Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height' vs 'http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Decedent-Disposition-Method' |
Error | StructureDefinition.version | Values for version differ: '3.1.1' vs '1.0.0' |
Information | StructureDefinition.name | Values for name differ: 'USCorePediatricWeightForHeightObservationProfile' vs 'VRDR_DecedentDispositionMethod' |
Information | StructureDefinition.title | Values for title differ: 'US Core Pediatric Weight for Height Observation Profile' vs 'Decedent Disposition Method' |
Information | StructureDefinition.status | Values for status differ: 'active' vs 'draft' |
Information | StructureDefinition.date | Values for date differ: '2020-06-27' vs '2020-10-27T16:25:04+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 US Realm Steering Committee' vs 'Health Level Seven International' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/vitalsigns' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'FHIR Vital Signs Profile'
'Measurements and simple assertions' |
Warning | Observation | Elements differ in definition:
'This profile defines how to represent Weight-for-length per age and gender observations in FHIR using a standard LOINC code and UCUM units of measure.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Warning | Observation.extension | Elements differ in short:
'Additional content defined by implementations'
'Extension' |
Warning | Observation.extension | Elements differ in definition:
'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.'
'An Extension' |
Warning | Observation.status | Elements differ in short:
'registered | preliminary | final | amended +'
'status' |
Warning | Observation.status | Elements differ in definition:
'The status of the result value.'
'SHALL contain exactly one [1..1] status='final' Final (CONF:4393-162).' |
Error | Observation.status | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Weight-for-length per age and gender'
'code' |
Warning | Observation.code | Elements differ in definition:
'Coded Responses from C-CDA Vital Sign Results.'
'SHALL contain exactly one [1..1] code='80905-3' Body disposition method (CodeSystem: LOINC urn:oid:2.16.840.1.113883.6.1) (CONF:4393-163).' |
Warning | Observation.code | Elements differ in comments:
'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.'
'*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Error | Observation.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in binding.description:
'This identifies the vital sign result type.'
'Codes identifying names of simple observations.' |
Warning | Observation.subject | Elements differ in short:
'Who and/or what the observation is about'
'subject' |
Warning | Observation.subject | Elements differ in definition:
'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.'
'SHALL contain exactly one [1..1] subject (CONF:4393-154).' |
Error | Observation.subject | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinically relevant time/time-period for observation' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Error | Observation.effective[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.performer | Elements differ in short:
'Who is responsible for the observation'
'performer' |
Warning | Observation.performer | Elements differ in definition:
'Who was responsible for asserting the observed value as 'true'.'
'SHALL contain exactly one [1..1] performer (CONF:4393-155).' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'valueCodeableConcept' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Related resource that belongs to the Observation group' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Warning | Observation.component | Elements differ in short:
'Used when reporting systolic and diastolic blood pressure.'
'Component results' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting systolic and diastolic blood pressure.'
'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' |
Error | Observation.component | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'This identifies the vital sign result type.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Value recorded with UCUM'
'Actual component result' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Sign Value recorded with UCUM.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |