Left: | US Core Observation Imaging Result Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaging) |
Right: | Oxygen Saturation in Arterial blood, method not specified (http://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood) |
Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaging' vs 'http://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood' |
Error | StructureDefinition.version | Values for version differ: '5.0.1' vs '1.0.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreObservationImagingResultProfile' vs 'OxygenSaturationArterialBlood' |
Information | StructureDefinition.title | Values for title differ: 'US Core Observation Imaging Result Profile' vs 'Oxygen Saturation in Arterial blood, method not specified' |
Information | StructureDefinition.date | Values for date differ: '2022-04-20' vs '2022-09-12T00:45:08+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International - Clinical Information Modeling Initiative' |
Information | StructureDefinition.copyright | Values for copyright differ: 'Used by permission of HL7 International, all rights reserved Creative Commons License' vs 'Logica Health, all rights reserved Creative Commons License' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/Observation' vs 'http://hl7.org/fhir/StructureDefinition/oxygensat' |
Warning | Observation | Elements differ in short: 'Measurements and simple assertions' vs 'FHIR Oxygen Saturation Profile' |
Warning | Observation | Elements differ in definition: '\-' vs 'This profile defines how to represent Oxygen Saturation observations in FHIR using a standard LOINC code and UCUM units of measure.' |
Warning | Observation | Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.' |
Warning | Observation.code | Elements differ in short: 'Imaging Name' vs 'Oxygen saturation in Arterial blood' |
Warning | Observation.code | Elements differ in definition: 'The name of the imaging test performed on a patient. A LOINC **SHALL** be used if the concept is present in LOINC.' vs 'Oxygen Saturation.' |
Warning | Observation.code | Elements differ in comments: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' vs 'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.' |
Warning | Observation.code | Elements differ in requirements: 'Knowing what kind of observation is being made is essential to understanding the observation.' vs '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' |
Warning | Observation.effective[x] | Elements differ in short: 'Clinically relevant time/time-period for observation' vs 'Often just a dateTime for Vital Signs' |
Warning | Observation.effective[x] | Elements differ in definition: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' vs 'Often just a dateTime for Vital Signs.' |
Information | Observation.effective[x] | Element minimum cardinalities differ: '0' vs '1' |
Warning | Observation.value[x] | Elements differ in short: 'Result Value' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' |
Warning | Observation.value[x] | Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' |
Warning | Observation.value[x] | Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' |
Warning | Observation.interpretation | Elements differ in definition for mustSupport: 'false' vs 'true' |
Information | Observation.interpretation | Element maximum cardinalities differ: '2147483647' vs '1' |
Warning | Observation.hasMember | Elements differ in short: 'Related resource that belongs to the Observation group' vs 'Used when reporting vital signs panel components' |
Warning | Observation.hasMember | Elements differ in definition: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' vs 'Used when reporting vital signs panel components.' |
Error | Observation.hasMember | Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) |
Warning | Observation.component | Elements differ in short: 'Component results' vs 'Used when reporting systolic and diastolic blood pressure.' |
Warning | Observation.component | Elements differ in definition: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' vs 'Used when reporting systolic and diastolic blood pressure.' |
Warning | Observation.component | Elements differ in definition for mustSupport: 'false' vs 'true' |
Warning | Observation.component.code | Elements differ in definition for mustSupport: 'false' vs 'true' |
Warning | Observation.component.code | Elements differ in binding.description: 'Codes identifying names of simple observations.' vs 'This identifies the vital sign result type.' |
Warning | Observation.component.value[x] | Elements differ in short: 'Actual component result' vs 'Vital Sign Value recorded with UCUM' |
Warning | Observation.component.value[x] | Elements differ in definition: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Sign Value recorded with UCUM.' |
Warning | Observation.component.value[x] | Elements differ in requirements: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' |
Warning | Observation.component.value[x] | Elements differ in definition for mustSupport: 'false' vs 'true' |
Warning | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport: 'false' vs 'true' |
Name | Value | Comments | |
---|---|---|---|
abstract | false | ||
baseDefinition | http://hl7.org/fhir/StructureDefinition/Observation | http://hl7.org/fhir/StructureDefinition/oxygensat |
|
copyright | Used by permission of HL7 International, all rights reserved Creative Commons License | Logica Health, all rights reserved Creative Commons License |
|
date | 2022-04-20 | 2022-09-12T00:45:08+00:00 |
|
description | The US Core Observation Imaging Result Profile is based upon the core FHIR Observation Resource, and, along with the US Core DiagnosticReport Profile for Report and Note exchange, meets the U.S. Core Data for Interoperability (USCDI) v2 ‘Diagnostic Imaging’ requirements. To promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch retrieve structured and unstructured (narrative) components of diagnostic imaging test results for a patient. These observations include reasons, findings, and impressions. It provides the floor for standards development for specific uses cases. | A measurement of the percentage to which oxygen is bound to hemoglobin in arterial blood. |
|
experimental | |||
fhirVersion | 4.0.1 | ||
jurisdiction | |||
jurisdiction[0] | urn:iso:std:iso:3166#US | ||
kind | resource | ||
name | USCoreObservationImagingResultProfile | OxygenSaturationArterialBlood |
|
publisher | HL7 International - Cross-Group Projects | HL7 International - Clinical Information Modeling Initiative |
|
purpose | |||
status | active | ||
title | US Core Observation Imaging Result Profile | Oxygen Saturation in Arterial blood, method not specified |
|
type | Observation | ||
url | http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaging | http://hl7.org/fhir/us/vitals/StructureDefinition/oxygen-saturation-arterial-blood |
|
version | 5.0.1 | 1.0.0 |
|
Name | L Flags | L Card. | L Type | L Description & Constraints | R Flags | R Card. | L Type | L Description & Constraints | Comments | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | Observation | Measurements and simple assertions us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present | C | 0..* | observation-oxygensat | FHIR Oxygen Saturation Profile |
| ||||||||
id | Σ | 0..1 | string | Logical id of this artifact | Σ | 0..1 | id | Logical id of this artifact | |||||||||
meta | Σ | 0..1 | Meta | Metadata about the resource | Σ | 0..1 | Meta | Metadata about the resource | |||||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ?!Σ | 0..1 | uri | A set of rules under which this content was created | |||||||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||||||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||||||||
contained | 0..* | Resource | Contained, inline Resources | 0..* | Resource | Contained, inline Resources | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ?! | 0..* | Extension | Extensions that cannot be ignored | |||||||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | Σ | 0..* | Identifier | Business Identifier for observation | |||||||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | |||||||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | |||||||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required): Codes providing the status of an observation. | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) | |||||||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories. | |||||||||
code | SΣ | 1..1 | CodeableConcept | Imaging Name Binding: US Core Diagnosticreport Report And Note Codes (extensible) | SΣ | 1..1 | CodeableConcept | Oxygen saturation in Arterial blood Binding: VitalSigns (extensible): This identifies the vital sign result type. |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||||||||
coding | Σ | 0..* | Coding | Code defined by a terminology system | Σ | 0..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system | |||||||||
text | Σ | 0..1 | string | Plain text representation of the concept | Σ | 0..1 | string | Plain text representation of the concept | |||||||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | |||||||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | |||||||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | |||||||||
effective[x] | SΣC | 0..1 | dateTime S, Period, Timing, instant | Clinically relevant time/time-period for observation us-core-1: Datetime must be at least to day. | SΣC | 1..1 | dateTime, Period | Often just a dateTime for Vital Signs |
| ||||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | Σ | 0..1 | instant | Date/Time this version was made available | |||||||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | |||||||||
value[x] | SΣC | 0..1 | Quantity S, CodeableConcept S, string S, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Result Value us-core-3: SHALL use UCUM for coded quantity units. | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Closed by type:$this |
| ||||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | SC | 0..1 | CodeableConcept | Why the result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | |||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | S | 0..1 | CodeableConcept | High, low, normal, etc. Binding: Low Only Numeric Result Interpretation value set (extensible) |
| |||||||||
note | 0..* | Annotation | Comments about the observation | 0..* | Annotation | Comments about the observation | |||||||||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | 0..1 | CodeableConcept | Observed body part Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality. | |||||||||||
method | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | 0..1 | CodeableConcept | How it was done Binding: ObservationMethods (example): Methods for simple observations. | |||||||||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | 0..1 | Reference(Specimen) | Specimen used for this observation | |||||||||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||||||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation | C | 0..* | BackboneElement | Provides guide for interpretation | |||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
low | C | 0..1 | SimpleQuantity | Low Range, if relevant | C | 0..1 | SimpleQuantity | Low Range, if relevant | |||||||||
high | C | 0..1 | SimpleQuantity | High Range, if relevant | C | 0..1 | SimpleQuantity | High Range, if relevant | |||||||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | 0..1 | CodeableConcept | Reference range qualifier Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range. | |||||||||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | 0..* | CodeableConcept | Reference range population Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to. | |||||||||||
age | 0..1 | Range | Applicable age range, if relevant | 0..1 | Range | Applicable age range, if relevant | |||||||||||
text | 0..1 | string | Text based reference range in an observation | 0..1 | string | Text based reference range in an observation | |||||||||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components |
| ||||||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | |||||||||
component | Σ | 0..* | BackboneElement | Component results | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: LOINCCodes (example): Codes identifying names of simple observations. | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: VitalSigns (extensible): This identifies the vital sign result type. |
| ||||||||
value[x] | Σ | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result | SΣC | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Value recorded with UCUM Binding: VitalSignsUnits (required): Common UCUM units for recording Vital Signs. |
| ||||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
| ||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | 0..* | CodeableConcept | High, low, normal, etc. Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations. | |||||||||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||||||||
Documentation for this format |