This page is part of the Quality Improvement Core Framework (v2.0.0: STU 2) based on FHIR R3. The current version which supercedes this version is 4.1.1. For a full list of available versions, see the Directory of published versions

Device qicore-device-example

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "qicore-device-example"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n      <p>\n        <strong>id</strong>: example\n      </p>\n      <p>\n        <strong>identifier</strong>: 345675, Serial Number = AMID-342135-8464\n      </p>\n      <p>\n        <strong>status</strong>: active\n      </p>\n      <p>\n        <strong>type</strong>: ECG { SNOMED CT code '86184003' = 'Electrocardiographic monitor and recorder' })\n      </p>\n      <p>\n        <strong>lotNumber</strong>: 43453424\n      </p>\n      <p>\n        <strong>manufacturer</strong>: Acme Devices, Inc\n      </p>\n      <p>\n        <strong>model</strong>: AB 45-J\n      </p>\n      <p>\n        <strong>contact</strong>: phone ext 4352\n      </p>\n      <blockquote>\n        <p><strong>note</strong></p>\n        <p>\n          <strong>authorReference</strong>:    \n          <a href=\"Practitioner-qicore-practitioner-example.html\">Practitioner/example</a>\n        </p>\n        <p>\n          <strong>time</strong>: 06/28/2015\n        </p>\n        <p>\n          <strong>text</strong>: QA Checked\n        </p>\n      </blockquote>\n    </div>"
  ];
  fhir:Device.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "http://goodcare.org/devices/id" ];
     fhir:Identifier.value [ fhir:value "345675" ]
  ], [
     fhir:index 1;
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
         fhir:Coding.code [ fhir:value "SNO" ]       ];
       fhir:CodeableConcept.text [ fhir:value "Serial Number" ]     ];
     fhir:Identifier.value [ fhir:value "AMID-342135-8464" ]
  ];
  fhir:Device.status [ fhir:value "active"];
  fhir:Device.type [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:86184003;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "86184003" ];
       fhir:Coding.display [ fhir:value "Electrocardiographic monitor and recorder" ]     ];
     fhir:CodeableConcept.text [ fhir:value "ECG" ]
  ];
  fhir:Device.lotNumber [ fhir:value "43453424"];
  fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"];
  fhir:Device.model [ fhir:value "AB 45-J"];
  fhir:Device.contact [
     fhir:index 0;
     fhir:ContactPoint.system [ fhir:value "phone" ];
     fhir:ContactPoint.value [ fhir:value "ext 4352" ]
  ];
  fhir:Device.note [
     fhir:index 0;
     fhir:Annotation.authorReference [
       fhir:Reference.reference [ fhir:value "Practitioner/qicore-practitioner-example" ]     ];
     fhir:Annotation.time [ fhir:value "2015-06-28T14:03:32+10:00"^^xsd:dateTime ];
     fhir:Annotation.text [ fhir:value "QA Checked" ]
  ].

# - ontology header ------------------------------------------------------------

 a owl:Ontology;
  owl:imports fhir:fhir.ttl.