VRDR Decedent' (CONF:4393-413).' |
Error | Observation.subject | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinically relevant time/time-period for observation' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Error | Observation.effective[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'value[x]' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'SHALL contain exactly one [1..1] value[x], where value[x] is (CONF:4393-409)' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Related resource that belongs to the Observation group' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Warning | Observation.component | Elements differ in short:
'Used when reporting systolic and diastolic blood pressure.'
'component' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting systolic and diastolic blood pressure.'
'SHALL contain exactly one [1..1] component (CONF:4393-414).' |
Warning | Observation.component | Elements differ in comments:
'For a discussion on the ways Observations can be assembled in groups together see [Notes] below.'
'Autopsy Results Available' |
Error | Observation.component | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in short:
'Type of component observation (code / type)'
'code' |
Warning | Observation.component.code | Elements differ in definition:
'Describes what was observed. Sometimes this is called the observation 'code'.'
'This component SHALL contain exactly one [1..1] code='69436-4' Autopsy results available (CONF:4393-416).' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'This identifies the vital sign result type.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Value recorded with UCUM'
'value[x]' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Sign Value recorded with UCUM.'
'This component SHALL contain exactly one [1..1] value[x], where value[x] is (CONF:4393-415)' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.value[x] | Elements differ in description:
'Common UCUM units for recording Vital Signs.'
'PHVS_YesNoNotApplicable_NCHS' |
Warning | Observation.component.value[x] | Elements differ in description:
'Common UCUM units for recording Vital Signs.'
'PHVS_YesNoNotApplicable_NCHS' |
Error | Observation.component.value[x] | Unable to resolve right value set https://phinvads.cdc.gov/vads/ViewValueSet.action?oid=2.16.840.1.114222.4.11.7486 at Observation.component.value[x] |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |