Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height vs http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Decedent-Age

Left:US Core Pediatric Weight for Height Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height)
Right:VRDR Decedent Age (http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Decedent-Age)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-height' vs 'http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Decedent-Age'
ErrorStructureDefinition.versionValues for version differ: '3.1.1' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePediatricWeightForHeightObservationProfile' vs 'DecedentAge'
InformationStructureDefinition.titleValues for title differ: 'US Core Pediatric Weight for Height Observation Profile' vs 'VRDR Decedent Age'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2020-06-27' vs '2020-05-10'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'Health Level Seven International'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/vitalsigns' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'FHIR Vital Signs Profile' 'Measurements and simple assertions'
WarningObservationElements differ in definition: 'This profile defines how to represent Weight-for-length per age and gender observations in FHIR using a standard LOINC code and UCUM units of measure.' 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservation.statusElements differ in short: 'registered | preliminary | final | amended +' 'status'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Weight-for-length per age and gender' 'code'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation.'
ErrorObservation.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in binding.description: 'This identifies the vital sign result type.' 'Codes identifying names of simple observations.'
WarningObservation.subjectElements differ in short: 'Who and/or what the observation is about' 'subject'
ErrorObservation.subjectElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.value[x]Elements differ in short: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Used when reporting systolic and diastolic blood pressure.' 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting systolic and diastolic blood pressure.' 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
ErrorObservation.componentElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in binding.description: 'This identifies the vital sign result type.' 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Value recorded with UCUM' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Sign Value recorded with UCUM.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/vitalsignshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyright
      .date2020-06-272020-05-10
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for use in querying and retrieving pediatric Weight-for-length per age and gender observations.The decedent's chronological age at the time of death. When present, the effective date of this observation shall be equal to the decedent's date of death. Age is derived as the difference in time between the decedent's death date and birth date. When age is less than one day then unit shall be minutes, when age is less than one year then unit shall be days, else unit shall be years.
      • Values Differ
      .experimentalfalse
        .fhirVersion4.0.1
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .kindresource
                .nameUSCorePediatricWeightForHeightObservationProfileDecedentAge
                • Values Differ
                .publisherHL7 US Realm Steering CommitteeHealth Level Seven International
                • Values Differ
                .purpose
                  .statusactivedraft
                  • Values Differ
                  .titleUS Core Pediatric Weight for Height Observation ProfileVRDR Decedent Age
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/pediatric-weight-for-heighthttp://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Decedent-Age
                    • Values Differ
                    .version3.1.11.0.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation II
                    • Elements differ in short: "FHIR Vital Signs Profile" "Measurements and simple assertions"
                    • Elements differ in definition: "This profile defines how to represent Weight-for-length per age and gender observations in FHIR using a standard LOINC code and UCUM units of measure." "Measurements and simple assertions made about a patient, device or other subject."
                    ... id ΣΣ
                      ... meta ΣΣ
                        ... implicitRules ?!Σ?!Σ
                          ... language
                            ... text
                              ... contained
                                ... extension ExtensionExtension
                                  ... modifierExtension ?!?!
                                    ... identifier ΣΣ
                                      ... basedOn ΣΣ
                                        ... partOf ΣΣ
                                          ... status ?!SΣ?!Σ
                                          • Elements differ in short: "registered | preliminary | final | amended +" "status"
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... category S(Slice Definition)
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... code SΣΣ
                                          • Elements differ in short: "Weight-for-length per age and gender" "code"
                                          • Elements differ in definition: "Coded Responses from C-CDA Vital Sign Results." "Describes what was observed. Sometimes this is called the observation "name"."
                                          • Elements differ in comments: "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                          • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                          ... subject SΣΣ
                                          • Elements differ in short: "Who and/or what the observation is about" "subject"
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... focus ΣΣ
                                            ... encounter ΣΣ
                                              ... effective[x] SΣIΣ
                                              • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                              • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                              • Elements differ in definition for mustSupport: "true" "false"
                                              ... issued ΣΣ
                                                ... performer ΣΣ
                                                  ... value[x] SΣI(Slice Definition)ΣI
                                                  • Elements differ in short: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "Actual result"
                                                  • Elements differ in definition: "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                  • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                  ... dataAbsentReason SII
                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                  ... interpretation
                                                    ... note
                                                      ... bodySite
                                                        ... method
                                                          ... specimen
                                                            ... device
                                                              ... referenceRange II
                                                                .... id
                                                                  .... extension ExtensionExtension
                                                                    .... modifierExtension ?!Σ?!Σ
                                                                      .... low II
                                                                        .... high II
                                                                          .... type
                                                                            .... appliesTo
                                                                              .... age
                                                                                .... text
                                                                                  ... hasMember ΣΣ
                                                                                  • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                                  • Elements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."
                                                                                  • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                                  ... derivedFrom ΣΣ
                                                                                    ... component SΣIΣ
                                                                                    • Elements differ in short: "Used when reporting systolic and diastolic blood pressure." "Component results"
                                                                                    • Elements differ in definition: "Used when reporting systolic and diastolic blood pressure." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations."
                                                                                    • Elements differ in definition for mustSupport: "true" "false"
                                                                                    .... id
                                                                                      .... extension ExtensionExtension
                                                                                        .... modifierExtension ?!Σ?!Σ
                                                                                          .... code SΣΣ
                                                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                                                          • Elements differ in binding.description: "This identifies the vital sign result type." "Codes identifying names of simple observations."
                                                                                          .... value[x] SΣIΣ
                                                                                          • Elements differ in short: "Vital Sign Value recorded with UCUM" "Actual component result"
                                                                                          • Elements differ in definition: "Vital Sign Value recorded with UCUM." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                          • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                                                          .... dataAbsentReason SII
                                                                                          • Elements differ in definition for mustSupport: "true" "false"
                                                                                          .... interpretation
                                                                                            .... referenceRange

                                                                                              doco Documentation for this format