Generated Mon Sep 12 00:50:37 UTC 2022, FHIR version 4.0.1 for hl7.fhir.us.vitals#1.0.0 (canonical = http://hl7.org/fhir/us/vitals (history)). See Full QA Report
Quality Checks | |||||||||||||||||||||||||
Publisher Version: | IG Publisher Version: v1.1.131 | ||||||||||||||||||||||||
Publication Code: | vitals . PackageId = hl7.fhir.us.vitals, Canonical = http://hl7.org/fhir/us/vitals | ||||||||||||||||||||||||
Realm Check for US: | Snomed: The IG specifies the US edition of SNOMED CT ✓ | ||||||||||||||||||||||||
Version Check: | 1.0.0 = ok. Step trial-use in sequence STU1 , to be published at http://hl7.org/fhir/us/vitals/STU1 (subdir = STU1). Package-id mismatch between provided and published package-list.json files: hl7.fhir.us.vitals vs hl7.fhir.us.vitalsigns | ||||||||||||||||||||||||
Supressed Messages: | 5 Suppressed Issues | ||||||||||||||||||||||||
Dependency Checks: |
| ||||||||||||||||||||||||
Dependent IGs: | no references | ||||||||||||||||||||||||
Publication Rules: | Code = vitals. All OK (path - http://hl7.org/fhir/us/vitals/STU1) The copyrightYear parameter ('2021+') in the IG resource is good | ||||||||||||||||||||||||
HTA Analysis: | All OK | ||||||||||||||||||||||||
R5 Dependencies: | (none) | ||||||||||||||||||||||||
Modifier Extensions: | (none) | ||||||||||||||||||||||||
Previous Version Comparison: | Unable to compare with previous version: Current Version Comparison failed: Case mismatch of file c:\temp\hl7.fhir.us.vitals#1.0.0-milestone\temp\pages\comparison-v0.1.0\xx-height-height.html: found xx-Height-Height.html | ||||||||||||||||||||||||
IPA Comparison: | n/a | ||||||||||||||||||||||||
Summary: | errors = 3, warn = 0, info = 0, broken links = 0 |
Path | Severity | Message |
Observation.effective.ofType(Period) (l84/c42) | error | Rule vs-1: 'if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day' Failed |
Path | Severity | Message |
Observation.effective.ofType(Period) (l85/c42) | error | Rule vs-1: 'if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day' Failed |
Path | Severity | Message |
Observation.effective.ofType(Period) (l35/c42) | error | Rule vs-1: 'if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day' Failed |
Suppressed Messages (Warnings, hints, broken links)
These are Solor Snomed extension codes.
US Core has a profile of Device called Implantable Device. This is a sibling profile and cannot be used as a base for our BP Device profile. Variance approved by CGP on June 16, 2022, Jira id FHIR-37522.
Using US Core version 3.1.1 which does not define specific profiles for vital signs. This applies to Vital Signs Panel, Average Blood Pressure, Blood Pressure Device, Blood Pressure Panel, Body Length, Body Mass Index, Body Temperature, Body Weight, Head Occipital-Frontal Circumference, Heart Rate, Height, Oxygen Saturation Arterial Blood, and Respiratory Rate. Variance approved by CGP on June 16, 2022, Jira id FHIR-37522.
Using a madeup system for example codes in the Patient and Provider examples.
Errors sorted by type