Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-social-history vs http://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood

Left:US Core Observation Social History Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-social-history)
Right:Oxygen Saturation in Arterial blood, method not specified (http://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-social-history' vs 'http://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood'
ErrorStructureDefinition.versionValues for version differ: '5.0.1' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreObservationSocialHistoryProfile' vs 'OxygenSaturationArterialBlood'
InformationStructureDefinition.titleValues for title differ: 'US Core Observation Social History Profile' vs 'Oxygen Saturation in Arterial blood, method not specified'
InformationStructureDefinition.dateValues for date differ: '2022-04-20' vs '2022-09-12T00:45:08+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International - Clinical Information Modeling Initiative'
InformationStructureDefinition.copyrightValues for copyright differ: 'Used by permission of HL7 International, all rights reserved Creative Commons License' vs 'Logica Health, all rights reserved Creative Commons License'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/Observation' vs 'http://hl7.org/fhir/StructureDefinition/oxygensat'
WarningObservationElements differ in short: 'assessment observation' vs 'FHIR Oxygen Saturation Profile'
WarningObservationElements differ in definition: '\-' vs 'This profile defines how to represent Oxygen Saturation observations in FHIR using a standard LOINC code and UCUM units of measure.'
WarningObservationElements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
WarningObservation.codeElements differ in short: 'Type of observation (code / type)' vs 'Oxygen saturation in Arterial blood'
WarningObservation.codeElements differ in definition: 'Describes what was observed. Sometimes this is called the observation 'name'.' vs 'Oxygen Saturation.'
WarningObservation.codeElements differ in comments: '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' vs 'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.'
WarningObservation.codeElements differ in requirements: 'Knowing what kind of observation is being made is essential to understanding the observation.' vs '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
WarningObservation.effective[x]Elements differ in short: 'Clinically relevant time/time-period for observation' vs 'Often just a dateTime for Vital Signs'
WarningObservation.effective[x]Elements differ in definition: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'.' vs 'Often just a dateTime for Vital Signs.'
WarningObservation.effective[x]Elements differ in comments: 'At least a date should be present unless this observation is a historical report.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing] datatype which allow the measurement to be tied to regular life events.'
InformationObservation.effective[x]Element minimum cardinalities differ: '0' vs '1'
WarningObservation.performerElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.value[x]Elements differ in short: 'Actual result' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
WarningObservation.value[x]Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
WarningObservation.value[x]Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.interpretationElements differ in definition for mustSupport: 'false' vs 'true'
InformationObservation.interpretationElement maximum cardinalities differ: '2147483647' vs '1'
WarningObservation.hasMemberElements differ in short: 'Related resource that belongs to the Observation group' vs 'Used when reporting vital signs panel components'
WarningObservation.hasMemberElements differ in definition: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' vs 'Used when reporting vital signs panel components.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
WarningObservation.componentElements differ in short: 'Component results' vs 'Used when reporting systolic and diastolic blood pressure.'
WarningObservation.componentElements differ in definition: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' vs 'Used when reporting systolic and diastolic blood pressure.'
WarningObservation.componentElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.component.codeElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.component.codeElements differ in binding.description: 'Codes identifying names of simple observations.' vs 'This identifies the vital sign result type.'
WarningObservation.component.value[x]Elements differ in short: 'Actual component result' vs 'Vital Sign Value recorded with UCUM'
WarningObservation.component.value[x]Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Sign Value recorded with UCUM.'
WarningObservation.component.value[x]Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'false' vs 'true'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observationhttp://hl7.org/fhir/StructureDefinition/oxygensat
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons LicenseLogica Health, all rights reserved Creative Commons License
    • Values Differ
    .date2022-04-202022-09-12T00:45:08+00:00
    • Values Differ
    .descriptionThe US Core Observation Social History Profile meets the U.S. Core Data for Interoperability (USCDI) v2 ‘SDOH Assessments’ requirements. To promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch retrieve observations that represent simple observations made by an individual about a patient's social history status such as education, food insecurity, etc. It identifies which core elements, extensions, vocabularies and value sets **SHALL** be present in the resource when using this profile. It provides the floor for standards development for specific uses cases.A measurement of the percentage to which oxygen is bound to hemoglobin in arterial blood.
    • Values Differ
    .experimental
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
            .kindresource
              .nameUSCoreObservationSocialHistoryProfileOxygenSaturationArterialBlood
              • Values Differ
              .publisherHL7 International - Cross-Group ProjectsHL7 International - Clinical Information Modeling Initiative
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Observation Social History ProfileOxygen Saturation in Arterial blood, method not specified
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-social-historyhttp://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood
                    • Values Differ
                    .version5.0.11.0.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation C0..*Observationassessment observation
                    C0..*observation-oxygensatFHIR Oxygen Saturation Profile
                    • Elements differ in short: 'assessment observation' vs 'FHIR Oxygen Saturation Profile'
                    • Elements differ in definition: '\-' vs 'This profile defines how to represent Oxygen Saturation observations in FHIR using a standard LOINC code and UCUM units of measure.'
                    • Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
                    ... id Σ0..1stringLogical id of this artifactΣ0..1idLogical id of this artifact
                      ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                        ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                          ... language 0..1codeLanguage of the resource content
                          Binding: CommonLanguages (preferred): A human language.

                          Additional BindingsPurpose
                          AllLanguagesMax Binding
                          0..1codeLanguage of the resource content
                          Binding: CommonLanguages (preferred): A human language.

                          Additional BindingsPurpose
                          AllLanguagesMax Binding
                            ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                              ... contained 0..*ResourceContained, inline Resources
                              0..*ResourceContained, inline Resources
                                ... extension 0..*ExtensionAdditional content defined by implementations
                                0..*ExtensionAdditional content defined by implementations
                                  ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                  ?!0..*ExtensionExtensions that cannot be ignored
                                    ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                    Σ0..*IdentifierBusiness Identifier for observation
                                      ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                      Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                        ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                        Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                          ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                          Binding: ObservationStatus (required): Codes providing the status of an observation.

                                          ?!SΣ1..1coderegistered | preliminary | final | amended +
                                          Binding: ObservationStatus (required)
                                            ... Slices for category S1..*CodeableConceptClassification of type of observation
                                            Slice: Unordered, Open by pattern:$this
                                            Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


                                            S1..*CodeableConceptClassification of type of observation
                                            Slice: Unordered, Open by value:coding.code, value:coding.system
                                            Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


                                              ... code SΣ1..1CodeableConceptType of observation (code / type)
                                              Binding: LOINCCodes (preferred)
                                              SΣ1..1CodeableConceptOxygen saturation in Arterial blood
                                              Binding: VitalSigns (extensible): This identifies the vital sign result type.

                                              • Elements differ in short: 'Type of observation (code / type)' vs 'Oxygen saturation in Arterial blood'
                                              • Elements differ in definition: 'Describes what was observed. Sometimes this is called the observation "name".' vs 'Oxygen Saturation.'
                                              • Elements differ in comments: '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' vs 'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.'
                                              • Elements differ in requirements: 'Knowing what kind of observation is being made is essential to understanding the observation.' vs '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
                                              .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                .... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                                Slice: Unordered, Open by value:url
                                                0..*ExtensionAdditional content defined by implementations
                                                Slice: Unordered, Open by value:url
                                                  .... coding Σ0..*CodingCode defined by a terminology system
                                                  Σ0..*CodingCode defined by a terminology system
                                                  Slice: Unordered, Open by value:code, value:system
                                                    .... text Σ0..1stringPlain text representation of the conceptΣ0..1stringPlain text representation of the concept
                                                      ... subject SΣ1..1Reference(US Core Patient Profile)Who and/or what the observation is aboutSΣ1..1Reference(US Core Patient Profile)Who and/or what the observation is about
                                                        ... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                                        Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                                          ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                                            ... effective[x] SΣC0..1dateTime S, Period, Timing, instantClinically relevant time/time-period for observation
                                                            us-core-1: Datetime must be at least to day.
                                                            SΣC1..1dateTime, PeriodOften just a dateTime for Vital Signs
                                                            • Elements differ in short: 'Clinically relevant time/time-period for observation' vs 'Often just a dateTime for Vital Signs'
                                                            • Elements differ in definition: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time".' vs 'Often just a dateTime for Vital Signs.'
                                                            • Elements differ in comments: 'At least a date should be present unless this observation is a historical report.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the [Timing] datatype which allow the measurement to be tied to regular life events.'
                                                            • Element minimum cardinalities differ: '0' vs '1'
                                                            ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                                              ... performer SΣ0..*Reference(US Core Practitioner Profile S | US Core Organization Profile | US Core Patient Profile | PractitionerRole | US Core CareTeam Profile | US Core RelatedPerson Profile)Who is responsible for the observation
                                                              Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                              ... value[x] SΣC0..1Quantity S, CodeableConcept S, string S, boolean S, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual resultSΣC0..1QuantityVital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.
                                                              Slice: Unordered, Closed by type:$this
                                                              • Elements differ in short: 'Actual result' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
                                                              • Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
                                                              • Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).'
                                                              ... dataAbsentReason C0..1CodeableConceptWhy the result is missing
                                                              Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                              SC0..1CodeableConceptWhy the result is missing
                                                              Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                              • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                              ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                              Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                              S0..1CodeableConceptHigh, low, normal, etc.
                                                              Binding: Low Only Numeric Result Interpretation value set (extensible)
                                                              • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                              • Element maximum cardinalities differ: '2147483647' vs '1'
                                                              ... note 0..*AnnotationComments about the observation
                                                              0..*AnnotationComments about the observation
                                                                ... bodySite 0..1CodeableConceptObserved body part
                                                                Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

                                                                0..1CodeableConceptObserved body part
                                                                Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

                                                                  ... method 0..1CodeableConceptHow it was done
                                                                  Binding: ObservationMethods (example): Methods for simple observations.

                                                                  0..1CodeableConceptHow it was done
                                                                  Binding: ObservationMethods (example): Methods for simple observations.

                                                                    ... specimen 0..1Reference(Specimen)Specimen used for this observation0..1Reference(Specimen)Specimen used for this observation
                                                                      ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)(Measurement) Device
                                                                        ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                                                        C0..*BackboneElementProvides guide for interpretation
                                                                          .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                            .... extension 0..*ExtensionAdditional content defined by implementations
                                                                            0..*ExtensionAdditional content defined by implementations
                                                                              .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                              ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                .... low C0..1SimpleQuantityLow Range, if relevantC0..1SimpleQuantityLow Range, if relevant
                                                                                  .... high C0..1SimpleQuantityHigh Range, if relevantC0..1SimpleQuantityHigh Range, if relevant
                                                                                    .... type 0..1CodeableConceptReference range qualifier
                                                                                    Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

                                                                                    0..1CodeableConceptReference range qualifier
                                                                                    Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

                                                                                      .... appliesTo 0..*CodeableConceptReference range population
                                                                                      Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


                                                                                      0..*CodeableConceptReference range population
                                                                                      Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


                                                                                        .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                                          .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                                            ... hasMember Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
                                                                                            Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                                            • Elements differ in short: 'Related resource that belongs to the Observation group' vs 'Used when reporting vital signs panel components'
                                                                                            • Elements differ in definition: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' vs 'Used when reporting vital signs panel components.'
                                                                                            • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
                                                                                            ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
                                                                                            Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                                              ... component Σ0..*BackboneElementComponent results
                                                                                              SΣC0..*BackboneElementUsed when reporting systolic and diastolic blood pressure.
                                                                                              • Elements differ in short: 'Component results' vs 'Used when reporting systolic and diastolic blood pressure.'
                                                                                              • Elements differ in definition: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' vs 'Used when reporting systolic and diastolic blood pressure.'
                                                                                              • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                              .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                                                .... extension 0..*ExtensionAdditional content defined by implementations
                                                                                                0..*ExtensionAdditional content defined by implementations
                                                                                                  .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                                  ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                                    .... code Σ1..1CodeableConceptType of component observation (code / type)
                                                                                                    Binding: LOINCCodes (example): Codes identifying names of simple observations.

                                                                                                    SΣ1..1CodeableConceptType of component observation (code / type)
                                                                                                    Binding: VitalSigns (extensible): This identifies the vital sign result type.

                                                                                                    • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                                    • Elements differ in binding.description: 'Codes identifying names of simple observations.' vs 'This identifies the vital sign result type.'
                                                                                                    .... value[x] Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component resultSΣC0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Value recorded with UCUM
                                                                                                    Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs.

                                                                                                    • Elements differ in short: 'Actual component result' vs 'Vital Sign Value recorded with UCUM'
                                                                                                    • Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Sign Value recorded with UCUM.'
                                                                                                    • Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).'
                                                                                                    • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                                    .... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
                                                                                                    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                                    SC0..1CodeableConceptWhy the component result is missing
                                                                                                    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                                    • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                                    .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                                                    Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                                                                    0..*CodeableConceptHigh, low, normal, etc.
                                                                                                    Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                                                                      .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                                                      0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                                                        doco Documentation for this format