QI-Core Implementation Guide
7.0.0-ballot - STU7 Ballot United States of America flag

This page is part of the Quality Improvement Core Framework (v7.0.0-ballot: STU7 (v7.0.0) Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 6.0.0. For a full list of available versions, see the Directory of published versions

: Device example - XML Representation

Raw xml | Download



<Device xmlns="http://hl7.org/fhir">
  <id value="example"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-device"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Device example</b></p><a name="example"> </a><a name="hcexample"> </a><a name="example-en-US"> </a><p><b>identifier</b>: <code>http://goodcare.org/devices/id</code>/345675, Serial Number/AMID-342135-8464</p><h3>UdiCarriers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>DeviceIdentifier</b></td><td><b>CarrierHRF</b></td></tr><tr><td style="display: none">*</td><td>09504000059118</td><td>(01)09504000059118(17)141120(10)7654321D(21)10987654d321</td></tr></table><p><b>status</b>: Active</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>lotNumber</b>: 43453424</p><p><b>modelNumber</b>: AB 45-J</p><p><b>type</b>: <span title="Codes:{http://snomed.info/sct 86184003}">ECG</span></p><p><b>patient</b>: <a href="Patient-example.html">Jim Chalmers  Male, DoB: 1974-12-25 ( Medical record number (use: usual, period: 2001-05-06 --&gt; (ongoing)))</a></p><p><b>contact</b>: ph: ext 4352</p><p><b>note</b>: QA Checked (By Practitioner/example @2015-06-28 14:03:32+1000)</p></div>
  </text>
  <identifier>
    <system value="http://goodcare.org/devices/id"/>
    <value value="345675"/>
  </identifier>
  <identifier>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
        <code value="SNO"/>
      </coding>
      <text value="Serial Number"/>
    </type>
    <value value="AMID-342135-8464"/>
  </identifier>
  <udiCarrier>
    <deviceIdentifier value="09504000059118"/>
    <carrierHRF
                value="(01)09504000059118(17)141120(10)7654321D(21)10987654d321"/>
  </udiCarrier>
  <status value="active"/>
  <manufacturer value="Acme Devices, Inc"/>
  <lotNumber value="43453424"/>
  <modelNumber value="AB 45-J"/>
  <type>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="86184003"/>
      <display value="Electrocardiographic monitor and recorder"/>
    </coding>
    <text value="ECG"/>
  </type>
  <patient>🔗 
    <reference value="Patient/example"/>
  </patient>
  <contact>
    <system value="phone"/>
    <value value="ext 4352"/>
  </contact>
  <note>
    <authorReference>🔗 
      <reference value="Practitioner/example"/>
    </authorReference>
    <time value="2015-06-28T14:03:32+10:00"/>
    <text value="QA Checked"/>
  </note>
</Device>