QI-Core Implementation Guide
5.0.0 - STU5 United States of America flag

This page is part of the Quality Improvement Core Framework (v5.0.0: STU5 (v5.0.0)) based on FHIR R4. The current version which supercedes this version is 4.1.1. For a full list of available versions, see the Directory of published versions

: ProcedureNotDone with valueset example - JSON Representation

Raw json | Download


{
  "resourceType" : "Procedure",
  "id" : "negation-example",
  "meta" : {
    "profile" : [
      "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-procedurenotdone"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Procedure</b><a name=\"negation-example\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Procedure &quot;negation-example&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-qicore-procedurenotdone.html\">QICore Procedure Not Done</a></p></div><p><b>QICore Not Done Recorded</b>: 2013-04-05 10:30:00-0400</p><p><b>status</b>: not-done</p><p><b>statusReason</b>: Complication of medical care (disorder) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#35688006)</span></p><p><b>code</b>: Not Done Value Set: Intermittent pneumatic compression devices (IPC) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (Not done value set: <a href=\"http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214\">http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214</a>)</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Patient/example</a> &quot; CHALMERS&quot;</p><p><b>encounter</b>: <a href=\"Encounter-example.html\">Encounter/example</a></p><p><b>performed</b>: </p><h3>Performers</h3><table class=\"grid\"><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a href=\"Practitioner-example.html\">Practitioner/example: Dr Cecil Surgeon</a> &quot; CAREFUL&quot;</td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-recorded",
      "valueDateTime" : "2013-04-05T10:30:00-04:00"
    }
  ],
  "status" : "not-done",
  "statusReason" : {
    "coding" : [
      {
        "system" : "http://snomed.info/sct",
        "code" : "35688006",
        "display" : "Complication of medical care (disorder)"
      }
    ]
  },
  "code" : {
    "extension" : [
      {
        "url" : "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-notDoneValueSet",
        "valueCanonical" : "http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214"
      }
    ],
    "text" : "Not Done Value Set: Intermittent pneumatic compression devices (IPC)"
  },
  "subject" : {
    "reference" : "Patient/example"
  },
  "encounter" : {
    "reference" : "Encounter/example"
  },
  "_performedDateTime" : {
    "extension" : [
      {
        "url" : "http://hl7.org/fhir/StructureDefinition/data-absent-reason",
        "valueCode" : "not-performed"
      }
    ]
  },
  "performer" : [
    {
      "actor" : {
        "reference" : "Practitioner/example",
        "display" : "Dr Cecil Surgeon"
      }
    }
  ]
}