This page is part of the Quality Improvement Core Framework (v6.0.0: STU6 (v6.0.0)) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
: Device example - TTL Representation
Raw ttl | Download
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Device ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "example"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-device"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-device> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-qicore-device.html\">QICore Device</a></p></div><p><b>identifier</b>: <code>http://goodcare.org/devices/id</code>/345675, Serial Number/AMID-342135-8464</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>DeviceIdentifier</b></td><td><b>CarrierHRF</b></td></tr><tr><td style=\"display: none\">*</td><td>09504000059118</td><td>(01)09504000059118(17)141120(10)7654321D(21)10987654d321</td></tr></table><p><b>status</b>: active</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>lotNumber</b>: 43453424</p><p><b>modelNumber</b>: AB 45-J</p><p><b>type</b>: ECG <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#86184003 "Electrocardiographic monitor and recorder")</span></p><p><b>patient</b>: <a href=\"Patient-example.html\">Patient/example</a> " CHALMERS"</p><p><b>contact</b>: ph: ext 4352</p><p><b>note</b>: QA Checked (By Practitioner/example @Jun 28, 2015, 4:03:32 AM)</p></div>"
] ; #
fhir:identifier ( [
fhir:system [ fhir:v "http://goodcare.org/devices/id"^^xsd:anyURI ] ;
fhir:value [ fhir:v "345675" ]
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0203"^^xsd:anyURI ] ;
fhir:code [ fhir:v "SNO" ] ] ) ;
fhir:text [ fhir:v "Serial Number" ] ] ;
fhir:value [ fhir:v "AMID-342135-8464" ]
] ) ; #
fhir:udiCarrier ( [
fhir:deviceIdentifier [ fhir:v "09504000059118" ] ;
fhir:carrierHRF [ fhir:v "(01)09504000059118(17)141120(10)7654321D(21)10987654d321" ]
] ) ; #
fhir:status [ fhir:v "active"] ; #
fhir:manufacturer [ fhir:v "Acme Devices, Inc"] ; #
fhir:lotNumber [ fhir:v "43453424"] ; #
fhir:modelNumber [ fhir:v "AB 45-J"] ; #
fhir:type [
( fhir:coding [
a sct:86184003 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "86184003" ] ;
fhir:display [ fhir:v "Electrocardiographic monitor and recorder" ] ] ) ;
fhir:text [ fhir:v "ECG" ]
] ; #
fhir:patient [
fhir:reference [ fhir:v "Patient/example" ]
] ; #
fhir:contact ( [
fhir:system [ fhir:v "phone" ] ;
fhir:value [ fhir:v "ext 4352" ]
] ) ; #
fhir:note ( [
fhir:author [
a fhir:Reference ;
fhir:reference [ fhir:v "Practitioner/example" ] ] ;
fhir:time [ fhir:v "2015-06-28T14:03:32+10:00"^^xsd:dateTime ] ;
fhir:text [ fhir:v "QA Checked" ]
] ) . #