Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaging vs http://hl7.org/fhir/us/pacio-adi/StructureDefinition/PADI-DocumentationObservation

Left:US Core Imaging Result Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaging)
Right:ADI Documentation Observation (http://hl7.org/fhir/us/pacio-adi/StructureDefinition/PADI-DocumentationObservation)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaging' vs 'http://hl7.org/fhir/us/pacio-adi/StructureDefinition/PADI-DocumentationObservation'
ErrorStructureDefinition.versionValues for version differ: '4.1.0' vs '0.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreImagingResultObservationProfile' vs 'PADIDocumentationObservation'
InformationStructureDefinition.titleValues for title differ: 'US Core Imaging Result Observation Profile' vs 'ADI Documentation Observation'
InformationStructureDefinition.dateValues for date differ: '2021-11-09' vs '2021-12-06T20:50:55+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 Patient Empowerment Working Group'
ErrorObservation.textElements differ in definition for mustSupport: 'false' 'true'
ErrorObservation.statusElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.categoryElements differ in definition for mustSupport: 'true' 'false'
WarningObservation.codeElements differ in short: 'Imaging Name' 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'The name of the imaging test performed on a patient. A LOINC **SHALL** be used if the concept is present in LOINC.' 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.focusElements differ in short: 'What the observation is about, when it is not about the subject of record' 'Reference to the additional document this observation is about'
WarningObservation.value[x]Elements differ in short: 'Result Value' 'Actual result'
ErrorObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' 'false'
ErrorObservation.noteElements differ in definition for mustSupport: 'false' 'true'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observation
      .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
      • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
      .date2021-11-092021-12-06T20:50:55+00:00
      • Values Differ
      .descriptionDefines constraints and extensions on the Observation resource for the minimal set of data to query and retrieve structured and unstructured (narrative) components of imaging test results. These observations include reasons, findings, and impressions.This profile is used to indicate if additional advance directive documents, such as physician order for life sustaining treatment (MOLST or POLST) or Do Not Resuscitate Order (DNR) exist and a reference to the document.
      • Values Differ
      .experimental
        .fhirVersion4.0.1
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
              .kindresource
                .nameUSCoreImagingResultObservationProfilePADIDocumentationObservation
                • Values Differ
                .publisherHL7 International - Cross-Group ProjectsHL7 Patient Empowerment Working Group
                • Values Differ
                .purpose
                  .statusactive
                    .titleUS Core Imaging Result Observation ProfileADI Documentation Observation
                    • Values Differ
                    .typeObservation
                      .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-imaginghttp://hl7.org/fhir/us/pacio-adi/StructureDefinition/PADI-DocumentationObservation
                      • Values Differ
                      .version4.1.00.1.0
                      • Values Differ

                      Structure

                      NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                      .. Observation II
                        ... id ΣΣ
                          ... meta ΣΣ
                            ... implicitRules ?!Σ?!Σ
                              ... language
                                ... text S
                                • Elements differ in definition for mustSupport: "false" "true"
                                ... contained
                                  ... extension ExtensionExtension
                                    ... modifierExtension ?!?!
                                      ... identifier ΣΣ
                                        ... basedOn ΣΣ
                                          ... partOf ΣΣ
                                            ... status ?!SΣ?!Σ
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... Slices for category S
                                            • Elements differ in definition for mustSupport: "true" "false"
                                            ... code SΣSΣ
                                            • Elements differ in short: "Imaging Name" "Type of observation (code / type)"
                                            • Elements differ in definition: "The name of the imaging test performed on a patient. A LOINC **SHALL** be used if the concept is present in LOINC." "Describes what was observed. Sometimes this is called the observation "name"."
                                            • Elements differ in comments: "The typical patterns for codes are: 1) a LOINC code either as a translation from a "local" code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display." "*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation."
                                            ... subject SΣSΣ
                                              ... focus ΣΣ
                                              • Elements differ in short: "What the observation is about, when it is not about the subject of record" "Reference to the additional document this observation is about"
                                              ... encounter ΣΣ
                                                ... effective[x] SΣISΣ
                                                  ... issued ΣΣ
                                                    ... performer ΣΣ
                                                      ... value[x] SΣISΣI
                                                      • Elements differ in short: "Result Value" "Actual result"
                                                      ... dataAbsentReason SII
                                                      • Elements differ in definition for mustSupport: "true" "false"
                                                      ... interpretation
                                                        ... note S
                                                        • Elements differ in definition for mustSupport: "false" "true"
                                                        ... bodySite
                                                          ... method
                                                            ... specimen
                                                              ... device
                                                                ... referenceRange II
                                                                  .... id
                                                                    .... extension ExtensionExtension
                                                                      .... modifierExtension ?!Σ?!Σ
                                                                        .... low II
                                                                          .... high II
                                                                            .... type
                                                                              .... appliesTo
                                                                                .... age
                                                                                  .... text
                                                                                    ... hasMember ΣΣ
                                                                                      ... derivedFrom ΣΣ
                                                                                        ... component ΣΣ
                                                                                          .... id
                                                                                            .... extension ExtensionExtension
                                                                                              .... modifierExtension ?!Σ?!Σ
                                                                                                .... code ΣΣ
                                                                                                  .... value[x] ΣΣ
                                                                                                    .... dataAbsentReason II
                                                                                                      .... interpretation
                                                                                                        .... referenceRange

                                                                                                          doco Documentation for this format