Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height' vs 'http://hl7.org/fhir/us/odh/StructureDefinition/odh-CombatZonePeriod' |
Error | StructureDefinition.version | Values for version differ: '4.0.0' vs '1.1.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreBodyHeightProfile' vs 'CombatZonePeriod' |
Information | StructureDefinition.title | Values for title differ: 'US Core Body Height Profile' vs 'Combat Zone Period' |
Information | StructureDefinition.date | Values for date differ: '2020-11-17' vs '2020-01-04' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 International Public Health Work Group' |
Information | StructureDefinition.copyright | Values for copyright differ: 'Used by permission of HL7 International, all rights reserved Creative Commons License' vs '©2020+ HL7 International Public Health Work Group. Package hl7.fhir.us.odh#1.0.0 based on FHIR 4.0.1. Generated 2020-01-08.
Links: Home | QA Report | Search | Version History external | CC0 external | Propose a change external' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'US Core Body Height Profile'
'Combat Zone Period' |
Warning | Observation | Elements differ in definition:
'Defines constraints on Observation to represent body height observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
'Self-reported date range(s) when a person worked in what is considered a combat zone; sometimes called a hazardous duty work. Both civilian workers, such as Department of Defense contractors, and military service members could have worked in combat zones. Multiple periods in combat zone should be recorded using multiple instances of this profile.' |
Warning | Observation.basedOn | Elements differ in short:
'Fulfills plan, proposal or order'
'The plan, proposal or order that is fulfilled in whole or in part by this observation' |
Warning | Observation.basedOn | Elements differ in definition:
'A plan, proposal or order that is fulfilled in whole or in part by this event. For example, a MedicationRequest may require a patient to have laboratory test performed before it is dispensed.'
'The plan, proposal or order that is fulfilled in whole or in part by this observation.' |
Error | Observation.basedOn | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan], CanonicalType[http://hl7.org/fhir/StructureDefinition/DeviceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/NutritionOrder], CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) |
Warning | Observation.partOf | Elements differ in short:
'Part of referenced event'
'The larger procedure that this particular observation is a component or step' |
Warning | Observation.partOf | Elements differ in definition:
'A larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure.'
'The larger procedure that this particular observation is a component or step.' |
Error | Observation.partOf | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationAdministration], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationDispense], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationStatement], CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure], CanonicalType[http://hl7.org/fhir/StructureDefinition/Immunization], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure]]) |
Error | Observation.status | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Body Height'
'Type of observation (code / type)' |
Warning | Observation.code | Elements differ in definition:
'Coded Responses from C-CDA Vital Sign Results.'
'Describes what was observed. Sometimes this is called the observation 'name'.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Error | Observation.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.subject | Elements differ in short:
'Who and/or what the observation is about'
'The subject of an observation' |
Warning | Observation.subject | Elements differ in definition:
'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.'
'The subject of an observation.' |
Error | Observation.subject | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinically relevant time/time-period for observation' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Error | Observation.effective[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.effective[x] | Cardinality Mismatch: 1..1/0..0 |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs Value'
'Actual result' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Related resource that belongs to the Observation group' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Warning | Observation.component | Elements differ in short:
'Component observations'
'Component results' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting component observation such as systolic and diastolic blood pressure.'
'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' |
Error | Observation.component | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Component Value'
'Actual component result' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.referenceRange | Type Mismatch:
BackboneElement |