Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/military-service/StructureDefinition/military-service-Occupation

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:Military Occupation (http://hl7.org/fhir/us/military-service/StructureDefinition/military-service-Occupation)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/military-service/StructureDefinition/military-service-Occupation'
ErrorStructureDefinition.versionValues for version differ: '6.1.0-snapshot1' vs '1.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'MilitaryOccupation'
InformationStructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'Military Occupation'
InformationStructureDefinition.dateValues for date differ: '2022-04-20' vs '2023-05-30T15:01:17+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'Cross Group Projects WG'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Pulse Oximetry Profile' vs 'Measurements and simple assertions'
WarningObservationElements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservationElements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
InformationObservation.idElement minimum cardinalities differ: '0' vs '1'
InformationObservation.basedOnElement maximum cardinalities differ: '2147483647' vs '0'
InformationObservation.partOfElement maximum cardinalities differ: '2147483647' vs '0'
WarningObservation.statusElements differ in short: '(USCDI) registered | preliminary | final | amended +' vs 'registered | preliminary | final | amended +'
WarningObservation.categoryElements differ in short: '(USCDI) Classification of type of observation' vs 'Classification of type of observation'
InformationObservation.categoryElement minimum cardinalities differ: '1' vs '0'
WarningObservation.codeElements differ in short: '(USCDI) Oxygen Saturation by Pulse Oximetry' vs 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood).' vs '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.code.codingElements differ in short: '(USCDI) Code defined by a terminology system' vs 'Code defined by a terminology system'
WarningObservation.code.codingElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.code.codingElement minimum cardinalities differ: '2' vs '0'
WarningObservation.subjectElements differ in short: '(USCDI) Who and/or what the observation is about' vs 'Who and/or what the observation is about'
InformationObservation.focusElement maximum cardinalities differ: '2147483647' vs '0'
InformationObservation.encounterElement maximum cardinalities differ: '1' vs '0'
WarningObservation.effective[x]Elements differ in short: '(USCDI) Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
WarningObservation.effective[x]Elements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.issuedElement maximum cardinalities differ: '1' vs '0'
InformationObservation.performerElement maximum cardinalities differ: '2147483647' vs '0'
WarningObservation.value[x]Elements differ in short: '(USCDI) Vital Signs Value' vs 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.value[x]Element minimum cardinalities differ: '0' vs '1'
WarningObservation.dataAbsentReasonElements differ in short: '(USCDI) Why the result is missing' vs 'Why the result is missing'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.dataAbsentReasonElement maximum cardinalities differ: '1' vs '0'
InformationObservation.interpretationElement maximum cardinalities differ: '2147483647' vs '0'
InformationObservation.noteElement maximum cardinalities differ: '2147483647' vs '1'
InformationObservation.bodySiteElement maximum cardinalities differ: '1' vs '0'
InformationObservation.methodElement maximum cardinalities differ: '1' vs '0'
InformationObservation.specimenElement maximum cardinalities differ: '1' vs '0'
InformationObservation.deviceElement maximum cardinalities differ: '1' vs '0'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' vs 'Related resource that belongs to the Observation group'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
InformationObservation.derivedFromElement maximum cardinalities differ: '2147483647' vs '0'
WarningObservation.componentElements differ in short: '(USCDI) Used when reporting flow rates or oxygen concentration.' vs 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting flow rates or oxygen concentration.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
WarningObservation.component.codeElements differ in short: '(USCDI) Type of component observation (code / type)' vs 'Type of component observation (code / type)'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: '(USCDI) Vital Sign Component Value' vs 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in short: '(USCDI) Why the component result is missing' vs 'Why the component result is missing'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2022-04-202023-05-30T15:01:17+00:00
    • Values Differ
    .descriptionTo promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch pulse oximetry and inspired oxygen observations with a standard LOINC codes and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies which *additional* core elements, extensions, vocabularies, and value sets **SHALL** be present and constrains the way the elements are used when using the profile. It provides the floor for standards development for specific use cases.The profile reuses the ODH PastOrPresentJob profile to apply it specifically to military jobs/occupations. The observation resource that conforms to this specification is referenced by Military Service Episode.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCorePulseOximetryProfileMilitaryOccupation
            • Values Differ
            .publisherHL7 International - Cross-Group ProjectsCross Group Projects WG
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Pulse Oximetry ProfileMilitary Occupation
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/military-service/StructureDefinition/military-service-Occupation
                  • Values Differ
                  .version6.1.0-snapshot11.0.0
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation C0..*USCoreVitalSignsProfileUS Core Pulse Oximetry Profile
                  C0..*ObservationMeasurements and simple assertions
                  • Elements differ in short: 'US Core Pulse Oximetry Profile' vs 'Measurements and simple assertions'
                  • Elements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
                  • Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
                  ... id Σ0..1idLogical id of this artifactΣ1..1idLogical id of this artifact
                  • Element minimum cardinalities differ: '0' vs '1'
                  ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                    ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                      ... language 0..1codeLanguage of the resource content
                      Binding: ?? (preferred): A human language.

                      Additional BindingsPurpose
                      ??Max Binding
                      0..1codeLanguage of the resource content
                      Binding: ?? (preferred): A human language.

                      Additional BindingsPurpose
                      ??Max Binding
                        ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                          ... contained 0..*ResourceContained, inline Resources
                          0..*ResourceContained, inline Resources
                            ... extension 0..*ExtensionAdditional content defined by implementations
                            0..*ExtensionAdditional content defined by implementations
                              ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                              ?!0..*ExtensionExtensions that cannot be ignored
                                ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                Σ0..*IdentifierBusiness Identifier for observation
                                  ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                  Σ0..0
                                  • Element maximum cardinalities differ: '2147483647' vs '0'
                                  ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                  Σ0..0
                                  • Element maximum cardinalities differ: '2147483647' vs '0'
                                  ... status ?!SΣ1..1code(USCDI) registered | preliminary | final | amended +
                                  Binding: ?? (required)
                                  ?!SΣ1..1coderegistered | preliminary | final | amended +
                                  Binding: ?? (required): Codes providing the status of an observation.

                                  • Elements differ in short: '(USCDI) registered | preliminary | final | amended +' vs 'registered | preliminary | final | amended +'
                                  ... Slices for category S1..*CodeableConcept(USCDI) Classification of type of observation
                                  Slice: Unordered, Open by value:coding.code, value:coding.system
                                  Binding: ?? (preferred): Codes for high level observation categories.


                                  S0..*CodeableConceptClassification of type of observation
                                  Binding: ?? (preferred): Codes for high level observation categories.


                                  • Elements differ in short: '(USCDI) Classification of type of observation' vs 'Classification of type of observation'
                                  • Element minimum cardinalities differ: '1' vs '0'
                                  .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                    .... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                    Slice: Unordered, Open by value:url
                                    0..*ExtensionAdditional content defined by implementations
                                    Slice: Unordered, Open by value:url
                                      .... coding Σ0..*CodingCode defined by a terminology system
                                      Σ0..*CodingCode defined by a terminology system

                                      Required Pattern: {"system":"http://terminology.hl7.org/CodeSystem/observation-category","code":"social-history"}
                                        .... text Σ0..1stringPlain text representation of the conceptΣ0..1stringPlain text representation of the concept
                                          ... code SΣ1..1CodeableConcept(USCDI) Oxygen Saturation by Pulse Oximetry
                                          Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                          SΣ1..1CodeableConceptType of observation (code / type)
                                          Binding: ?? (example): Codes identifying names of simple observations.


                                          Required Pattern: {"coding":[{"system":"http://loinc.org","code":"11341-5","display":"History of Occupation"}]}
                                          • Elements differ in short: '(USCDI) Oxygen Saturation by Pulse Oximetry' vs 'Type of observation (code / type)'
                                          • Elements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation "name".'
                                          • Elements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood).' vs '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
                                          • Elements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
                                          • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                          .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                            .... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                            Slice: Unordered, Open by value:url
                                            0..*ExtensionAdditional content defined by implementations
                                            Slice: Unordered, Open by value:url
                                              .... Slices for coding SΣ2..*Coding(USCDI) Code defined by a terminology system
                                              Slice: Unordered, Open by pattern:$this
                                              Σ0..*CodingCode defined by a terminology system
                                              • Elements differ in short: '(USCDI) Code defined by a terminology system' vs 'Code defined by a terminology system'
                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                              • Element minimum cardinalities differ: '2' vs '0'
                                              .... text Σ0..1stringPlain text representation of the conceptΣ0..1stringPlain text representation of the concept
                                                ... subject SΣ1..1Reference(US Core Patient Profile)(USCDI) Who and/or what the observation is aboutSΣ1..1Reference(US Veteran)Who and/or what the observation is about
                                                • Elements differ in short: '(USCDI) Who and/or what the observation is about' vs 'Who and/or what the observation is about'
                                                ... focus ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                                Σ0..0
                                                • Element maximum cardinalities differ: '2147483647' vs '0'
                                                ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..0
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... effective[x] SΣC1..1dateTime S, Period(USCDI) Often just a dateTime for Vital SignsΣ1..1PeriodClinically relevant time/time-period for observation
                                                Slice: Unordered, Closed by type:$this
                                                • Elements differ in short: '(USCDI) Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
                                                • Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                ... issued Σ0..1instantDate/Time this version was made availableΣ0..0
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                Σ0..0
                                                • Element maximum cardinalities differ: '2147483647' vs '0'
                                                ... Slices for value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period(USCDI) Vital Signs Value
                                                Slice: Unordered, Open by type:$this
                                                Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                ΣC1..1CodeableConceptActual result
                                                Slice: Unordered, Closed by type:$this
                                                • Elements differ in short: '(USCDI) Vital Signs Value' vs 'Actual result'
                                                • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                • Element minimum cardinalities differ: '0' vs '1'
                                                ... dataAbsentReason SC0..1CodeableConcept(USCDI) Why the result is missing
                                                Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                C0..0
                                                • Elements differ in short: '(USCDI) Why the result is missing' vs 'Why the result is missing'
                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                0..0
                                                • Element maximum cardinalities differ: '2147483647' vs '0'
                                                ... note 0..*AnnotationComments about the observation
                                                0..1AnnotationComments about the observation
                                                • Element maximum cardinalities differ: '2147483647' vs '1'
                                                ... bodySite 0..1CodeableConceptObserved body part
                                                Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                0..0
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... method 0..1CodeableConceptHow it was done
                                                Binding: ?? (example): Methods for simple observations.

                                                0..0
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... specimen 0..1Reference(Specimen)Specimen used for this observation0..0
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..0
                                                • Element maximum cardinalities differ: '1' vs '0'
                                                ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                                C0..*BackboneElementProvides guide for interpretation
                                                  .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                    .... extension 0..*ExtensionAdditional content defined by implementations
                                                    0..*ExtensionAdditional content defined by implementations
                                                      .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                      ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                        .... low C0..1??Low Range, if relevantC0..1??Low Range, if relevant
                                                          .... high C0..1??High Range, if relevantC0..1??High Range, if relevant
                                                            .... type 0..1CodeableConceptReference range qualifier
                                                            Binding: ?? (preferred): Code for the meaning of a reference range.

                                                            0..1CodeableConceptReference range qualifier
                                                            Binding: ?? (preferred): Code for the meaning of a reference range.

                                                              .... appliesTo 0..*CodeableConceptReference range population
                                                              Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                              0..*CodeableConceptReference range population
                                                              Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                  .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                    ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                    Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
                                                                    • Elements differ in short: 'Used when reporting vital signs panel components' vs 'Related resource that belongs to the Observation group'
                                                                    • Elements differ in definition: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
                                                                    • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                    ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                    Σ0..0
                                                                    • Element maximum cardinalities differ: '2147483647' vs '0'
                                                                    ... Slices for component SΣC0..*BackboneElement(USCDI) Used when reporting flow rates or oxygen concentration.
                                                                    Slice: Unordered, Open by pattern:code
                                                                    SΣ0..*BackboneElementComponent results
                                                                    Slice: Unordered, Open by pattern:code
                                                                    • Elements differ in short: '(USCDI) Used when reporting flow rates or oxygen concentration.' vs 'Component results'
                                                                    • Elements differ in definition: 'Used when reporting flow rates or oxygen concentration.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
                                                                    .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                      .... extension 0..*ExtensionAdditional content defined by implementations
                                                                      0..*ExtensionAdditional content defined by implementations
                                                                        .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                        ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                          .... code SΣ1..1CodeableConcept(USCDI) Type of component observation (code / type)
                                                                          Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                                                          Σ1..1CodeableConceptType of component observation (code / type)
                                                                          Binding: ?? (example): Codes identifying names of simple observations.

                                                                          • Elements differ in short: '(USCDI) Type of component observation (code / type)' vs 'Type of component observation (code / type)'
                                                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                          • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                                                          .... value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period(USCDI) Vital Sign Component Value
                                                                          Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                                          Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                                          • Elements differ in short: '(USCDI) Vital Sign Component Value' vs 'Actual component result'
                                                                          • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                                          • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                          .... dataAbsentReason SC0..1CodeableConcept(USCDI) Why the component result is missing
                                                                          Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                          C0..1CodeableConceptWhy the component result is missing
                                                                          Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                          • Elements differ in short: '(USCDI) Why the component result is missing' vs 'Why the component result is missing'
                                                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                          .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                          Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                          0..*CodeableConceptHigh, low, normal, etc.
                                                                          Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                            .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                            0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                              doco Documentation for this format