This page is part of the Vital Signs FHIR IG (v1.0.0: STU1) based on FHIR R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Active as of 2022-09-12 |
<ValueSet xmlns="http://hl7.org/fhir">
<id value="respiratoryRateMeasDeviceVS"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p>This value set includes codes based on the following rules:</p><ul><li>Include these codes as defined in <a href="http://www.snomed.org/"><code>http://snomed.info/sct</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="http://snomed.info/id/717730001">717730001</a></td><td>Impedance pneumography recording/analysis system (physical object)</td></tr><tr><td><a href="http://snomed.info/id/334990001">334990001</a></td><td>Peak flow meter (physical object)</td></tr><tr><td><a href="http://snomed.info/id/462575001">462575001</a></td><td>Patient monitoring system module, electrocardiographic/respiratory (physical object)</td></tr><tr><td><a href="http://snomed.info/id/463005003">463005003</a></td><td>Patient monitoring system module, respiratory (physical object)</td></tr></table></li><li>Include these codes as defined in <a href="CodeSystem-SolorTemporaryCodeSystem.html"><code>http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-23921000205109">23921000205109</a></td><td>Respiration strain gauge (physical object)</td><td>A device wrapped around a subject chest that measures the number of times a subject's chest expands with each inhalation. This counts the breaths per minute.</td></tr><tr><td><a href="CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-23861000205107">23861000205107</a></td><td>Capnograph sensor device (physical object)</td><td>A device that captures expelled air, either via nasal prongs or CPAP and is used to measure the number of breaths taken per minute.</td></tr></table></li></ul></div>
</text>
<url
value="http://hl7.org/fhir/us/vitals/ValueSet/respiratoryRateMeasDeviceVS"/>
<version value="1.0.0"/>
<name value="RespiratoryRateMeasurementDevicevalueset"/>
<title value="Respiratory Rate Measurement Device value set"/>
<status value="active"/>
<date value="2022-09-12T00:47:55+00:00"/>
<publisher
value="HL7 International - Clinical Information Modeling Initiative"/>
<contact>
<name value="HL7 International - Clinical Information Modeling Initiative"/>
<telecom>
<system value="url"/>
<value value="http://hl7.org/Special/committees/cimi"/>
</telecom>
</contact>
<contact>
<name value="Logica"/>
<telecom>
<system value="url"/>
<value value="https://www.logicahealth.org/"/>
</telecom>
</contact>
<description
value="SELECT SNOMED CT code system values that describe instruments used to measure respiratory rates."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="US"/>
<display value="United States of America"/>
</coding>
</jurisdiction>
<copyright
value="This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
<compose>
<include>
<system value="http://snomed.info/sct"/>
<concept>
<code value="717730001"/>
<display
value="Impedance pneumography recording/analysis system (physical object)"/>
</concept>
<concept>
<code value="334990001"/>
<display value="Peak flow meter (physical object)"/>
</concept>
<concept>
<code value="462575001"/>
<display
value="Patient monitoring system module, electrocardiographic/respiratory (physical object)"/>
</concept>
<concept>
<code value="463005003"/>
<display
value="Patient monitoring system module, respiratory (physical object)"/>
</concept>
</include>
<include>
<system
value="http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem"/>
<concept>
<code value="23921000205109"/>
<display value="Respiration strain gauge (physical object)"/>
</concept>
<concept>
<code value="23861000205107"/>
<display value="Capnograph sensor device (physical object)"/>
</concept>
</include>
</compose>
</ValueSet>