Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature vs http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationPersonalCharacteristic

Left:US Core Body Temperature Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature)
Right:SDOHCC Observation Personal Characteristic (http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationPersonalCharacteristic)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperature' vs 'http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationPersonalCharacteristic'
ErrorStructureDefinition.versionValues for version differ: '6.1.0' vs '2.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreBodyTemperatureProfile' vs 'SDOHCCObservationPersonalCharacteristic'
InformationStructureDefinition.titleValues for title differ: 'US Core Body Temperature Profile' vs 'SDOHCC Observation Personal Characteristic'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2022-04-20' vs '2023-07-27T20:42:33+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International Patient Care WG'
WarningStructureDefinition.abstractValues for abstract differ: 'false' vs 'true'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Body Temperature Profile' vs 'Personal characteristic observation'
WarningObservationElements differ in definition: '\-' vs 'Defines constraints that represent the minimum requirement for personal characteristic observations which are observations that are usually self-attested but may be attested to on behalf of the subject (e.g., for a minor or incapable subject) and are generally only verifiable by the source of attestation (e.g., race, ethnicity, sexual orientation, gender identity and personal pronouns), but may sometimes be verifiable by someone other than the source of attestation (e.g., recorded sex).'
WarningObservationElements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
WarningObservation.extensionElements differ in short: 'Additional content defined by implementations' vs 'Extension'
WarningObservation.extensionElements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension'
WarningObservation.statusElements differ in short: '(USCDI) registered | preliminary | final | amended +' vs 'final | corrected | entered-in-error | unknown'
WarningObservation.statusElements differ in definition: 'The status of the result value.' vs 'The status of the observation value.'
WarningObservation.statusElements differ in requirements: 'Need to track the status of individual results. Some results are finalized before the whole report is finalized.' vs 'Further constrained to values that are relevant for personal characteristic observations.'
WarningObservation.categoryElements differ in short: '(USCDI) Classification of type of observation' vs 'Classification of type of observation'
WarningObservation.categoryElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.codeElements differ in short: '(USCDI) Body Temperature' vs 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' vs '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. NOTE: In LOINC, System Patient is used in the modeling of codes referenced by the Personal Characteristics profiles (e.g., 72826-1 Race OMB.1997, 69490-1 Ethnicity OMB.1997, 76691-5 Gender identity, 76690-7 Sexual orientation, 90778-2 Personal pronouns – Reported, and 99502-7 Recorded sex or gender). If the draft profiles are adopted, new LOINC codes without System Patient would be needed since these profiles can also be used to capture characteristics of a provider (using an extension) or a related person (using focus).'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.subjectElements differ in short: '(USCDI) Who and/or what the observation is about' vs 'Who and/or what the observation is about'
InformationObservation.subjectElement minimum cardinalities differ: '1' vs '0'
InformationObservation.focusElement maximum cardinalities differ: '2147483647' vs '1'
WarningObservation.effective[x]Elements differ in short: '(USCDI) Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
WarningObservation.effective[x]Elements differ in comments: 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing] datatype which allow the measurement to be tied to regular life events.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing] datatype which allow the measurement to be tied to regular life events. NOTE: dateTime is Must Support, but currently tooling does not support this.'
WarningObservation.effective[x]Elements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.effective[x]Element minimum cardinalities differ: '1' vs '0'
WarningObservation.performerElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.value[x]Elements differ in short: '(USCDI) Vital Signs Value' vs 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.dataAbsentReasonElements differ in short: '(USCDI) Why the result is missing' vs 'Why the result is missing'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.interpretationElement maximum cardinalities differ: '2147483647' vs '0'
InformationObservation.bodySiteElement maximum cardinalities differ: '1' vs '0'
InformationObservation.specimenElement maximum cardinalities differ: '1' vs '0'
InformationObservation.referenceRangeElement maximum cardinalities differ: '2147483647' vs '0'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' vs 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.derivedFromElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.componentElements differ in short: '(USCDI) Component observations' vs 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
WarningObservation.componentElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in short: '(USCDI) Type of component observation (code / type)' vs 'Type of component observation (code / type)'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: '(USCDI) Vital Sign Component Value' vs 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in short: '(USCDI) Why the component result is missing' vs 'Why the component result is missing'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalsetrue
  • Values Differ
.baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
  • Values Differ
.copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
  • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
.date2022-04-202023-07-27T20:42:33+00:00
  • Values Differ
.descriptionTo promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch body temperature observations with a standard LOINC code and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies which *additional* core elements, extensions, vocabularies, and value sets **SHALL** be present and constrains the way the elements are used when using the profile. It provides the floor for standards development for specific use cases.Defines constraints that represent the minimum requirement for personal characteristic observations which are observations that are usually self-attested but may be attested to on behalf of the subject and are generally only verifiable by the source of attestation (e.g., race, ethnicity, sexual orientation, gender identity and personal pronouns), but may sometimes be verifiable by someone other than the source of attestation (e.g., recorded sex). This profile is intended for draft use only. For further details on this profile see [Draft Specifications for Personal Characteristics](draft_specifications_for_personal_characteristics.html).
  • Values Differ
.experimentalfalse
  • Removed the item 'false'
.fhirVersion4.0.1
    .jurisdiction
      ..jurisdiction[0]urn:iso:std:iso:3166#US
        .kindresource
          .nameUSCoreBodyTemperatureProfileSDOHCCObservationPersonalCharacteristic
          • Values Differ
          .publisherHL7 International - Cross-Group ProjectsHL7 International Patient Care WG
          • Values Differ
          .purpose
            .statusactivedraft
            • Values Differ
            .titleUS Core Body Temperature ProfileSDOHCC Observation Personal Characteristic
            • Values Differ
            .typeObservation
              .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-body-temperaturehttp://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationPersonalCharacteristic
              • Values Differ
              .version6.1.02.1.0
              • Values Differ

              Structure

              NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
              .. Observation C0..*USCoreVitalSignsProfileUS Core Body Temperature Profile
              C0..*ObservationThis is an abstract profile. Child profiles: Observation, Observation, Observation, Observation, Observation, Observation
              Personal characteristic observation
              SDOH-Obs-1: Either subject or extension-Observation.subject must exist but not both
              SDOH-Obs-2: Focus is only allowed if subject is present
              SDOH-Obs-3: Must have either performer or derivedFrom
              • Elements differ in short: 'US Core Body Temperature Profile' vs 'Personal characteristic observation'
              • Elements differ in definition: '\-' vs 'Defines constraints that represent the minimum requirement for personal characteristic observations which are observations that are usually self-attested but may be attested to on behalf of the subject (e.g., for a minor or incapable subject) and are generally only verifiable by the source of attestation (e.g., race, ethnicity, sexual orientation, gender identity and personal pronouns), but may sometimes be verifiable by someone other than the source of attestation (e.g., recorded sex).'
              • Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
              ... id Σ0..1idLogical id of this artifactΣ0..1idLogical id of this artifact
                ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                  ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                    ... language 0..1codeLanguage of the resource content
                    Binding: ?? (preferred): A human language.

                    Additional BindingsPurpose
                    ??Max Binding
                    0..1codeLanguage of the resource content
                    Binding: ?? (preferred): A human language.

                    Additional BindingsPurpose
                    ??Max Binding
                      ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                        ... contained 0..*ResourceContained, inline Resources
                        0..*ResourceContained, inline Resources
                          ... extension 0..*ExtensionAdditional content defined by implementations
                          0..*ExtensionExtension
                          Slice: Unordered, Open by value:url
                          • Elements differ in short: 'Additional content defined by implementations' vs 'Extension'
                          • Elements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension'
                          ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                          ?!0..*ExtensionExtensions that cannot be ignored
                            ... identifier Σ0..*IdentifierBusiness Identifier for observation
                            Σ0..*IdentifierBusiness Identifier for observation
                              ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                              Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                  ... status ?!SΣ1..1code(USCDI) registered | preliminary | final | amended +
                                  Binding: ?? (required)
                                  ?!SΣ1..1codefinal | corrected | entered-in-error | unknown
                                  Binding: ?? (required)
                                  • Elements differ in short: '(USCDI) registered | preliminary | final | amended +' vs 'final | corrected | entered-in-error | unknown'
                                  • Elements differ in definition: 'The status of the result value.' vs 'The status of the observation value.'
                                  • Elements differ in requirements: 'Need to track the status of individual results. Some results are finalized before the whole report is finalized.' vs 'Further constrained to values that are relevant for personal characteristic observations.'
                                  ... Slices for category S1..*CodeableConcept(USCDI) Classification of type of observation
                                  Slice: Unordered, Open by value:coding.code, value:coding.system
                                  Binding: ?? (preferred): Codes for high level observation categories.


                                  1..*CodeableConceptClassification of type of observation
                                  Slice: Unordered, Open by value:$this
                                  Binding: ?? (preferred): Codes for high level observation categories.


                                  • Elements differ in short: '(USCDI) Classification of type of observation' vs 'Classification of type of observation'
                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                  ... code SΣ1..1CodeableConcept(USCDI) Body Temperature
                                  Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


                                  Required Pattern: {"coding":[{"system":"http://loinc.org","code":"8310-5"}]}
                                  SΣ1..1CodeableConceptType of observation (code / type)
                                  Binding: ?? (preferred): Codes identifying names of simple observations.

                                  • Elements differ in short: '(USCDI) Body Temperature' vs 'Type of observation (code / type)'
                                  • Elements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation "name".'
                                  • Elements differ in comments: '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' vs '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. NOTE: In LOINC, System Patient is used in the modeling of codes referenced by the Personal Characteristics profiles (e.g., 72826-1 Race OMB.1997, 69490-1 Ethnicity OMB.1997, 76691-5 Gender identity, 76690-7 Sexual orientation, 90778-2 Personal pronouns – Reported, and 99502-7 Recorded sex or gender). If the draft profiles are adopted, new LOINC codes without System Patient would be needed since these profiles can also be used to capture characteristics of a provider (using an extension) or a related person (using focus).'
                                  • Elements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
                                  • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                  ... subject SΣ1..1Reference(US Core Patient Profile)(USCDI) Who and/or what the observation is aboutSΣC0..1Reference(US Core Patient Profile)Who and/or what the observation is about
                                  • Elements differ in short: '(USCDI) Who and/or what the observation is about' vs 'Who and/or what the observation is about'
                                  • Element minimum cardinalities differ: '1' vs '0'
                                  ... focus ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                  ΣC0..1Reference(RelatedPerson)What the observation is about, when it is not about the subject of record
                                  • Element maximum cardinalities differ: '2147483647' vs '1'
                                  ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                    ... effective[x] SΣC1..1dateTime S, Period(USCDI) Often just a dateTime for Vital SignsΣ0..1dateTime, PeriodClinically relevant time/time-period for observation
                                    • Elements differ in short: '(USCDI) Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
                                    • Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
                                    • Elements differ in comments: 'At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the [Timing] datatype which allow the measurement to be tied to regular life events.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the [Timing] datatype which allow the measurement to be tied to regular life events. NOTE: dateTime is Must Support, but currently tooling does not support this.'
                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                    • Element minimum cardinalities differ: '1' vs '0'
                                    ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                      ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                      SΣC0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                      • Elements differ in definition for mustSupport: 'false' vs 'true'
                                      ... Slices for value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period(USCDI) Vital Signs Value
                                      Slice: Unordered, Open by type:$this
                                      Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                      SΣC0..1CodeableConceptActual result
                                      • Elements differ in short: '(USCDI) Vital Signs Value' vs 'Actual result'
                                      • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                      • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                      ... dataAbsentReason SC0..1CodeableConcept(USCDI) Why the result is missing
                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                      C0..1CodeableConceptWhy the result is missing
                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                      • Elements differ in short: '(USCDI) Why the result is missing' vs 'Why the result is missing'
                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                      ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                      0..0
                                      • Element maximum cardinalities differ: '2147483647' vs '0'
                                      ... note 0..*AnnotationComments about the observation
                                      0..*AnnotationComments about the observation
                                        ... bodySite 0..1CodeableConceptObserved body part
                                        Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                        0..0
                                        • Element maximum cardinalities differ: '1' vs '0'
                                        ... method 0..1CodeableConceptHow it was done
                                        Binding: ?? (example): Methods for simple observations.

                                        0..1CodeableConceptHow it was done
                                        Binding: ?? (example): Methods for simple observations.

                                          ... specimen 0..1Reference(Specimen)Specimen used for this observation0..0
                                          • Element maximum cardinalities differ: '1' vs '0'
                                          ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)(Measurement) Device
                                            ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                            C0..0
                                            • Element maximum cardinalities differ: '2147483647' vs '0'
                                            .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                              .... extension 0..*ExtensionAdditional content defined by implementations
                                              0..*ExtensionAdditional content defined by implementations
                                                .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                  .... low C0..1??Low Range, if relevantC0..1??Low Range, if relevant
                                                    .... high C0..1??High Range, if relevantC0..1??High Range, if relevant
                                                      .... type 0..1CodeableConceptReference range qualifier
                                                      Binding: ?? (preferred): Code for the meaning of a reference range.

                                                      0..1CodeableConceptReference range qualifier
                                                      Binding: ?? (preferred): Code for the meaning of a reference range.

                                                        .... appliesTo 0..*CodeableConceptReference range population
                                                        Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                        0..*CodeableConceptReference range population
                                                        Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                          .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                            .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                              ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                              Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
                                                              • Elements differ in short: 'Used when reporting vital signs panel components' vs 'Related resource that belongs to the Observation group'
                                                              • Elements differ in definition: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
                                                              • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                              ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                              SΣC0..*Reference(DocumentReference | QuestionnaireResponse | Observation)Related measurements the observation is made from
                                                              • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                              ... component SΣC0..*BackboneElement(USCDI) Component observations
                                                              Σ0..*BackboneElementComponent results
                                                              • Elements differ in short: '(USCDI) Component observations' vs 'Component results'
                                                              • Elements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                              .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                .... extension 0..*ExtensionAdditional content defined by implementations
                                                                0..*ExtensionAdditional content defined by implementations
                                                                  .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                  ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                    .... code SΣ1..1CodeableConcept(USCDI) Type of component observation (code / type)
                                                                    Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                                                    Σ1..1CodeableConceptType of component observation (code / type)
                                                                    Binding: ?? (example): Codes identifying names of simple observations.

                                                                    • Elements differ in short: '(USCDI) Type of component observation (code / type)' vs 'Type of component observation (code / type)'
                                                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                    • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                                                    .... value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period(USCDI) Vital Sign Component Value
                                                                    Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                                    Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                                    • Elements differ in short: '(USCDI) Vital Sign Component Value' vs 'Actual component result'
                                                                    • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                                    • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                    .... dataAbsentReason SC0..1CodeableConcept(USCDI) Why the component result is missing
                                                                    Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                    C0..1CodeableConceptWhy the component result is missing
                                                                    Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                    • Elements differ in short: '(USCDI) Why the component result is missing' vs 'Why the component result is missing'
                                                                    • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                    .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                    Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                    0..*CodeableConceptHigh, low, normal, etc.
                                                                    Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                      .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                      0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                        doco Documentation for this format