Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Manner-of-Death

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:VRDR Manner of Death (http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Manner-of-Death)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Manner-of-Death'
ErrorStructureDefinition.versionValues for version differ: '4.0.0' vs '1.2.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'MannerOfDeath'
InformationStructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'VRDR Manner of Death'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2020-11-18' vs '2021-08-13T12:59:07+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'Health Level Seven International'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Pulse Oximetry Profile' 'Measurements and simple assertions'
WarningObservationElements differ in definition: 'Defines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.' 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservation.idElements differ in short: 'Logical id of this artifact' 'id'
WarningObservation.statusElements differ in short: 'registered | preliminary | final | amended +' 'status'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Oxygen Saturation by Pulse Oximetry' 'code'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood).' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation.'
ErrorObservation.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' 'Codes identifying names of simple observations.'
ErrorObservation.code.codingElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.subjectElements differ in short: 'Who and/or what the observation is about' 'subject'
ErrorObservation.subjectElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.performerElements differ in short: 'Who is responsible for the observation' 'performer'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.value[x]Elements differ in description: 'Common UCUM units for recording Vital Signs.' 'PHVS_MannerOfDeath_NCHS'
WarningObservation.value[x]Elements differ in description: 'Common UCUM units for recording Vital Signs.' 'PHVS_MannerOfDeath_NCHS'
ErrorObservation.value[x]Unable to resolve right value set https://phinvads.cdc.gov/vads/ViewValueSet.action?oid=2.16.840.1.114222.4.11.6002 at Observation.value[x]
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Used when reporting flow rates or oxygen concentration.' 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting flow rates or oxygen concentration.' 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
ErrorObservation.componentElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2020-11-182021-08-13T12:59:07+00:00
    • Values Differ
    .descriptionDefines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.
    • Removed the item 'Defines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCorePulseOximetryProfileMannerOfDeath
            • Values Differ
            .publisherHL7 International - US Realm Steering CommitteeHealth Level Seven International
            • Values Differ
            .purpose
              .statusactivedraft
              • Values Differ
              .titleUS Core Pulse Oximetry ProfileVRDR Manner of Death
              • Values Differ
              .typeObservation
                .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Manner-of-Death
                • Values Differ
                .version4.0.01.2.0
                • Values Differ

                Structure

                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                .. Observation II
                • Elements differ in short: "US Core Pulse Oximetry Profile" "Measurements and simple assertions"
                • Elements differ in definition: "Defines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile." "Measurements and simple assertions made about a patient, device or other subject."
                ... id ΣΣ
                • Elements differ in short: "Logical id of this artifact" "id"
                ... meta ΣΣ
                  ... implicitRules ?!Σ?!Σ
                    ... language
                      ... text
                        ... contained
                          ... extension ExtensionExtension
                            ... modifierExtension ?!?!
                              ... identifier ΣΣ
                                ... basedOn ΣΣ
                                  ... partOf ΣΣ
                                    ... status ?!SΣ?!Σ
                                    • Elements differ in short: "registered | preliminary | final | amended +" "status"
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    ... Slices for category S
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    ... code SΣΣ
                                    • Elements differ in short: "Oxygen Saturation by Pulse Oximetry" "code"
                                    • Elements differ in definition: "Coded Responses from C-CDA Vital Sign Results." "Describes what was observed. Sometimes this is called the observation "name"."
                                    • Elements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                    • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation."
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    • Elements differ in binding.description: "The vital sign codes from the base FHIR and US Core Vital Signs." "Codes identifying names of simple observations."
                                    .... id
                                      .... Slices for extension ExtensionExtension
                                        .... Slices for coding SΣΣ
                                        • Elements differ in definition for mustSupport: "true" "false"
                                        .... text ΣΣ
                                          ... subject SΣΣ
                                          • Elements differ in short: "Who and/or what the observation is about" "subject"
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          ... focus ΣΣ
                                            ... encounter ΣΣ
                                              ... effective[x] SΣIΣ
                                              • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                              • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                              • Elements differ in definition for mustSupport: "true" "false"
                                              ... issued ΣΣ
                                                ... performer ΣΣ
                                                • Elements differ in short: "Who is responsible for the observation" "performer"
                                                ... value[x] SΣIΣI
                                                • Elements differ in short: "Vital Signs Value" "Actual result"
                                                • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type." "The information determined as a result of making the observation, if the information has a simple value."
                                                • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                • Elements differ in description: "Common UCUM units for recording Vital Signs." "PHVS_MannerOfDeath_NCHS"
                                                • Elements differ in description: "Common UCUM units for recording Vital Signs." "PHVS_MannerOfDeath_NCHS"
                                                • Unable to resolve right value set https://phinvads.cdc.gov/vads/ViewValueSet.action?oid=2.16.840.1.114222.4.11.6002 at Observation.value[x]
                                                ... dataAbsentReason SII
                                                • Elements differ in definition for mustSupport: "true" "false"
                                                ... interpretation
                                                  ... note
                                                    ... bodySite
                                                      ... method
                                                        ... specimen
                                                          ... device
                                                            ... referenceRange II
                                                              .... id
                                                                .... extension ExtensionExtension
                                                                  .... modifierExtension ?!Σ?!Σ
                                                                    .... low II
                                                                      .... high II
                                                                        .... type
                                                                          .... appliesTo
                                                                            .... age
                                                                              .... text
                                                                                ... hasMember ΣΣ
                                                                                • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                                • Elements differ in definition: "Used when reporting vital signs panel components." "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group."
                                                                                • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                                ... derivedFrom ΣΣ
                                                                                  ... Slices for component SΣIΣ
                                                                                  • Elements differ in short: "Used when reporting flow rates or oxygen concentration." "Component results"
                                                                                  • Elements differ in definition: "Used when reporting flow rates or oxygen concentration." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations."
                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                  .... id
                                                                                    .... extension ExtensionExtension
                                                                                      .... modifierExtension ?!Σ?!Σ
                                                                                        .... code SΣΣ
                                                                                        • Elements differ in definition for mustSupport: "true" "false"
                                                                                        • Elements differ in binding.description: "The vital sign codes from the base FHIR and US Core Vital Signs." "Codes identifying names of simple observations."
                                                                                        .... value[x] SΣIΣ
                                                                                        • Elements differ in short: "Vital Sign Component Value" "Actual component result"
                                                                                        • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                        • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                        • Elements differ in definition for mustSupport: "true" "false"
                                                                                        .... dataAbsentReason SII
                                                                                        • Elements differ in definition for mustSupport: "true" "false"
                                                                                        .... interpretation
                                                                                          .... referenceRange

                                                                                            doco Documentation for this format