QI-Core Implementation Guide
4.1.1 - STU 4.1.1
US
This page is part of the Quality Improvement Core Framework (v4.1.1: STU 4) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<ServiceRequest xmlns="http://hl7.org/fhir">
<id value="negation-example"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative</b></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource "negation-example" </p></div><p><b>QICoreDoNotPerformReason</b>: Procedure discontinued (situation) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#416406003)</span></p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>priority</b>: urgent</p><p><b>doNotPerform</b>: true</p><p><b>code</b>: Not Done Value Set: Intermittent pneumatic compression devices (IPC) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (Not done value set: <a href="http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214">http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214</a>)</span></p><p><b>subject</b>: <a href="Patient-example.html">Patient/example</a> " CHALMERS"</p><p><b>encounter</b>: <a href="Encounter-example.html">Encounter/example</a></p><p><b>occurrence</b>: 2013-04-05</p><p><b>authoredOn</b>: 2013-04-04</p><p><b>bodySite</b>: Appendix structure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#66754008)</span></p></div>
</text>
<extension
url="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-doNotPerformReason">
<valueCodeableConcept>
<coding>
<system value="http://snomed.info/sct"/>
<code value="416406003"/>
<display value="Procedure discontinued (situation)"/>
</coding>
</valueCodeableConcept>
</extension>
<status value="completed"/>
<intent value="order"/>
<priority value="urgent"/>
<doNotPerform value="true"/>
<code>
<extension
url="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-notDoneValueSet">
<valueCanonical
value="http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214"/>
</extension>
<text
value="Not Done Value Set: Intermittent pneumatic compression devices (IPC)"/>
</code>
<subject>
<reference value="Patient/example"/>
</subject>
<encounter>
<reference value="Encounter/example"/>
</encounter>
<occurrenceDateTime value="2013-04-05"/>
<authoredOn value="2013-04-04"/>
<bodySite>
<coding>
<system value="http://snomed.info/sct"/>
<code value="66754008"/>
<display value="Appendix structure"/>
</coding>
</bodySite>
</ServiceRequest>