This page is part of the Quality Improvement Core Framework (v5.0.0: STU5 (v5.0.0)) based on FHIR R4. The current version which supercedes this version is 4.1.1. For a full list of available versions, see the Directory of published versions
@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <https://loinc.org/rdf/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Observation ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "example"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-observation"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-observation> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "extensions" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"example\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation "example" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-qicore-observation.html\">QICore Observation</a></p></div><p><b>bodyPosition</b>: Sitting position (finding) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#33586001)</span></p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Hemoglobin [Mass/volume] in Venous blood <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#30350-3)</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Patient/example</a> " CHALMERS"</p><p><b>encounter</b>: <a href=\"Encounter-example.html\">Encounter/example</a></p><p><b>effective</b>: 2013-04-02 10:30:10+0100 --> 2013-04-05 10:30:10+0100</p><p><b>issued</b>: Apr 3, 2013, 2:30:10 PM</p><p><b>value</b>: 7.2 g/dl<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code g/dL = 'g/dL')</span></p><p><b>interpretation</b>: Below low normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0078/index.html\">v2 ABNORMAL FLAGS</a>#L "Low")</span></p><p><b>bodySite</b>: Superficial forearm vein <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#308046002)</span></p><p><b>method</b>: Injection to forearm <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#120220003)</span></p><p><b>specimen</b>: <a href=\"Specimen-example.html\">Specimen/example</a></p><p><b>derivedFrom</b>: <a href=\"Observation-example.html\">Observation/example</a></p><blockquote><p><b>component</b></p><p><b>code</b>: Systolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8480-6; <a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#271649006; clinical-codes#bp-s "Systolic Blood pressure")</span></p><p><b>value</b>: 107 mmHg<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mm[Hg] = 'mm[Hg]')</span></p><p><b>interpretation</b>: Normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0078/index.html\">v2 ABNORMAL FLAGS</a>#N "normal")</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8462-4)</span></p><p><b>value</b>: 60 mmHg<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code mm[Hg] = 'mm[Hg]')</span></p><p><b>interpretation</b>: Below low normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0078/index.html\">v2 ABNORMAL FLAGS</a>#L "low")</span></p></blockquote></div>"
] ; #
fhir:extension ( [
fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/observation-bodyPosition"^^xsd:anyURI ] ;
fhir:value [
a fhir:CodeableConcept ;
( fhir:coding [
a sct:33586001 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "33586001" ] ;
fhir:display [ fhir:v "Sitting position (finding)" ] ] ) ]
] ) ; #
fhir:status [ fhir:v "final"] ; #
fhir:category ( [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/observation-category"^^xsd:anyURI ] ;
fhir:code [ fhir:v "vital-signs" ] ;
fhir:display [ fhir:v "Vital Signs" ] ] )
] ) ; #
fhir:code [
( fhir:coding [
a loinc:30350-3 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "30350-3" ] ;
fhir:display [ fhir:v "Hemoglobin [Mass/volume] in Venous blood" ] ] )
] ; #
fhir:subject [
fhir:reference [ fhir:v "Patient/example" ]
] ; #
fhir:encounter [
fhir:reference [ fhir:v "Encounter/example" ]
] ; #
fhir:effective [
a fhir:Period ;
fhir:start [ fhir:v "2013-04-02T10:30:10+01:00"^^xsd:dateTime ] ;
fhir:end [ fhir:v "2013-04-05T10:30:10+01:00"^^xsd:dateTime ]
] ; #
fhir:issued [ fhir:v "2013-04-03T15:30:10+01:00"^^xsd:dateTime] ; #
fhir:value [
a fhir:Quantity ;
fhir:value [ fhir:v "7.2"^^xsd:decimal ] ;
fhir:unit [ fhir:v "g/dl" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "g/dL" ]
] ; #
fhir:interpretation ( [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0078"^^xsd:anyURI ] ;
fhir:code [ fhir:v "L" ] ;
fhir:display [ fhir:v "Low" ] ] ) ;
fhir:text [ fhir:v "Below low normal" ]
] ) ; #
fhir:bodySite [
( fhir:coding [
a sct:308046002 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "308046002" ] ;
fhir:display [ fhir:v "Superficial forearm vein" ] ] )
] ; #
fhir:method [
( fhir:coding [
a sct:120220003 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "120220003" ] ;
fhir:display [ fhir:v "Injection to forearm" ] ] )
] ; #
fhir:specimen [
fhir:reference [ fhir:v "Specimen/example" ]
] ; #
fhir:derivedFrom ( [
fhir:reference [ fhir:v "Observation/example" ]
] ) ; #
fhir:component ( [
fhir:code [
( fhir:coding [
a loinc:8480-6 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "8480-6" ] ;
fhir:display [ fhir:v "Systolic blood pressure" ] ] [
a sct:271649006 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "271649006" ] ;
fhir:display [ fhir:v "Systolic blood pressure" ] ] [
fhir:system [ fhir:v "http://example.org/devices/clinical-codes"^^xsd:anyURI ] ;
fhir:code [ fhir:v "bp-s" ] ;
fhir:display [ fhir:v "Systolic Blood pressure" ] ] ) # LOINC -code ] ; # \n Observations are often coded in multiple code systems.\n - LOINC provides a very specific code (though not more specific in this particular\n case)\n - snomed provides a clinically relevant code that is usually less granular\n than LOINC\n - the source system provides its own code, which may be less or more granular\n than LOINC\n\nthis is shown here to demonstrate the concept of translations within the codeableConcept\n datatype. The diastolic code below only has a LOINC code\n
fhir:value [
a fhir:Quantity ;
fhir:value [ fhir:v "107"^^xsd:decimal ] ;
fhir:unit [ fhir:v "mmHg" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "mm[Hg]" ] ] ;
( fhir:interpretation [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0078"^^xsd:anyURI ] ;
fhir:code [ fhir:v "N" ] ;
fhir:display [ fhir:v "normal" ] ] ) ;
fhir:text [ fhir:v "Normal" ] ] ) # an interpretation for the individual composite observation
] [
fhir:code [
( fhir:coding [
a loinc:8462-4 ;
fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "8462-4" ] ;
fhir:display [ fhir:v "Diastolic blood pressure" ] ] ) ] ; # this codes only has a LOINC code
fhir:value [
a fhir:Quantity ;
fhir:value [ fhir:v "60"^^xsd:decimal ] ;
fhir:unit [ fhir:v "mmHg" ] ;
fhir:system [ fhir:v "http://unitsofmeasure.org"^^xsd:anyURI ] ;
fhir:code [ fhir:v "mm[Hg]" ] ] ;
( fhir:interpretation [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0078"^^xsd:anyURI ] ;
fhir:code [ fhir:v "L" ] ;
fhir:display [ fhir:v "low" ] ] ) ;
fhir:text [ fhir:v "Below low normal" ] ] ) # an interpretation for the individual composite observation
] ) . # Should have a refrange as well
IG © 2019+ http://www.hl7.org/Special/committees/cqi/index.cfm. Package hl7.fhir.us.qicore#5.0.0 based on FHIR 4.0.1. Generated 2023-04-04
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change