This page is part of the Vital Signs FHIR IG (v1.0.0: STU1) based on FHIR R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Active as of 2022-09-12 |
{
"resourceType" : "ValueSet",
"id" : "bpMeasMethodVS",
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>This value set includes codes based on the following rules:</p><ul><li>Include these codes as defined in <a href=\"http://www.snomed.org/\"><code>http://snomed.info/sct</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href=\"http://snomed.info/id/77938009\">77938009</a></td><td>Arterial pressure monitoring, invasive method (regime/therapy)</td></tr><tr><td><a href=\"http://snomed.info/id/17146006\">17146006</a></td><td>Arterial pressure monitoring, non-invasive method (regime/therapy)</td></tr><tr><td><a href=\"http://snomed.info/id/37931006\">37931006</a></td><td>Auscultation (procedure)</td></tr><tr><td><a href=\"http://snomed.info/id/765172009\">765172009</a></td><td>Doppler ultrasound (procedure)</td></tr><tr><td><a href=\"http://snomed.info/id/13385008\">13385008</a></td><td>Mediate auscultation (procedure)</td></tr><tr><td><a href=\"http://snomed.info/id/113011001\">113011001</a></td><td>Palpation (procedure)</td></tr><tr><td><a href=\"http://snomed.info/id/31813000\">31813000</a></td><td>Vascular oscillometry (procedure)</td></tr></table></li><li>Include these codes as defined in <a href=\"CodeSystem-SolorTemporaryCodeSystem.html\"><code>http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem</code></a><table class=\"none\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href=\"CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-911000205109\">911000205109</a></td><td>Measurement of blood pressure using intravascular transducer (procedure)</td><td>A device that measures blood pressure intravascularly via a trandsducer.</td></tr><tr><td><a href=\"CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-641000205104\">641000205104</a></td><td>Auscultation - automatic (procedure)</td><td>A procedure that uses a computer aided device to measure blood pressure.</td></tr></table></li></ul></div>"
},
"url" : "http://hl7.org/fhir/us/vitals/ValueSet/bpMeasMethodVS",
"version" : "1.0.0",
"name" : "BloodPressureMeasurementMethodvalueset",
"title" : "Blood Pressure Measurement Method value set",
"status" : "active",
"date" : "2022-09-12T00:47:55+00:00",
"publisher" : "HL7 International - Clinical Information Modeling Initiative",
"contact" : [
{
"name" : "HL7 International - Clinical Information Modeling Initiative",
"telecom" : [
{
"system" : "url",
"value" : "http://hl7.org/Special/committees/cimi"
}
]
},
{
"name" : "Logica",
"telecom" : [
{
"system" : "url",
"value" : "https://www.logicahealth.org/"
}
]
}
],
"description" : "SELECT SNOMED CT code system values that describe how a blood pressure was measured.",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "US",
"display" : "United States of America"
}
]
}
],
"copyright" : "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement",
"compose" : {
"include" : [
{
"system" : "http://snomed.info/sct",
"concept" : [
{
"code" : "77938009",
"display" : "Arterial pressure monitoring, invasive method (regime/therapy)"
},
{
"code" : "17146006",
"display" : "Arterial pressure monitoring, non-invasive method (regime/therapy)"
},
{
"code" : "37931006",
"display" : "Auscultation (procedure)"
},
{
"code" : "765172009",
"display" : "Doppler ultrasound (procedure)"
},
{
"code" : "13385008",
"display" : "Mediate auscultation (procedure)"
},
{
"code" : "113011001",
"display" : "Palpation (procedure)"
},
{
"code" : "31813000",
"display" : "Vascular oscillometry (procedure)"
}
]
},
{
"system" : "http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem",
"concept" : [
{
"code" : "911000205109",
"display" : "Measurement of blood pressure using intravascular transducer (procedure)"
},
{
"code" : "641000205104",
"display" : "Auscultation - automatic (procedure)"
}
]
}
]
}
}