QI-Core Implementation Guide
5.0.0 - STU5 United States of America flag

This page is part of the Quality Improvement Core Framework (v5.0.0: STU5 (v5.0.0)) based on FHIR R4. The current version which supercedes this version is 4.1.1. For a full list of available versions, see the Directory of published versions

: DeviceRequest negation with code example - JSON Representation

Raw json | Download


{
  "resourceType" : "DeviceRequest",
  "id" : "negation-with-code-example",
  "meta" : {
    "profile" : [
      "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-devicenotrequested"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: DeviceRequest</b><a name=\"negation-with-code-example\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource DeviceRequest &quot;negation-with-code-example&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-qicore-devicenotrequested.html\">QICore Device Not Requested</a></p></div><p><b>QICore Do Not Perform Reason</b>: Not indicated (qualifier value) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#410534003)</span></p><blockquote><p><b>modifierExtension[http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform]</b></p></blockquote><p><b>status</b>: completed</p><p><b>intent</b>: original-order</p><p><b>code</b>: Venous foot pump, device (physical object) <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT[US]</a>#442023007)</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Patient/example</a> &quot; CHALMERS&quot;</p><p><b>authoredOn</b>: 2016-04-05 09:20:00-0400</p></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-doNotPerformReason",
      "valueCodeableConcept" : {
        "coding" : [
          {
            "system" : "http://snomed.info/sct",
            "code" : "410534003",
            "display" : "Not indicated (qualifier value)"
          }
        ]
      }
    }
  ],
  "modifierExtension" : [
    {
      "url" : "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform",
      "valueBoolean" : true
    }
  ],
  "status" : "completed",
  "intent" : "original-order",
  "codeCodeableConcept" : {
    "coding" : [
      {
        "system" : "http://snomed.info/sct",
        "version" : "http://snomed.info/sct/731000124108",
        "code" : "442023007",
        "display" : "Venous foot pump, device (physical object)"
      }
    ]
  },
  "subject" : {
    "reference" : "Patient/example"
  },
  "authoredOn" : "2016-04-05T09:20:00-04:00"
}