Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab vs http://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fs

Left:US Core Laboratory Result Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab)
Right:PACIO Functional Status (http://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fs)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fs'
ErrorStructureDefinition.versionValues for version differ: '4.0.0' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreLaboratoryResultObservationProfile' vs 'FunctionalStatus'
InformationStructureDefinition.titleValues for title differ: 'US Core Laboratory Result Observation Profile' vs 'PACIO Functional Status'
InformationStructureDefinition.dateValues for date differ: '2020-06-27' vs '2021-11-03T21:36:25+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 Patient Care Work Group'
WarningObservationElements differ in definition: 'This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements.' 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservation.extensionElements differ in short: 'Additional content defined by implementations' 'Extension'
WarningObservation.extensionElements differ in definition: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' 'An Extension'
WarningObservation.basedOnElements differ in short: 'Fulfills plan, proposal or order' 'Currently not used in FunctionalStatus.'
WarningObservation.partOfElements differ in short: 'Part of referenced event' 'Currently not used in FunctionalStatus.'
WarningObservation.statusElements differ in short: 'registered | preliminary | final | amended +' 'Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.categoryElements differ in short: 'Classification of type of observation' 'A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Laboratory Test Name' 'For a Post-Acute Care Assessment, code should be a LOINC code and text for the question or concept name.'
WarningObservation.codeElements differ in definition: 'The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
ErrorObservation.codeElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.subjectElements differ in short: 'Who and/or what the observation is about' 'Subject should only be Patient for functional status'
ErrorObservation.subjectElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.focusElements differ in short: 'What the observation is about, when it is not about the subject of record' 'Currently not used in FunctionalStatus.'
WarningObservation.effective[x]Elements differ in definition: 'For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked.' 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
ErrorObservation.effective[x]Elements differ in definition for mustSupport: 'true' 'false'
WarningObservation.issuedElements differ in short: 'Date/Time this version was made available' 'Currently not used in FunctionalStatus.'
WarningObservation.performerElements differ in short: 'Who is responsible for the observation' 'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.'
WarningObservation.value[x]Elements differ in short: 'Result Value' 'Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension.'
WarningObservation.value[x]Elements differ in definition: 'The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT] if the concept exists. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification.' 'The information determined as a result of making the observation, if the information has a simple value.'
ErrorObservation.value[x]Elements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.interpretationElements differ in short: 'High, low, normal, etc.' 'Currently not used in FunctionalStatus.'
WarningObservation.bodySiteElements differ in short: 'Observed body part' 'Currently not used in FunctionalStatus.'
WarningObservation.methodElements differ in short: 'How it was done' 'Currently not used in FunctionalStatus.'
WarningObservation.specimenElements differ in short: 'Specimen used for this observation' 'Currently not used in FunctionalStatus.'
WarningObservation.deviceElements differ in short: '(Measurement) Device' 'Currently not used in FunctionalStatus.'
WarningObservation.referenceRangeElements differ in short: 'Provides guide for interpretation' 'Currently not used in FunctionalStatus.'
WarningObservation.hasMemberElements differ in short: 'Related resource that belongs to the Observation group' 'Currently not used in FunctionalStatus.'
WarningObservation.derivedFromElements differ in short: 'Related measurements the observation is made from' 'Should point back to the SDC QuestionnaireResponse that this resource is derived from.'
ErrorObservation.derivedFromElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.derivedFromType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]])
WarningObservation.componentElements differ in short: 'Component results' 'Currently not used in FunctionalStatus.'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observation
      .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
      • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
      .date2020-06-272021-11-03T21:36:25+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve laboratory test resultsAn exchange of functional status observation for a patient. This profile is used for exchanging a single observation data generally included in a set of observation data collected through the use of a structured resource (e.g. assessment tool, instrument, or screen).
      • Values Differ
      .experimentalfalse
      • Removed the item 'false'
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
            .kindresource
              .nameUSCoreLaboratoryResultObservationProfileFunctionalStatus
              • Values Differ
              .publisherHL7 International - US Realm Steering CommitteeHL7 Patient Care Work Group
              • Values Differ
              .purpose
                .statusactive
                  .titleUS Core Laboratory Result Observation ProfilePACIO Functional Status
                  • Values Differ
                  .typeObservation
                    .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-labhttp://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fs
                    • Values Differ
                    .version4.0.01.0.0
                    • Values Differ

                    Structure

                    NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                    .. Observation II
                    • Elements differ in definition: "This profile is created to meet the 2015 Edition Common Clinical Data Set 'Laboratory test(s) and Laboratory value(s)/result(s)' requirements." "Measurements and simple assertions made about a patient, device or other subject."
                    ... id ΣΣ
                      ... meta ΣΣ
                        ... implicitRules ?!Σ?!Σ
                          ... language
                            ... text
                              ... contained
                                ... extension ExtensionExtension
                                • Elements differ in short: "Additional content defined by implementations" "Extension"
                                • Elements differ in definition: "May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension." "An Extension"
                                ... modifierExtension ?!?!
                                  ... identifier ΣΣ
                                    ... basedOn ΣΣ
                                    • Elements differ in short: "Fulfills plan, proposal or order" "Currently not used in FunctionalStatus."
                                    ... partOf ΣΣ
                                    • Elements differ in short: "Part of referenced event" "Currently not used in FunctionalStatus."
                                    ... status ?!SΣ?!Σ
                                    • Elements differ in short: "registered | preliminary | final | amended +" "Should have the value 'final' when the observation is complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used."
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    ... Slices for category S
                                    • Elements differ in short: "Classification of type of observation" "A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code."
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    ... code SΣΣ
                                    • Elements differ in short: "Laboratory Test Name" "For a Post-Acute Care Assessment, code should be a LOINC code and text for the question or concept name."
                                    • Elements differ in definition: "The test that was performed. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."
                                    • Elements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    ... subject SΣΣ
                                    • Elements differ in short: "Who and/or what the observation is about" "Subject should only be Patient for functional status"
                                    • Elements differ in definition for mustSupport: "true" "false"
                                    ... focus ΣΣ
                                    • Elements differ in short: "What the observation is about, when it is not about the subject of record" "Currently not used in FunctionalStatus."
                                    ... encounter ΣΣ
                                      ... effective[x] SΣIΣ
                                      • Elements differ in definition: "For lab tests this is the specimen collection date. For Ask at Order Entry Questions (AOE)'s this is the date the question was asked." "The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself."
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... issued ΣΣ
                                      • Elements differ in short: "Date/Time this version was made available" "Currently not used in FunctionalStatus."
                                      ... performer ΣΣ
                                      • Elements differ in short: "Who is responsible for the observation" "The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization."
                                      ... value[x] SΣIΣI
                                      • Elements differ in short: "Result Value" "Whenever possible should use the CodeableConcept datatype to provide a suitable code to define the concept for the observation data. As for values like an assessment score or roll-up value, the datatype for this element should be determined by Observation.code. However, for values that are ordinal, may use the CodeableConcept datatype along with the Ordinal Value Extension."
                                      • Elements differ in definition: "The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT] if the concept exists. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM]. A FHIR [UCUM Codes value set] that defines all UCUM codes is in the FHIR specification." "The information determined as a result of making the observation, if the information has a simple value."
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... dataAbsentReason SII
                                      • Elements differ in definition for mustSupport: "true" "false"
                                      ... interpretation
                                      • Elements differ in short: "High, low, normal, etc." "Currently not used in FunctionalStatus."
                                      ... note
                                        ... bodySite
                                        • Elements differ in short: "Observed body part" "Currently not used in FunctionalStatus."
                                        ... method
                                        • Elements differ in short: "How it was done" "Currently not used in FunctionalStatus."
                                        ... specimen
                                        • Elements differ in short: "Specimen used for this observation" "Currently not used in FunctionalStatus."
                                        ... device
                                        • Elements differ in short: "(Measurement) Device" "Currently not used in FunctionalStatus."
                                        ... referenceRange II
                                        • Elements differ in short: "Provides guide for interpretation" "Currently not used in FunctionalStatus."
                                        .... id
                                          .... extension ExtensionExtension
                                            .... modifierExtension ?!Σ?!Σ
                                              .... low II
                                                .... high II
                                                  .... type
                                                    .... appliesTo
                                                      .... age
                                                        .... text
                                                          ... hasMember ΣΣ
                                                          • Elements differ in short: "Related resource that belongs to the Observation group" "Currently not used in FunctionalStatus."
                                                          ... derivedFrom ΣSΣ
                                                          • Elements differ in short: "Related measurements the observation is made from" "Should point back to the SDC QuestionnaireResponse that this resource is derived from."
                                                          • Elements differ in definition for mustSupport: "false" "true"
                                                          • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]])
                                                          ... component ΣΣ
                                                          • Elements differ in short: "Component results" "Currently not used in FunctionalStatus."
                                                          .... id
                                                            .... extension ExtensionExtension
                                                              .... modifierExtension ?!Σ?!Σ
                                                                .... code ΣΣ
                                                                  .... value[x] ΣΣ
                                                                    .... dataAbsentReason II
                                                                      .... interpretation
                                                                        .... referenceRange

                                                                          doco Documentation for this format