Error | StructureDefinition.version | Values for version differ: '0.1.0' vs '1.0.0' |
Information | StructureDefinition.date | Values for date differ: '2020-07-17T18:56:31.000Z' vs '2021-10-12T12:37:45+00:00' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/vitalsigns' vs 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' |
Warning | Observation | Elements differ in short:
'FHIR Vital Signs Profile'
'US Core Vital Signs Profile' |
Warning | Observation | Elements differ in definition:
'The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient.'
'Defines constraints on the Observation resource to represent vital signs observation. This profile is used as the base definition for the other US Core Vital Signs Profiles and based on the FHIR VitalSigns Profile.' |
Warning | Observation.code | Elements differ in short:
'Coded Responses from C-CDA Vital Sign Results'
'Body height Measured' |
Warning | Observation.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'Vital Signs Value' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
'Vital Signs value are typically recorded using the Quantity data type.' |
Warning | Observation.component | Elements differ in short:
'Used when reporting systolic and diastolic blood pressure.'
'Component observations' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting systolic and diastolic blood pressure.'
'Used when reporting component observation such as systolic and diastolic blood pressure.' |
Warning | Observation.component.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.component.code | Elements differ in description:
'This identifies the vital sign result type.'
'The vital sign codes from the base FHIR and US Core Vital Signs.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Value recorded with UCUM'
'Vital Sign Component Value' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Sign Value recorded with UCUM.'
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' |