This page is part of the Occupational Data for Health (ODH) FHIR IG (v0.1.0: STU 1 Ballot 1) based on FHIR R3. The current version which supercedes this version is 1.2.0. For a full list of available versions, see the Directory of published versions
{ "resourceType" : "StructureDefinition", "id" : "cimi-entity-Device-model", "text" : { "status" : "generated", "div" : "<div xmlns="http://www.w3.org/1999/xhtml"> <p><b>ODH Device Logical Model</b></p> <p>A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients.</p> </div>" }, "url" : "http://hl7.org/fhir/us/odh/StructureDefinition/cimi-entity-Device-model", "identifier" : [ { "system" : "http://hl7.org/fhir/us/odh", "value" : "cimi.entity.Device" } ], "version" : "0.1.0", "name" : "DeviceModel", "title" : "ODH Device Logical Model", "status" : "draft", "date" : "2018-08-17T00:00:00+10:00", "publisher" : "HL7", "contact" : [ { "telecom" : [ { "system" : "url", "value" : "http://standardhealthrecord.org" } ] } ], "description" : "A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients.", "kind" : "logical", "abstract" : false, "type" : "cimi-entity-Device-model", "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Element", "derivation" : "specialization", "snapshot" : { "element" : [ { "id" : "cimi-entity-Device-model", "path" : "cimi-entity-Device-model", "definition" : "A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients.", "min" : 0, "max" : "*", "base" : { "path" : "cimi-entity-Device-model", "min" : 0, "max" : "*" }, "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.type", "path" : "cimi-entity-Device-model.type", "code" : [ { "system" : "http://ncimeta.nci.nih.gov", "code" : "C0332307" } ], "short" : "The most specific code (lowest level term) describing the kind or sort of thing being represented.", "definition" : "The most specific code (lowest level term) describing the kind or sort of thing being represented.", "min" : 1, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.type", "min" : 1, "max" : "1" }, "type" : [ { "code" : "Coding" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false, "binding" : { "strength" : "required", "valueSetReference" : { "reference" : "http://hl7.org/fhir/us/odh/ValueSet/cimi-entity-DeviceVS" } } }, { "id" : "cimi-entity-Device-model.deviceUdi", "path" : "cimi-entity-Device-model.deviceUdi", "short" : "Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device.", "definition" : "Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device.", "min" : 0, "max" : "*", "base" : { "path" : "cimi-entity-Device-model.deviceUdi", "min" : 0, "max" : "*" }, "type" : [ { "code" : "string" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.vendorModelNumber", "path" : "cimi-entity-Device-model.vendorModelNumber", "short" : "The model number of the device, assigned by the manufacturer or vendor.", "definition" : "The model number of the device, assigned by the manufacturer or vendor.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.vendorModelNumber", "min" : 0, "max" : "1" }, "type" : [ { "code" : "string" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.manufacturerName", "path" : "cimi-entity-Device-model.manufacturerName", "short" : "The name of the company who produce the device.", "definition" : "The name of the company who produce the device.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.manufacturerName", "min" : 0, "max" : "1" }, "type" : [ { "code" : "string" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.manufactureDate", "path" : "cimi-entity-Device-model.manufactureDate", "short" : "When the item (medication, device, etc.) was produced.", "definition" : "When the item (medication, device, etc.) was produced.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.manufactureDate", "min" : 0, "max" : "1" }, "type" : [ { "code" : "dateTime" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.expirationDate", "path" : "cimi-entity-Device-model.expirationDate", "short" : "When the item (medication, device, etc.) will expire.", "definition" : "When the item (medication, device, etc.) will expire.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.expirationDate", "min" : 0, "max" : "1" }, "type" : [ { "code" : "dateTime" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.version", "path" : "cimi-entity-Device-model.version", "code" : [ { "system" : "http://ncimeta.nci.nih.gov", "code" : "C0333052" } ], "short" : "A number or code associated with the product that identifies a particular release iteration.", "definition" : "A number or code associated with the product that identifies a particular release iteration.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.version", "min" : 0, "max" : "1" }, "type" : [ { "code" : "string" }, { "code" : "id" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.url", "path" : "cimi-entity-Device-model.url", "short" : "A unique URL on which the device may be contacted directly.", "definition" : "A unique URL on which the device may be contacted directly.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.url", "min" : 0, "max" : "1" }, "type" : [ { "code" : "uri" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false } ] }, "differential" : { "element" : [ { "id" : "cimi-entity-Device-model", "path" : "cimi-entity-Device-model", "definition" : "A specific durable physical device used in diagnosis or treatment. The value is the coding for a type of device, for example, a CPAP machine. The same device might be used on multiple patients.", "min" : 0, "max" : "*", "base" : { "path" : "cimi-entity-Device-model", "min" : 0, "max" : "*" }, "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.type", "path" : "cimi-entity-Device-model.type", "code" : [ { "system" : "http://ncimeta.nci.nih.gov", "code" : "C0332307" } ], "short" : "The most specific code (lowest level term) describing the kind or sort of thing being represented.", "definition" : "The most specific code (lowest level term) describing the kind or sort of thing being represented.", "min" : 1, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.type", "min" : 1, "max" : "1" }, "type" : [ { "code" : "Coding" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false, "binding" : { "strength" : "required", "valueSetReference" : { "reference" : "http://hl7.org/fhir/us/odh/ValueSet/cimi-entity-DeviceVS" } } }, { "id" : "cimi-entity-Device-model.deviceUdi", "path" : "cimi-entity-Device-model.deviceUdi", "short" : "Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device.", "definition" : "Unique Device Identifier (UDI) Barcode string number for a device, assigned by the organization using the device.", "min" : 0, "max" : "*", "base" : { "path" : "cimi-entity-Device-model.deviceUdi", "min" : 0, "max" : "*" }, "type" : [ { "code" : "string" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.vendorModelNumber", "path" : "cimi-entity-Device-model.vendorModelNumber", "short" : "The model number of the device, assigned by the manufacturer or vendor.", "definition" : "The model number of the device, assigned by the manufacturer or vendor.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.vendorModelNumber", "min" : 0, "max" : "1" }, "type" : [ { "code" : "string" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.manufacturerName", "path" : "cimi-entity-Device-model.manufacturerName", "short" : "The name of the company who produce the device.", "definition" : "The name of the company who produce the device.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.manufacturerName", "min" : 0, "max" : "1" }, "type" : [ { "code" : "string" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.manufactureDate", "path" : "cimi-entity-Device-model.manufactureDate", "short" : "When the item (medication, device, etc.) was produced.", "definition" : "When the item (medication, device, etc.) was produced.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.manufactureDate", "min" : 0, "max" : "1" }, "type" : [ { "code" : "dateTime" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.expirationDate", "path" : "cimi-entity-Device-model.expirationDate", "short" : "When the item (medication, device, etc.) will expire.", "definition" : "When the item (medication, device, etc.) will expire.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.expirationDate", "min" : 0, "max" : "1" }, "type" : [ { "code" : "dateTime" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.version", "path" : "cimi-entity-Device-model.version", "code" : [ { "system" : "http://ncimeta.nci.nih.gov", "code" : "C0333052" } ], "short" : "A number or code associated with the product that identifies a particular release iteration.", "definition" : "A number or code associated with the product that identifies a particular release iteration.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.version", "min" : 0, "max" : "1" }, "type" : [ { "code" : "string" }, { "code" : "id" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false }, { "id" : "cimi-entity-Device-model.url", "path" : "cimi-entity-Device-model.url", "short" : "A unique URL on which the device may be contacted directly.", "definition" : "A unique URL on which the device may be contacted directly.", "min" : 0, "max" : "1", "base" : { "path" : "cimi-entity-Device-model.url", "min" : 0, "max" : "1" }, "type" : [ { "code" : "uri" } ], "mustSupport" : false, "isModifier" : false, "isSummary" : false } ] } }