Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationScreeningResponse

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:SDOHCC Observation Screening Response (http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationScreeningResponse)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationScreeningResponse'
ErrorStructureDefinition.versionValues for version differ: '4.0.0' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'SDOHCCObservationScreeningResponse'
InformationStructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'SDOHCC Observation Screening Response'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2020-11-18' vs '2021-08-05T20:07:39+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International - Patient Care WG'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Pulse Oximetry Profile' 'SDOH screening questionnaire observations'
WarningObservationElements differ in definition: 'Defines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.' 'For Observations derived from SDOH screening surveys/questionnaires.'
WarningObservationElements differ in comments: 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.' 'Used for simple observations such as education status, food insecurity observations, etc. This profile allows the representation of SDOH observations based on SDOH screening questionnaire responses (which can also be represented using SDC QuestionnaireResponse). Many of the SDOHCC profiles reference one another. One flow supported by this IG is that QuestionnaireResponses result in Observations that can be used as evidence for Conditions that can lead to Goals, ServiceRequests and Procedures. However, alternatives paths are also possible.'
WarningObservation.statusElements differ in short: 'registered | preliminary | final | amended +' 'final | corrected | entered-in-error | unknown'
WarningObservation.statusElements differ in definition: 'The status of the result value.' 'The status of the observation value.'
WarningObservation.statusElements differ in requirements: 'Need to track the status of individual results. Some results are finalized before the whole report is finalized.' 'Further constrained to values that are relevant for SDOH.'
WarningObservation.categoryElements differ in requirements: 'Used for filtering what observations are retrieved and displayed.' 'To identify that an SDOH screening response observation is derived from an SDOH questionnaire, the “social-history” and “survey” codes are required.'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Oxygen Saturation by Pulse Oximetry' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood).' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. For SDOH questions represented in LOINC that specify “check all that apply”, the LOINC question should be used for Observation.code and for Observation.component.code. For “check all that apply” questions, the answers (regardless of whether one or more are selected) should only be represented using Observation.component.value and Observation.value should be empty. As the Gravity Project continues to refine content for the SDOH categories (e.g., food, housing, transportation, etc.), this value set will be refined to codes that pertain to SDOH categories.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' 'Knowing what kind of observation is being made is essential to understanding the observation. The Gravity implemenation guide restricts questionnaire/survey observations to LOINC to move the industry to the use of LOINC panels/surveys (structures that are not available in other terminology systems) to standardize the coding of SDOH related risk assessment instruments. In addition, USCDI and US Core have standardized on the use of LOINC to represent Observations in general.'
ErrorObservation.code.codingElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.subjectElements differ in comments: 'One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.' 'Cardinality is 1..1.'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'.'
WarningObservation.effective[x]Elements differ in comments: 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing] datatype which allow the measurement to be tied to regular life events.' 'At least a date should be present unless this observation is a historical report.'
WarningObservation.performerElements differ in requirements: 'May give a degree of confidence in the observation and also indicates where follow-up questions should be directed.' 'Some questions on an SDOH screening questionnaire are not answered directly (e.g., asserted) by the individual completing the questionnaire. Rather, the answer to some questions (e.g., the Hunger Vital Sign 88124-3 “Food insecurity risk”) may be derived from answers to one or more other questions. For a Screening Response Observation that is derived, as opposed to answered directly, Observation.performer should not be specified and Observation.derivedFrom should reference the relevant Screening Response Observation(s).'
ErrorObservation.performerElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.performerType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Practitioner], CanonicalType[http://hl7.org/fhir/StructureDefinition/PractitionerRole], CanonicalType[http://hl7.org/fhir/StructureDefinition/Organization], CanonicalType[http://hl7.org/fhir/StructureDefinition/CareTeam], CanonicalType[http://hl7.org/fhir/StructureDefinition/Patient], CanonicalType[http://hl7.org/fhir/StructureDefinition/RelatedPerson]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/RelatedPerson], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam]])
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.dataAbsentReasonElements differ in comments: 'Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be 'detected', 'not detected', 'inconclusive', or 'specimen unsatisfactory'. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code 'error' could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.' ''Null' or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For a given LOINC question, if the LOINC answer list includes concepts such as 'unknown' or 'not available', they should be used for Observation.value. Where these concepts are not part of the value set for Observation.value, the Observation.dataAbsentReason can be used if necessary and appropriate.'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' 'Used when an observation is a group observation (e.g., the LOINC 88121-9 Hunger Vital Sign [HVS] panel) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
ErrorObservation.derivedFromElements differ in definition for mustSupport: 'false' 'true'
WarningObservation.componentElements differ in short: 'Used when reporting flow rates or oxygen concentration.' 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting flow rates or oxygen concentration.' 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples: 1) Individuals may be multiracial. Component is used to capture one or more races. 2) “Material hardship” can be assessed based on a number of factors (adequate food, clothing, utilities, etc.). One, or all, of which can be captured using Component.'
WarningObservation.componentElements differ in comments: 'For a discussion on the ways Observations can be assembled in groups together see [Notes] below.' 'For a discussion on the ways Observations can be assembled in groups together see [Notes] below. For SDOH questions represented in LOINC that specify “check all that apply”, the LOINC question should be used for Observation.code and for Observation.component.code. For “check all that apply” questions, the answers (regardless of whether one or more are selected) should only be represented using Observation.component.value and Observation.value should be empty.'
ErrorObservation.componentElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.component.codeElements differ in comments: '*All* code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.' '*All* code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. As the Gravity Project continues to refine content for the SDOH categories (e.g., food, housing, transportation, etc.), this value set will be refined to codes that pertain to SDOH categories.'
WarningObservation.component.codeElements differ in requirements: 'Knowing what kind of observation is being made is essential to understanding the observation.' 'Knowing what kind of observation is being made is essential to understanding the observation. LOINC codes are required because Gravity intends to use only LOINC encoded Questionnaires to generate QuestionnaireResponses which, in turn, will generate Screening Response Observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.dataAbsentReasonElements differ in comments: ''Null' or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be 'detected', 'not detected', 'inconclusive', or 'test not done'. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code 'error' could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.' ''Null' or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For a given 'check all that apply' LOINC question, if the LOINC answer list includes concepts such as 'unknown' or 'not available', they should be used for Observation.component.value. Where these concepts are not part of the value set for Observation.component.value, the Observation.component.dataAbsentReason can be used if necessary and appropriate.'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2020-11-182021-08-05T20:07:39+00:00
    • Values Differ
    .descriptionDefines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.This profile constrains the Observation resource for observations that represent question and answer pairs from SDOH screening instruments that are represented in LOINC. The Cross-Group Projects work group granted an exception to US Core on 12/03/2020 - Jira ticket 29795.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCorePulseOximetryProfileSDOHCCObservationScreeningResponse
            • Values Differ
            .publisherHL7 International - US Realm Steering CommitteeHL7 International - Patient Care WG
            • Values Differ
            .purpose
              .statusactivedraft
              • Values Differ
              .titleUS Core Pulse Oximetry ProfileSDOHCC Observation Screening Response
              • Values Differ
              .typeObservation
                .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/sdoh-clinicalcare/StructureDefinition/SDOHCC-ObservationScreeningResponse
                • Values Differ
                .version4.0.01.0.0
                • Values Differ

                Structure

                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                .. Observation II
                • Elements differ in short: "US Core Pulse Oximetry Profile" "SDOH screening questionnaire observations"
                • Elements differ in definition: "Defines constraints on the Observation resource to represent inspired O2 by pulse oximetry and inspired oxygen concentration observations with a standard LOINC codes and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile." "For Observations derived from SDOH screening surveys/questionnaires."
                • Elements differ in comments: "Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc." "Used for simple observations such as education status, food insecurity observations, etc. This profile allows the representation of SDOH observations based on SDOH screening questionnaire responses (which can also be represented using SDC QuestionnaireResponse). Many of the SDOHCC profiles reference one another. One flow supported by this IG is that QuestionnaireResponses result in Observations that can be used as evidence for Conditions that can lead to Goals, ServiceRequests and Procedures. However, alternatives paths are also possible."
                ... id ΣΣ
                  ... meta ΣΣ
                    ... implicitRules ?!Σ?!Σ
                      ... language
                        ... text
                          ... contained
                            ... extension ExtensionExtension
                              ... modifierExtension ?!?!
                                ... identifier ΣΣ
                                  ... basedOn ΣΣ
                                    ... partOf ΣΣ
                                      ... status ?!SΣ?!SΣ
                                      • Elements differ in short: "registered | preliminary | final | amended +" "final | corrected | entered-in-error | unknown"
                                      • Elements differ in definition: "The status of the result value." "The status of the observation value."
                                      • Elements differ in requirements: "Need to track the status of individual results. Some results are finalized before the whole report is finalized." "Further constrained to values that are relevant for SDOH."
                                      ... Slices for category S
                                      • Elements differ in requirements: "Used for filtering what observations are retrieved and displayed." "To identify that an SDOH screening response observation is derived from an SDOH questionnaire, the “social-history” and “survey” codes are required."
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... code SΣSΣ
                                      • Elements differ in short: "Oxygen Saturation by Pulse Oximetry" "Type of observation (code / type)"
                                      • Elements differ in definition: "Coded Responses from C-CDA Vital Sign Results." "Describes what was observed. Sometimes this is called the observation "name"."
                                      • Elements differ in comments: "The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood)." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. For SDOH questions represented in LOINC that specify “check all that apply”, the LOINC question should be used for Observation.code and for Observation.component.code. For “check all that apply” questions, the answers (regardless of whether one or more are selected) should only be represented using Observation.component.value and Observation.value should be empty. As the Gravity Project continues to refine content for the SDOH categories (e.g., food, housing, transportation, etc.), this value set will be refined to codes that pertain to SDOH categories."
                                      • Elements differ in requirements: "5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301)." "Knowing what kind of observation is being made is essential to understanding the observation. The Gravity implemenation guide restricts questionnaire/survey observations to LOINC to move the industry to the use of LOINC panels/surveys (structures that are not available in other terminology systems) to standardize the coding of SDOH related risk assessment instruments. In addition, USCDI and US Core have standardized on the use of LOINC to represent Observations in general."
                                      .... id
                                        .... Slices for extension ExtensionExtension
                                          .... Slices for coding SΣΣ
                                          • Elements differ in definition for mustSupport: "true" "false"
                                          .... text ΣΣ
                                            ... subject SΣSΣ
                                            • Elements differ in comments: "One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated." "Cardinality is 1..1."
                                            ... focus ΣΣ
                                              ... encounter ΣΣ
                                                ... effective[x] SΣISΣ
                                                • Elements differ in short: "Often just a dateTime for Vital Signs" "Clinically relevant time/time-period for observation"
                                                • Elements differ in definition: "Often just a dateTime for Vital Signs." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time"."
                                                • Elements differ in comments: "At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the [Timing] datatype which allow the measurement to be tied to regular life events." "At least a date should be present unless this observation is a historical report."
                                                ... issued ΣΣ
                                                  ... performer ΣSΣ
                                                  • Elements differ in requirements: "May give a degree of confidence in the observation and also indicates where follow-up questions should be directed." "Some questions on an SDOH screening questionnaire are not answered directly (e.g., asserted) by the individual completing the questionnaire. Rather, the answer to some questions (e.g., the Hunger Vital Sign 88124-3 “Food insecurity risk”) may be derived from answers to one or more other questions. For a Screening Response Observation that is derived, as opposed to answered directly, Observation.performer should not be specified and Observation.derivedFrom should reference the relevant Screening Response Observation(s)."
                                                  • Elements differ in definition for mustSupport: "false" "true"
                                                  • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Practitioner], CanonicalType[http://hl7.org/fhir/StructureDefinition/PractitionerRole], CanonicalType[http://hl7.org/fhir/StructureDefinition/Organization], CanonicalType[http://hl7.org/fhir/StructureDefinition/CareTeam], CanonicalType[http://hl7.org/fhir/StructureDefinition/Patient], CanonicalType[http://hl7.org/fhir/StructureDefinition/RelatedPerson]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/RelatedPerson], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-patient], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitioner], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-practitionerrole], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-organization], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-careteam]])
                                                  ... value[x] SΣISΣI
                                                  • Elements differ in short: "Vital Signs Value" "Actual result"
                                                  • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type." "The information determined as a result of making the observation, if the information has a simple value."
                                                  • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                  ... dataAbsentReason SISI
                                                  • Elements differ in comments: "Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values." ""Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For a given LOINC question, if the LOINC answer list includes concepts such as 'unknown' or 'not available', they should be used for Observation.value. Where these concepts are not part of the value set for Observation.value, the Observation.dataAbsentReason can be used if necessary and appropriate."
                                                  ... interpretation
                                                    ... note
                                                      ... bodySite
                                                        ... method
                                                          ... specimen
                                                            ... device
                                                              ... referenceRange II
                                                                .... id
                                                                  .... extension ExtensionExtension
                                                                    .... modifierExtension ?!Σ?!Σ
                                                                      .... low II
                                                                        .... high II
                                                                          .... type
                                                                            .... appliesTo
                                                                              .... age
                                                                                .... text
                                                                                  ... hasMember ΣΣ
                                                                                  • Elements differ in short: "Used when reporting vital signs panel components" "Related resource that belongs to the Observation group"
                                                                                  • Elements differ in definition: "Used when reporting vital signs panel components." "Used when an observation is a group observation (e.g., the LOINC 88121-9 Hunger Vital Sign [HVS] panel) that includes the target as a member of the group."
                                                                                  • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                                  ... derivedFrom ΣSΣ
                                                                                  • Elements differ in definition for mustSupport: "false" "true"
                                                                                  ... Slices for component SΣIΣ
                                                                                  • Elements differ in short: "Used when reporting flow rates or oxygen concentration." "Component results"
                                                                                  • Elements differ in definition: "Used when reporting flow rates or oxygen concentration." "Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples: 1) Individuals may be multiracial. Component is used to capture one or more races. 2) “Material hardship” can be assessed based on a number of factors (adequate food, clothing, utilities, etc.). One, or all, of which can be captured using Component."
                                                                                  • Elements differ in comments: "For a discussion on the ways Observations can be assembled in groups together see [Notes] below." "For a discussion on the ways Observations can be assembled in groups together see [Notes] below. For SDOH questions represented in LOINC that specify “check all that apply”, the LOINC question should be used for Observation.code and for Observation.component.code. For “check all that apply” questions, the answers (regardless of whether one or more are selected) should only be represented using Observation.component.value and Observation.value should be empty."
                                                                                  • Elements differ in definition for mustSupport: "true" "false"
                                                                                  .... id
                                                                                    .... extension ExtensionExtension
                                                                                      .... modifierExtension ?!Σ?!Σ
                                                                                        .... code SΣSΣ
                                                                                        • Elements differ in comments: "*All* code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation." "*All* code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. As the Gravity Project continues to refine content for the SDOH categories (e.g., food, housing, transportation, etc.), this value set will be refined to codes that pertain to SDOH categories."
                                                                                        • Elements differ in requirements: "Knowing what kind of observation is being made is essential to understanding the observation." "Knowing what kind of observation is being made is essential to understanding the observation. LOINC codes are required because Gravity intends to use only LOINC encoded Questionnaires to generate QuestionnaireResponses which, in turn, will generate Screening Response Observations."
                                                                                        .... value[x] SΣISΣ
                                                                                        • Elements differ in short: "Vital Sign Component Value" "Actual component result"
                                                                                        • Elements differ in definition: "Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept." "The information determined as a result of making the observation, if the information has a simple value."
                                                                                        • Elements differ in requirements: "9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305)." "An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations."
                                                                                        .... dataAbsentReason SISI
                                                                                        • Elements differ in comments: ""Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values." ""Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For a given "check all that apply" LOINC question, if the LOINC answer list includes concepts such as 'unknown' or 'not available', they should be used for Observation.component.value. Where these concepts are not part of the value set for Observation.component.value, the Observation.component.dataAbsentReason can be used if necessary and appropriate."
                                                                                        .... interpretation
                                                                                          .... referenceRange

                                                                                            doco Documentation for this format