Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus vs http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-mother-height

Left:US Core Smoking Status Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus)
Right:Observation - Mother Height (http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-mother-height)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatus' vs 'http://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-mother-height'
ErrorStructureDefinition.versionValues for version differ: '3.1.1' vs '0.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreSmokingStatusProfile' vs 'ObservationMotherHeight'
InformationStructureDefinition.titleValues for title differ: 'US Core Smoking Status Observation Profile' vs 'Observation - Mother Height'
InformationStructureDefinition.dateValues for date differ: '2019-05-21T00:00:00+00:00' vs '2020-07-17T18:56:31.000Z'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 US Realm Steering Committee' vs 'HL7 International - Public Health Work Group'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/Observation' vs 'http://hl7.org/fhir/StructureDefinition/vitalsigns'
WarningObservationElements differ in short: 'Measurements and simple assertions' 'FHIR Vital Signs Profile'
WarningObservationElements differ in definition: 'The US Core Smoking Status Observation Profile is based upon the core FHIR Observation Resource and created to meet the USCDI Data Set 'Smoking status' requirements.' 'The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient.'
ErrorObservation.categoryElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.codeElements differ in short: 'Smoking Status' 'Coded Responses from C-CDA Vital Sign Results'
WarningObservation.codeElements differ in definition: 'Describes what was observed. Sometimes this is called the observation 'name'.' 'Coded Responses from C-CDA Vital Sign Results.'
WarningObservation.codeElements differ in requirements: 'Knowing what kind of observation is being made is essential to understanding the observation.' '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
WarningObservation.effective[x]Elements differ in short: 'Clinically relevant time/time-period for observation' 'Often just a dateTime for Vital Signs'
WarningObservation.effective[x]Elements differ in definition: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' 'Often just a dateTime for Vital Signs.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.issuedElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.value[x]Elements differ in short: 'Actual result' 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
WarningObservation.value[x]Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
WarningObservation.value[x]Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.hasMemberElements differ in short: 'Related resource that belongs to the Observation group' 'Used when reporting vital signs panel components'
WarningObservation.hasMemberElements differ in definition: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' 'Used when reporting vital signs panel components.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
WarningObservation.componentElements differ in short: 'Component results' 'Used when reporting systolic and diastolic blood pressure.'
WarningObservation.componentElements differ in definition: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' 'Used when reporting systolic and diastolic blood pressure.'
ErrorObservation.componentElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.component.codeElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.component.codeElements differ in binding.description: 'Codes identifying names of simple observations.' 'This identifies the vital sign result type.'
WarningObservation.component.value[x]Elements differ in short: 'Actual component result' 'Vital Sign Value recorded with UCUM'
WarningObservation.component.value[x]Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' 'Vital Sign Value recorded with UCUM.'
WarningObservation.component.value[x]Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
ErrorObservation.component.value[x]Elements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'false' 'true'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observationhttp://hl7.org/fhir/StructureDefinition/vitalsigns
    • Values Differ
    .copyright
      .date2019-05-21T00:00:00+00:002020-07-17T18:56:31.000Z
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve patient's Smoking Status information.The height of the mother.
      • Values Differ
      .experimentalfalse
      • Removed the item 'false'
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
            .kindresource
              .nameUSCoreSmokingStatusProfileObservationMotherHeight
              • Values Differ
              .publisherHL7 US Realm Steering CommitteeHL7 International - Public Health Work Group
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Smoking Status Observation ProfileObservation - Mother Height
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-smokingstatushttp://hl7.org/fhir/us/vr-common-library/StructureDefinition/Observation-mother-height
                    • Values Differ
                    .version3.1.10.1.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation II
                    • Elements differ in short: "Measurements and simple assertions" "FHIR Vital Signs Profile"
                    • Elements differ in definition: "The US Core Smoking Status Observation Profile is based upon the core FHIR Observation Resource and created to meet the USCDI Data Set 'Smoking status' requirements." "The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient."
                    ... id ΣΣ
                      ... meta ΣΣ
                        ... implicitRules ?!Σ?!Σ
                          ... language
                            ... text
                              ... contained
                                ... extension ExtensionExtension
                                  ... modifierExtension ?!?!
                                    ... identifier ΣΣ
                                      ... basedOn ΣΣ
                                        ... partOf ΣΣ
                                          ... status ?!SΣ?!SΣ
                                            ... category S(Slice Definition)
                                            • Elements differ in definition for mustSupport: "false" "true"
                                            ... code SΣSΣ
                                            • Elements differ in short: "Smoking Status" "Coded Responses from C-CDA Vital Sign Results"
                                            • Elements differ in definition: "Describes what was observed. Sometimes this is called the observation "name"." "Coded Responses from C-CDA Vital Sign Results."
                                            • Elements differ in requirements: "Knowing what kind of observation is being made is essential to understanding the observation." "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)."
                                            ... subject SΣSΣ
                                              ... focus ΣΣ
                                                ... encounter ΣΣ
                                                  ... effective[x] ΣSΣI
                                                  • Elements differ in short: "Clinically relevant time/time-period for observation" "Often just a dateTime for Vital Signs"
                                                  • Elements differ in definition: "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself." "Often just a dateTime for Vital Signs."
                                                  • Elements differ in definition for mustSupport: "false" "true"
                                                  ... issued SΣΣ
                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                  ... performer ΣΣ
                                                    ... value[x] ΣI(Slice Definition)SΣI
                                                    • Elements differ in short: "Actual result" "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept."
                                                    • Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept."
                                                    • Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."
                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                    ... dataAbsentReason ISI
                                                    • Elements differ in definition for mustSupport: "false" "true"
                                                    ... interpretation
                                                      ... note
                                                        ... bodySite
                                                          ... method
                                                            ... specimen
                                                              ... device
                                                                ... referenceRange II
                                                                  .... id
                                                                    .... extension ExtensionExtension
                                                                      .... modifierExtension ?!Σ?!Σ
                                                                        .... low II
                                                                          .... high II
                                                                            .... type
                                                                              .... appliesTo
                                                                                .... age
                                                                                  .... text
                                                                                    ... hasMember ΣΣ
                                                                                    • Elements differ in short: "Related resource that belongs to the Observation group" "Used when reporting vital signs panel components"
                                                                                    • Elements differ in definition: "This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group." "Used when reporting vital signs panel components."
                                                                                    • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
                                                                                    ... derivedFrom ΣΣ
                                                                                      ... component ΣSΣI
                                                                                      • Elements differ in short: "Component results" "Used when reporting systolic and diastolic blood pressure."
                                                                                      • Elements differ in definition: "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations." "Used when reporting systolic and diastolic blood pressure."
                                                                                      • Elements differ in definition for mustSupport: "false" "true"
                                                                                      .... id
                                                                                        .... extension ExtensionExtension
                                                                                          .... modifierExtension ?!Σ?!Σ
                                                                                            .... code ΣSΣ
                                                                                            • Elements differ in definition for mustSupport: "false" "true"
                                                                                            • Elements differ in binding.description: "Codes identifying names of simple observations." "This identifies the vital sign result type."
                                                                                            .... value[x] ΣSΣI
                                                                                            • Elements differ in short: "Actual component result" "Vital Sign Value recorded with UCUM"
                                                                                            • Elements differ in definition: "The information determined as a result of making the observation, if the information has a simple value." "Vital Sign Value recorded with UCUM."
                                                                                            • Elements differ in requirements: "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations." "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)."
                                                                                            • Elements differ in definition for mustSupport: "false" "true"
                                                                                            .... dataAbsentReason ISI
                                                                                            • Elements differ in definition for mustSupport: "false" "true"
                                                                                            .... interpretation
                                                                                              .... referenceRange

                                                                                                doco Documentation for this format