PACIO Personal Functioning and Engagement Implementation Guide
2.0.0-ballot - STU2 Ballot United States of America flag

This page is part of the PACIO Personal Functioning and Engagement Implementation Guide (v2.0.0-ballot: STU 2 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

: ServiceRequest-code - JSON Representation

Active as of 2024-09-01

Raw json | Download


{
  "resourceType" : "SearchParameter",
  "id" : "ServiceRequest-code",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: SearchParameter ServiceRequest-code</b></p><a name=\"ServiceRequest-code\"> </a><a name=\"hcServiceRequest-code\"> </a><a name=\"ServiceRequest-code-en-US\"> </a><h2>ServiceRequestCodeSearchParameter</h2><p>Parameter <code>name</code>:<code>string</code></p><div><p>Select ServiceRequests with the specified code</p>\n</div><table class=\"grid\"><tr><td>Resource</td><td><a href=\"http://hl7.org/fhir/R4/servicerequest.html\">ServiceRequest</a></td></tr><tr><td>Expression</td><td><code>ServiceRequest.code</code></td></tr><tr><td>Processing Mode</td><td>Normal</td></tr><tr><td>Multiples</td><td><ul><li>multipleAnd: The parameter may repeat in order to specify multiple values that must all be true</li><li>multipleOr: The parameter may have multiple values (separated by comma) where at least one must be true</li></ul></td></tr><tr><td>Modifiers</td><td>Allowed: exact, contains</td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "pc"
    }
  ],
  "url" : "http://hl7.org/fhir/us/pacio-pfe/SearchParameter/ServiceRequest-code",
  "version" : "2.0.0-ballot",
  "name" : "ServiceRequestCodeSearchParameter",
  "status" : "active",
  "date" : "2024-09-01T18:06:11+00:00",
  "publisher" : "HL7 International / Patient Care",
  "contact" : [
    {
      "name" : "HL7 International / Patient Care",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/patientcare"
        },
        {
          "system" : "email",
          "value" : "patientcare@lists.HL7.org"
        }
      ]
    },
    {
      "name" : "PACIO project",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/patientcare"
        },
        {
          "system" : "email",
          "value" : "info@pacioproject.org"
        }
      ]
    }
  ],
  "description" : "Select ServiceRequests with the specified code",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "US"
        }
      ]
    }
  ],
  "code" : "name",
  "base" : [
    "ServiceRequest"
  ],
  "type" : "string",
  "expression" : "ServiceRequest.code",
  "xpathUsage" : "normal",
  "multipleOr" : true,
  "multipleAnd" : true,
  "modifier" : [
    "exact",
    "contains"
  ]
}