This page is part of the Vital Records Mortality and Morbidity Reporting FHIR IG (v0.1.0: STU 1 Ballot 1) based on FHIR R3. The current version which supercedes this version is 2.0.0. For a full list of available versions, see the Directory of published versions
Autopsy Performed Indicator is a profile of the FHIR STU3 Observation resource. It is used to convey a indication as to whether or not an autopsy was performed and whether the results of the autopsy were available for use in declaring the cause of death.
UML Expression
Structure Definition
Observation
|
|
|
Observation |
Data Type Observation
|
id
|
|
0..1
|
|
Short description id
Definition
MAY contain zero or one [0..1] id (CONF:4393-406).
|
meta
|
|
0..1
|
|
Short description meta
Definition
MAY contain zero or one [0..1] meta (CONF:4393-405).
|
profile
|
|
1..1
|
Reference(VRDR Autopsy Performed Indicator)
|
Short description profile
Definition
The meta, if present, SHALL contain exactly one [1..1] profile="http://www.hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Autopsy-Performed-Indicator" (CONF:4393-407).
Data Type Reference(VRDR Autopsy Performed Indicator)
|
status
|
|
1..1
|
codeFixed Value
|
Short description status
Definition
SHALL contain exactly one [1..1] status=""final"" (CONF:4393-412).
Data Type code
Fixed Value
|
code
|
|
1..1
|
CodeableConceptFixed Value
|
Short description code
Definition
SHALL contain exactly one [1..1] code="85699-7" Autopsy was performed (CONF:4393-411).
Data Type CodeableConcept
Fixed Value
{
"coding": [
{
"code": "85699-7",
"display": "Autopsy was performed"
}
]
}
|
subject
|
|
1..1
|
Reference(VRDR Decedent)
|
Short description subject
Definition
SHALL contain exactly one [1..1] subject="VRDR Decedent" (CONF:4393-413).
Data Type Reference(VRDR Decedent)
|
value[x]
|
|
1..1
|
|
Short description value[x]
Definition
SHALL contain exactly one [1..1] value[x], where value[x] is (CONF:4393-409)
Sliced: Unordered, Open, by $this(Type)
|
valueCodeableConcept
|
|
|
Binding |
Short description valueCodeableConcept
Definition
valueCodeableConcept, which SHALL be selected from ValueSet v2-0532 http://www.hl7.org/fhir/ValueSet/v2-0532 DYNAMIC (CONF:4393-410)
Binding v2-0532 (required)
|
component
|
|
1..1
|
|
Short description component
Definition
SHALL contain exactly one [1..1] component (CONF:4393-414).
Comments
Autopsy Results Available
|
code
|
|
1..1
|
CodeableConcept |
Short description code
Definition
This component SHALL contain exactly one [1..1] code=" 69436-4" Autopsy results available (CONF:4393-416).
Data Type CodeableConcept
Pattern
{
"coding": [
{
"code": "69436-4",
"display": "Autopsy results available"
}
]
}
|
value[x]
|
|
1..1
|
|
Short description value[x]
Definition
This component SHALL contain exactly one [1..1] value[x], where value[x] is (CONF:4393-415)
Sliced: Unordered, Open, by $this(Type)
|
valueCodeableConcept
|
|
|
Binding |
Short description valueCodeableConcept
Definition
This component SHALL contain exactly one [1..1] valueCodeableConcept, which SHALL be selected from ValueSet v2-0532 http://www.hl7.org/fhir/ValueSet/v2-0532 DYNAMIC (CONF:4393-417).
Binding v2-0532 (required)
|
Element Bindings
Element Name |
Binding Type |
Binding Value |
Fixed Value Code System |
code |
Fixed Value |
"85699-7" |
LOINC |
component.Autopsy Results Available.code |
Fixed Value |
"69436-4" |
LOINC |
component.Autopsy Results Available.valueCodeableConcept |
Value Set |
v2-0532 |
|
status |
Fixed Value |
"final" |
observation-status |
subject |
Reference |
VRDR Decedent |
|
valueCodeableConcept |
Value Set |
v2-0532 |
|
Element Table
Observation |
|
.. |
Observation.id
|
|
0..1 |
Observation.meta
|
|
0..1 |
Observation.meta.profile
|
Reference(VRDR Autopsy Performed Indicator)
|
1..1 |
Observation.status
|
code |
1..1 |
Observation.code
|
CodeableConcept |
1..1 |
Observation.subject
|
Reference(VRDR Decedent)
|
1..1 |
Observation.value[x]
|
|
1..1 |
Observation.valueCodeableConcept:valueCodeableConcept
|
|
.. |
Observation.component
|
|
1..1 |
Observation.component.code
|
CodeableConcept |
1..1 |
Observation.component.value[x]
|
|
1..1 |
Observation.component.valueCodeableConcept:valueCodeableConcept
|
|
.. |
Requirements Traceability Mappings
Element Path |
Reference |
Location |
Data Item |
valueCodeableConcept |
Vital Records DAM |
2.1.01 Death Event |
autopsyFindingsIndicator |
valueCodeableConcept |
Vital Records DAM |
2.1.01 Death Event |
autopsyPerformedIndicator |
valueCodeableConcept |
Death Certificate |
Item 33 |
Was an Autopsy Performed? |
valueCodeableConcept |
Death Certificate |
Item 34 |
Were Autopsy Findings Available to Complete the Cause of Death? |
valueCodeableConcept |
Standard Death Record IG |
SDR AutopsyPerformed Profile |
Observation.valueBoolean |
valueCodeableConcept |
Standard Death Record IG |
SDR AutopsyResultsAvailable Profile |
Observation.valueBoolean |
Instance Example
<Observation>
<id value="example-autopsy-performed-indicator" />
<meta>
<profile value="http://www.hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Autopsy-Performed-Indicator" />
</meta>
<status value="final" />
<code>
<coding>
<system value="http://loinc.org" />
<code value="85699-7" />
<display value="Autopsy was performed" />
</coding>
</code>
<subject>
<reference value="example-decedent" />
</subject>
<valueCodeableConcept>
<coding>
<system value="http://terminology.www.hl7.org/CodeSystem/v2-0136" />
<code value="N" />
<display value="No" />
</coding>
</valueCodeableConcept>
<component>
<code>
<coding>
<system value="http://loinc.org" />
<code value="69436-4" />
<display value="Autopsy results available" />
</coding>
</code>
<valueCodeableConcept>
<coding>
<system value="http://terminology.www.hl7.org/CodeSystem/v2-0136" />
<code value="N" />
<display value="No" />
</coding>
</valueCodeableConcept>
</component>
</Observation>