Profile Comparison between http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-birth-weight vs http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-birth-weight

Left:Observation - Birth Weight (http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-birth-weight)
Right:Observation - Birth Weight (http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-birth-weight)

Messages

ErrorStructureDefinition.versionValues for version differ: '0.1.0' vs '1.0.0'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/Observation' vs 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs'
WarningObservationElements differ in short: 'Measurements and simple assertions' 'US Core Vital Signs Profile'
WarningObservationElements differ in definition: 'Measurements and simple assertions made about a patient, device or other subject.' 'Defines constraints on the Observation resource to represent vital signs observation. This profile is used as the base definition for the other US Core Vital Signs Profiles and based on the FHIR VitalSigns Profile.'
ErrorObservation.statusElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.categoryElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.codeElements differ in short: 'Type of observation (code / type)' 'Coded Responses from C-CDA Vital Sign Results'
WarningObservation.codeElements differ in definition: 'Describes what was observed. Sometimes this is called the observation 'name'.' 'Coded Responses from C-CDA Vital Sign Results.'
WarningObservation.codeElements differ in requirements: 'Knowing what kind of observation is being made is essential to understanding the observation.' '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
ErrorObservation.codeElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.codeElements differ in binding.description: 'Codes identifying names of simple observations.' 'The vital sign codes from the base FHIR and US Core Vital Signs.'
ErrorObservation.subjectElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.effective[x]Elements differ in short: 'Clinically relevant time/time-period for observation' 'Often just a dateTime for Vital Signs'
WarningObservation.effective[x]Elements differ in definition: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' 'Often just a dateTime for Vital Signs.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'false' 'true'
WarningObservation.value[x]Elements differ in short: 'Actual result' 'Vital Signs Value'
WarningObservation.value[x]Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' 'Vital Signs value are typically recorded using the Quantity data type.'
WarningObservation.value[x]Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.hasMemberElements differ in short: 'Related resource that belongs to the Observation group' 'Used when reporting vital signs panel components'
WarningObservation.hasMemberElements differ in definition: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' 'Used when reporting vital signs panel components.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
WarningObservation.componentElements differ in short: 'Component results' 'Component observations'
WarningObservation.componentElements differ in definition: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' 'Used when reporting component observation such as systolic and diastolic blood pressure.'
ErrorObservation.componentElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.component.codeElements differ in binding.description: 'Codes identifying names of simple observations.' 'The vital sign codes from the base FHIR and US Core Vital Signs.'
WarningObservation.component.value[x]Elements differ in short: 'Actual component result' 'Vital Sign Component Value'
WarningObservation.component.value[x]Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'
WarningObservation.component.value[x]Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'false' 'true'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observationhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs
    • Values Differ
    .copyright
      .date2020-07-17T18:56:31.000Z
        .descriptionThe weight of the infant/fetus at birth/delivery.
          .experimental
            .fhirVersion4.0.1
              .jurisdiction
                ..jurisdiction[0]urn:iso:std:iso:3166#US
                  .kindresource
                    .nameObservationBirthWeight
                      .publisherHL7 International - Public Health Work Group
                        .purpose
                          .statusactive
                            .titleObservation - Birth Weight
                              .typeObservation
                                .urlhttp://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-birth-weight
                                  .version0.1.01.0.0
                                  • Values Differ

                                  Structure

                                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                                  .. Observation II
                                  • Elements differ in short: "Measurements and simple assertions" "US Core Vital Signs Profile"
                                  • Elements differ in definition: "Measurements and simple assertions made about a patient, device or other subject." "Defines constraints on the Observation resource to represent vital signs observation. This profile is used as the base definition for the other US Core Vital Signs Profiles and based on the FHIR VitalSigns Profile."
                                  ... id ΣΣ
                                    ... meta ΣΣ
                                      ... implicitRules ?!Σ?!Σ
                                        ... language
                                          ... text
                                            ... contained
                                              ... extension ExtensionExtension
                                                ... modifierExtension ?!?!
                                                  ... identifier ΣΣ
                                                    ... basedOn ΣΣ
                                                      ... partOf ΣΣ
                                                        ... status ?!Σ?!SΣ
                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                        ... category S
                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                        ... code ΣSΣ
                                                        • Elements differ in short: "Type of observation (code / type)" "Coded Responses from C-CDA Vital Sign Results"
                                                        • Elements differ in definition: "Describes what was observed. Sometimes this is called the observation "name"." "Coded Responses from C-CDA Vital Sign Results."
                                                        • Elements differ in requirements: "Knowing what kind of observation is being made is essential to understanding the observation." "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)."
                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                        • Elements differ in binding.description: "Codes identifying names of simple observations." "The vital sign codes from the base FHIR and US Core Vital Signs."
                                                        ... subject ΣSΣ
                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                        ... focus ΣΣ
                                                          ... encounter ΣΣ
                                                            ... effective[x] ΣSΣI
                                                            • Elements differ in short: "Clinically relevant time/time-period for observation" "Often just a dateTime for Vital Signs"
                                                            • Elements differ in definition: "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself." "Often just a dateTime for Vital Signs."
                                                            • Elements differ in definition for mustSupport: "false" "true"
                                                            ... issued ΣΣ
                                                              ... performer ΣΣ
                                                                ... value[x] ΣISΣI
                                                                • Elements differ in short: "Actual result" "Vital Signs Value"
                                                                • Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Signs value are typically recorded using the Quantity data type."
                                                                • Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."
                                                                • Elements differ in definition for mustSupport: "false" "true"
                                                                ... dataAbsentReason ISI
                                                                • Elements differ in definition for mustSupport: "false" "true"
                                                                ... interpretation
                                                                  ... note
                                                                    ... bodySite
                                                                      ... method
                                                                        ... specimen
                                                                          ... device
                                                                            ... referenceRange II
                                                                              .... id
                                                                                .... extension ExtensionExtension
                                                                                  .... modifierExtension ?!Σ?!Σ
                                                                                    .... low II
                                                                                      .... high II
                                                                                        .... type
                                                                                          .... appliesTo
                                                                                            .... age
                                                                                              .... text
                                                                                                ... hasMember ΣΣ
                                                                                                • Elements differ in short: "Related resource that belongs to the Observation group" "Used when reporting vital signs panel components"
                                                                                                • Elements differ in definition: "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group." "Used when reporting vital signs panel components."
                                                                                                • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
                                                                                                ... derivedFrom ΣΣ
                                                                                                  ... component ΣSΣI
                                                                                                  • Elements differ in short: "Component results" "Component observations"
                                                                                                  • Elements differ in definition: "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations." "Used when reporting component observation such as systolic and diastolic blood pressure."
                                                                                                  • Elements differ in definition for mustSupport: "false" "true"
                                                                                                  .... id
                                                                                                    .... extension ExtensionExtension
                                                                                                      .... modifierExtension ?!Σ?!Σ
                                                                                                        .... code ΣSΣ
                                                                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                                                                        • Elements differ in binding.description: "Codes identifying names of simple observations." "The vital sign codes from the base FHIR and US Core Vital Signs."
                                                                                                        .... value[x] ΣSΣI
                                                                                                        • Elements differ in short: "Actual component result" "Vital Sign Component Value"
                                                                                                        • Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept."
                                                                                                        • Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."
                                                                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                                                                        .... dataAbsentReason ISI
                                                                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                                                                        .... interpretation
                                                                                                          .... referenceRange

                                                                                                            doco Documentation for this format