Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/head-occipital-frontal-circumference-percentile vs http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-primary-tumor-category

Left:US Core Pediatric Head Occipital-frontal Circumference Percentile Profile (http://hl7.org/fhir/us/core/StructureDefinition/head-occipital-frontal-circumference-percentile)
Right:TNM Primary Tumor Category Profile (http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-primary-tumor-category)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/head-occipital-frontal-circumference-percentile' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-primary-tumor-category'
ErrorStructureDefinition.versionValues for version differ: '4.1.0' vs '2.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCorePediatricHeadOccipitalFrontalCircumferencePercentileProfile' vs 'TNMPrimaryTumorCategory'
InformationStructureDefinition.titleValues for title differ: 'US Core Pediatric Head Occipital-frontal Circumference Percentile Profile' vs 'TNM Primary Tumor Category Profile'
InformationStructureDefinition.dateValues for date differ: '2020-11-18' vs '2022-01-18T03:17:40+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International Clinical Interoperability Council'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Pediatric Head Occipital-frontal Circumference Percentile Profile' vs 'Measurements and simple assertions'
WarningObservationElements differ in definition: 'Defines constraints on the Observation resource to represent head occipital-frontal circumference percentile for patients from birth to 36 months of age in FHIR using a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.' vs 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservation.categoryElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.categoryElement minimum cardinalities differ: '1' vs '0'
WarningObservation.codeElements differ in short: 'Head Occipital-frontal circumference Percentile' vs 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.subjectElements differ in definition: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'The patient associated with staging data.'
InformationObservation.subjectElement minimum cardinalities differ: '1' vs '0'
WarningObservation.focusElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
InformationObservation.effective[x]Element minimum cardinalities differ: '1' vs '0'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' vs 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.methodElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.deviceElements differ in short: '(Measurement) Device' vs 'Not used in this profile'
WarningObservation.deviceElements differ in definition: 'The device used to generate the observation data.' vs 'Not used in this profile'
WarningObservation.referenceRangeElements differ in short: 'Provides guide for interpretation' vs 'Not used in this profile'
WarningObservation.referenceRangeElements differ in definition: 'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.' vs 'Not used in this profile'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' vs 'Not used in this profile'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' vs 'Not used in this profile'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Component observations' vs 'Not used in this profile'
WarningObservation.componentElements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Not used in this profile'
WarningObservation.componentElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2020-11-182022-01-18T03:17:40+00:00
    • Values Differ
    .descriptionDefines constraints on the Observation resource to represent head occipital-frontal circumference percentile for patients from birth to 36 months of age in FHIR using a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.Category of the primary tumor, based on its size and extent, based on evidence such as physical examination, imaging, and/or biopsy.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCorePediatricHeadOccipitalFrontalCircumferencePercentileProfileTNMPrimaryTumorCategory
            • Values Differ
            .publisherHL7 International - Cross-Group ProjectsHL7 International Clinical Interoperability Council
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Pediatric Head Occipital-frontal Circumference Percentile ProfileTNM Primary Tumor Category Profile
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/head-occipital-frontal-circumference-percentilehttp://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-primary-tumor-category
                  • Values Differ
                  .version4.1.02.0.0
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation I0..*USCoreVitalSignsProfileUS Core Pediatric Head Occipital-frontal Circumference Percentile Profile
                  I0..*ObservationMeasurements and simple assertions
                  • Elements differ in short: 'US Core Pediatric Head Occipital-frontal Circumference Percentile Profile' vs 'Measurements and simple assertions'
                  • Elements differ in definition: 'Defines constraints on the Observation resource to represent head occipital-frontal circumference percentile for patients from birth to 36 months of age in FHIR using a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.' vs 'Measurements and simple assertions made about a patient, device or other subject.'
                  ... id Σ0..1stringLogical id of this artifactΣ0..1stringLogical id of this artifact
                    ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                      ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                        ... language 0..1codeLanguage of the resource content
                        Binding: CommonLanguages (preferred)
                        Max Binding: AllLanguages: A human language.

                        0..1codeLanguage of the resource content
                        Binding: CommonLanguages (preferred)
                        Max Binding: AllLanguages: A human language.

                          ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                            ... contained 0..*ResourceContained, inline Resources
                            0..*ResourceContained, inline Resources
                              ... extension 0..*ExtensionAdditional content defined by implementations
                              0..*ExtensionAdditional content defined by implementations
                                ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                ?!0..*ExtensionExtensions that cannot be ignored
                                  ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                  Σ0..*IdentifierBusiness Identifier for observation
                                    ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                    Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                      ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                      Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                        ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                        Binding: ObservationStatus (required)
                                        ?!SΣ1..1coderegistered | preliminary | final | amended +
                                        Binding: ObservationStatus (required): Codes providing the status of an observation.

                                          ... Slices for category S1..*CodeableConceptClassification of type of observation
                                          Slice: Unordered, Open by value:coding.code, value:coding.system
                                          Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


                                          0..*CodeableConceptClassification of type of observation
                                          Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                          • Element minimum cardinalities differ: '1' vs '0'
                                          ... code SΣ1..1CodeableConceptHead Occipital-frontal circumference Percentile
                                          Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


                                          Required Pattern: {"coding":[{"system":"http://loinc.org","code":"8289-1"}]}
                                          SΣ1..1CodeableConceptType of observation (code / type)
                                          Binding: Staging Type for Primary Tumor Category Value Set (required)
                                          • Elements differ in short: 'Head Occipital-frontal circumference Percentile' vs 'Type of observation (code / type)'
                                          • Elements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation "name".'
                                          • Elements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
                                          ... subject SΣ1..1Reference(US Core Patient Profile)Who and/or what the observation is aboutSΣ0..1Reference(Cancer Patient Profile)Who and/or what the observation is about
                                          • Elements differ in definition: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'The patient associated with staging data.'
                                          • Element minimum cardinalities differ: '1' vs '0'
                                          ... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                          SΣ0..*Reference(Primary Cancer Condition Profile)What the observation is about, when it is not about the subject of record
                                          • Elements differ in definition for mustSupport: 'false' vs 'true'
                                          ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                            ... effective[x] SΣI1..1dateTime S, PeriodOften just a dateTime for Vital SignsSΣ0..1dateTime, Period, Timing, instantClinically relevant time/time-period for observation
                                            • Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
                                            • Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
                                            • Element minimum cardinalities differ: '1' vs '0'
                                            ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                              ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                              Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                ... Slices for value[x] SΣI0..1QuantityVital Signs Value
                                                Slice: Unordered, Closed by type:$this
                                                Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

                                                SΣI0..1CodeableConceptActual result
                                                Binding: TNM Primary Tumor Category Value Set (preferred)
                                                • Elements differ in short: 'Vital Signs Value' vs 'Actual result'
                                                • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                ... dataAbsentReason SI0..1CodeableConceptWhy the result is missing
                                                Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                I0..1CodeableConceptWhy the result is missing
                                                Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                0..*CodeableConceptHigh, low, normal, etc.
                                                Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                  ... note 0..*AnnotationComments about the observation
                                                  0..*AnnotationComments about the observation
                                                    ... bodySite 0..1CodeableConceptObserved body part
                                                    Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

                                                    0..1CodeableConceptObserved body part
                                                    Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

                                                      ... method 0..1CodeableConceptHow it was done
                                                      Binding: ObservationMethods (example): Methods for simple observations.

                                                      S0..1CodeableConceptHow it was done
                                                      Binding: Cancer Staging System Value Set (extensible)
                                                      • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                      ... specimen 0..1Reference(Specimen)Specimen used for this observation0..1Reference(Specimen)Specimen used for this observation
                                                        ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)Not used in this profile
                                                        • Elements differ in short: '(Measurement) Device' vs 'Not used in this profile'
                                                        • Elements differ in definition: 'The device used to generate the observation data.' vs 'Not used in this profile'
                                                        ... referenceRange I0..*BackboneElementProvides guide for interpretation
                                                        obs-3: Must have at least a low or a high or text
                                                        I0..*BackboneElementNot used in this profile
                                                        • Elements differ in short: 'Provides guide for interpretation' vs 'Not used in this profile'
                                                        • Elements differ in definition: 'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two `referenceRange` elements would be used.' vs 'Not used in this profile'
                                                        .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                          .... extension 0..*ExtensionAdditional content defined by implementations
                                                          0..*ExtensionAdditional content defined by implementations
                                                            .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                            ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                              .... low I0..1SimpleQuantityLow Range, if relevantI0..1SimpleQuantityLow Range, if relevant
                                                                .... high I0..1SimpleQuantityHigh Range, if relevantI0..1SimpleQuantityHigh Range, if relevant
                                                                  .... type 0..1CodeableConceptReference range qualifier
                                                                  Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

                                                                  0..1CodeableConceptReference range qualifier
                                                                  Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

                                                                    .... appliesTo 0..*CodeableConceptReference range population
                                                                    Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


                                                                    0..*CodeableConceptReference range population
                                                                    Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


                                                                      .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                        .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                          ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                          Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Not used in this profile
                                                                          • Elements differ in short: 'Used when reporting vital signs panel components' vs 'Not used in this profile'
                                                                          • Elements differ in definition: 'Used when reporting vital signs panel components.' vs 'Not used in this profile'
                                                                          • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                          ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                          Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
                                                                            ... component SΣI0..*BackboneElementComponent observations
                                                                            Σ0..*BackboneElementNot used in this profile
                                                                            • Elements differ in short: 'Component observations' vs 'Not used in this profile'
                                                                            • Elements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Not used in this profile'
                                                                            • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                            .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                              .... extension 0..*ExtensionAdditional content defined by implementations
                                                                              0..*ExtensionAdditional content defined by implementations
                                                                                .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                  .... code SΣ1..1CodeableConceptType of component observation (code / type)
                                                                                  Binding: US Core Vital Signs ValueSet (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                                                                  Σ1..1CodeableConceptType of component observation (code / type)
                                                                                  Binding: LOINCCodes (example): Codes identifying names of simple observations.

                                                                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                  • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                                                                  .... value[x] SΣI0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Component Value
                                                                                  Binding: VitalSignsUnits (extensible): Common UCUM units for recording Vital Signs.

                                                                                  Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                                                  • Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
                                                                                  • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                                                  • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                  .... dataAbsentReason SI0..1CodeableConceptWhy the component result is missing
                                                                                  Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                  I0..1CodeableConceptWhy the component result is missing
                                                                                  Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                  .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                                  Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                                                  0..*CodeableConceptHigh, low, normal, etc.
                                                                                  Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


                                                                                    .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                                    0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                                      doco Documentation for this format