ValueSet Comparison between http://hl7.org/fhir/us/core/ValueSet/us-core-vital-signs vs http://hl7.org/fhir/us/pacio-pfe/ValueSet/pfe-example-obs-vs

Messages

ErrorValueSet.urlValues for url differ: 'http://hl7.org/fhir/us/core/ValueSet/us-core-vital-signs' vs 'http://hl7.org/fhir/us/pacio-pfe/ValueSet/pfe-example-obs-vs'
ErrorValueSet.versionValues for version differ: '5.0.1' vs '1.0.0'
InformationValueSet.nameValues for name differ: 'UsCoreVitalSigns' vs 'PFEExampleObservationsVS'
InformationValueSet.titleValues for title differ: 'US Core Vital Signs ValueSet' vs 'Personal Functioning and Engagement Example Observations Value Set'
InformationValueSet.statusValues for status differ: 'active' vs 'draft'
InformationValueSet.dateValues for date differ: '2020-11-17' vs '2024-01-05T16:57:50+00:00'
InformationValueSet.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International / Patient Care'
InformationValueSet.copyrightValues for copyright differ: 'This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc' vs 'This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc.'
ErrorValueSet.compose.exclude[0]Code 59576-9 removed
ErrorValueSet.compose.exclude[0]Code 8289-1 removed
ErrorValueSet.compose.exclude[0]Code 77606-2 removed
ErrorValueSet.compose.exclude[0]Code 59408-5 removed
ErrorValueSet.compose.exclude[0]Code 3150-0 removed
ErrorValueSet.compose.exclude[0]Code 3151-8 removed
ErrorValueSet.compose.exclude[0]Code 101265-7 added
ErrorValueSet.compose.exclude[0]Code 95019-6 added
ErrorValueSet.compose.exclude[0]Code 79532-8 added
ErrorValueSet.compose.exclude[0]Code 99828-6 added
ErrorValueSet.compose.exclude[0]Code 99831-0 added
ErrorValueSet.compose.exclude[0]Code 99835-1 added
ErrorValueSet.compose.exclude[0]Code 91375-6 added

Metadata

NameValueComments
.compose.inactive
    .compose.lockedDate
      .copyrightThis material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, IncThis material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc.
      • Values Differ
      .date2020-11-172024-01-05T16:57:50+00:00
      • Values Differ
      .descriptionThe vital sign codes from the base FHIR and US Core Vital Signs.This value set includes LOINC codes that provide examples of observations within the scope of the Personal Functioning and Engagement IG.
      • Values Differ
      .experimentalfalse
        .immutable
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .nameUsCoreVitalSignsPFEExampleObservationsVS
              • Values Differ
              .publisherHL7 International - Cross-Group ProjectsHL7 International / Patient Care
              • Values Differ
              .purpose
                .statusactivedraft
                • Values Differ
                .titleUS Core Vital Signs ValueSetPersonal Functioning and Engagement Example Observations Value Set
                • Values Differ
                .urlhttp://hl7.org/fhir/us/core/ValueSet/us-core-vital-signshttp://hl7.org/fhir/us/pacio-pfe/ValueSet/pfe-example-obs-vs
                • Values Differ
                .version5.0.11.0.0
                • Values Differ

                Definition

                ItemPropertyValueComments
                .includehttp://loinc.org
                  ..Concept59576-9
                  • Removed this Concept
                  ..Concept8289-1
                  • Removed this Concept
                  ..Concept77606-2
                  • Removed this Concept
                  ..Concept3150-0
                  • Removed this Concept
                  ..Concept3151-8
                  • Removed this Concept
                  ..Concept101265-7Version: MDS v3.0 - RAI v1.18.11 - Functional Abilities and Goals - Admission [CMS Assessment]
                  • Added this Concept
                  ..Concept95019-6Version: Eating - usual functional ability during assessment period [CMS Assessment]
                  • Added this Concept
                  ..Concept79532-8Version: Daily activity score [AM-PAC]
                  • Added this Concept
                  ..Concept99828-6Version: Functional Communication Measure - Multi-Modal Functional Communication panel [ASHA NOMS]
                  • Added this Concept
                  ..Concept99831-0Version: Frequency of conveying meaningful complex messages in low demand situations
                  • Added this Concept
                  ..Concept99835-1Version: Functional Communication Measure - Multi-Modal Functional Communication score [ASHA NOMS]
                  • Added this Concept
                  ..Concept91375-6Version: Hearing threshold Ear - left --250 Hz
                  • Added this Concept
                  .include
                  • Removed Include

                  Expansion

                  Unable to generate expansion - see errors