Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate vs http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status

Left:US Core Heart Rate Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate)
Right:Karnofsky Performance Status Profile (http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status'
ErrorStructureDefinition.versionValues for version differ: '6.0.0-ballot' vs '2.1.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreHeartRateProfile' vs 'KarnofskyPerformanceStatus'
InformationStructureDefinition.titleValues for title differ: 'US Core Heart Rate Profile' vs 'Karnofsky Performance Status Profile'
InformationStructureDefinition.dateValues for date differ: '2022-04-20' vs '2023-03-21T04:50:14+11:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International Clinical Interoperability Council'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
WarningObservationElements differ in short: 'US Core Heart Rate Profile' vs 'Measurements and simple assertions'
WarningObservationElements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservationElements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
ErrorObservation.basedOnType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan], CanonicalType[http://hl7.org/fhir/StructureDefinition/DeviceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/NutritionOrder], CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan]])
ErrorObservation.partOfType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationAdministration], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationDispense], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationStatement], CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure], CanonicalType[http://hl7.org/fhir/StructureDefinition/Immunization], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure]])
WarningObservation.categoryElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.codeElements differ in short: 'Heart Rate' vs 'Type of observation (code / type)'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.subjectElements differ in definition: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'Patient whose performance status is recorded.'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
InformationObservation.effective[x]Element minimum cardinalities differ: '1' vs '0'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' vs 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.interpretationElements differ in definition for mustSupport: 'false' vs 'true'
ErrorObservation.interpretationUnable to resolve right value set http://loinc.org/vs/LL4986-7 at Observation.interpretation
WarningObservation.bodySiteElements differ in short: 'Observed body part' vs 'Not used in this profile'
WarningObservation.bodySiteElements differ in definition: 'Indicates the site on the subject's body where the observation was made (i.e. the target site).' vs 'Not used in this profile'
WarningObservation.specimenElements differ in short: 'Specimen used for this observation' vs 'Not used in this profile'
WarningObservation.specimenElements differ in definition: 'The specimen that was used when this observation was made.' vs 'Not used in this profile'
WarningObservation.deviceElements differ in short: '(Measurement) Device' vs 'Not used in this profile'
WarningObservation.deviceElements differ in definition: 'The device used to generate the observation data.' vs 'Not used in this profile'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' vs 'Not used in this profile'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' vs 'Not used in this profile'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Component observations' vs 'Not used in this profile'
WarningObservation.componentElements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Not used in this profile'
WarningObservation.componentElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2022-04-202023-03-21T04:50:14+11:00
    • Values Differ
    .descriptionTo promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch heart rate observations with a standard LOINC code and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies the *additional* mandatory core elements, extensions, vocabularies and value sets which **SHALL** be present in the Observation resource when using this profile. It provides the floor for standards development for specific use cases.The Karnofsky Performance Status (KPS) is a tool used to measure a patient's functional status. It can be used to compare the effectiveness of different therapies and to help assess the prognosis of certain patients, such as those with certain cancers. The KPS score ranges from 0 to 100 in intervals of 10. Higher scores are associated with better functional status, with 100 representing no symptoms or evidence of disease, and 0 representing death.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCoreHeartRateProfileKarnofskyPerformanceStatus
            • Values Differ
            .publisherHL7 International - Cross-Group ProjectsHL7 International Clinical Interoperability Council
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Heart Rate ProfileKarnofsky Performance Status Profile
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-ratehttp://hl7.org/fhir/us/mcode/StructureDefinition/mcode-karnofsky-performance-status
                  • Values Differ
                  .version6.0.0-ballot2.1.0
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation C0..*USCoreVitalSignsProfileUS Core Heart Rate Profile
                  C0..*ObservationMeasurements and simple assertions
                  • Elements differ in short: 'US Core Heart Rate Profile' vs 'Measurements and simple assertions'
                  • Elements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
                  • Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
                  ... id Σ0..1idLogical id of this artifactΣ0..1idLogical id of this artifact
                    ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                      ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                        ... language 0..1codeLanguage of the resource content
                        Binding: ?? (preferred): A human language.

                        Additional BindingsPurpose
                        ??Max Binding
                        0..1codeLanguage of the resource content
                        Binding: ?? (preferred): A human language.

                        Additional BindingsPurpose
                        ??Max Binding
                          ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                            ... contained 0..*ResourceContained, inline Resources
                            0..*ResourceContained, inline Resources
                              ... extension 0..*ExtensionAdditional content defined by implementations
                              0..*ExtensionAdditional content defined by implementations
                                ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                ?!0..*ExtensionExtensions that cannot be ignored
                                  ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                  Σ0..*IdentifierBusiness Identifier for observation
                                    ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                    Σ0..*Reference(ServiceRequest | CarePlan)Fulfills plan, proposal or order
                                    • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan], CanonicalType[http://hl7.org/fhir/StructureDefinition/DeviceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/NutritionOrder], CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/ServiceRequest], CanonicalType[http://hl7.org/fhir/StructureDefinition/CarePlan]])
                                    ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                    Σ0..*Reference(Procedure)Part of referenced event
                                    • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationAdministration], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationDispense], CanonicalType[http://hl7.org/fhir/StructureDefinition/MedicationStatement], CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure], CanonicalType[http://hl7.org/fhir/StructureDefinition/Immunization], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Procedure]])
                                    ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                    Binding: ?? (required)
                                    ?!SΣ1..1coderegistered | preliminary | final | amended +
                                    Binding: ?? (required): Codes providing the status of an observation.

                                      ... Slices for category S1..*CodeableConceptClassification of type of observation
                                      Slice: Unordered, Open by value:coding.code, value:coding.system
                                      Binding: ?? (preferred): Codes for high level observation categories.


                                      1..*CodeableConceptClassification of type of observation
                                      Slice: Unordered, Open by pattern:$this
                                      Binding: ?? (preferred): Codes for high level observation categories.


                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                      ... code SΣ1..1CodeableConceptHeart Rate
                                      Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


                                      Required Pattern: {"coding":[{"system":"http://loinc.org","code":"8867-4"}]}
                                      SΣ1..1CodeableConceptType of observation (code / type)
                                      Binding: ?? (example): Codes identifying names of simple observations.


                                      Required Pattern: {"coding":[{"system":"http://loinc.org","code":"89243-0"}]}
                                      • Elements differ in short: 'Heart Rate' vs 'Type of observation (code / type)'
                                      • Elements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation "name".'
                                      • Elements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
                                      • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                      ... subject SΣ1..1Reference(US Core Patient Profile)Who and/or what the observation is aboutSΣ1..1Reference(Cancer Patient Profile)Who and/or what the observation is about
                                      • Elements differ in definition: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'Patient whose performance status is recorded.'
                                      ... focus ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                      ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                        ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                          ... effective[x] SΣC1..1dateTime S, PeriodOften just a dateTime for Vital SignsSΣ0..1dateTime, PeriodClinically relevant time/time-period for observation
                                          • Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
                                          • Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
                                          • Element minimum cardinalities differ: '1' vs '0'
                                          ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                            ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                            Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                              ... Slices for value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Signs Value
                                              Slice: Unordered, Open by type:$this
                                              Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                              SΣC0..1integerActual result
                                              • Elements differ in short: 'Vital Signs Value' vs 'Actual result'
                                              • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                              • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                              ... dataAbsentReason SC0..1CodeableConceptWhy the result is missing
                                              Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                              C0..1CodeableConceptWhy the result is missing
                                              Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                              ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                              Binding: ?? (extensible): Codes identifying interpretations of observations.


                                              S0..*CodeableConceptHigh, low, normal, etc.
                                              Binding: ?? (required)
                                              • Elements differ in definition for mustSupport: 'false' vs 'true'
                                              • Unable to resolve right value set http://loinc.org/vs/LL4986-7 at Observation.interpretation
                                              ... note 0..*AnnotationComments about the observation
                                              0..*AnnotationComments about the observation
                                                ... bodySite 0..1CodeableConceptObserved body part
                                                Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                0..1CodeableConceptNot used in this profile
                                                Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                • Elements differ in short: 'Observed body part' vs 'Not used in this profile'
                                                • Elements differ in definition: 'Indicates the site on the subject's body where the observation was made (i.e. the target site).' vs 'Not used in this profile'
                                                ... method 0..1CodeableConceptHow it was done
                                                Binding: ?? (example): Methods for simple observations.

                                                0..1CodeableConceptHow it was done
                                                Binding: ?? (example): Methods for simple observations.

                                                  ... specimen 0..1Reference(Specimen)Specimen used for this observation0..1Reference(Specimen)Not used in this profile
                                                  • Elements differ in short: 'Specimen used for this observation' vs 'Not used in this profile'
                                                  • Elements differ in definition: 'The specimen that was used when this observation was made.' vs 'Not used in this profile'
                                                  ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)Not used in this profile
                                                  • Elements differ in short: '(Measurement) Device' vs 'Not used in this profile'
                                                  • Elements differ in definition: 'The device used to generate the observation data.' vs 'Not used in this profile'
                                                  ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                                  C0..*BackboneElementProvides guide for interpretation
                                                    .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                      .... extension 0..*ExtensionAdditional content defined by implementations
                                                      0..*ExtensionAdditional content defined by implementations
                                                        .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                        ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                          .... low C0..1??Low Range, if relevantC0..1??Low Range, if relevant
                                                            .... high C0..1??High Range, if relevantC0..1??High Range, if relevant
                                                              .... type 0..1CodeableConceptReference range qualifier
                                                              Binding: ?? (preferred): Code for the meaning of a reference range.

                                                              0..1CodeableConceptReference range qualifier
                                                              Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                .... appliesTo 0..*CodeableConceptReference range population
                                                                Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                0..*CodeableConceptReference range population
                                                                Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                  .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                    .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                      ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                      Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Not used in this profile
                                                                      • Elements differ in short: 'Used when reporting vital signs panel components' vs 'Not used in this profile'
                                                                      • Elements differ in definition: 'Used when reporting vital signs panel components.' vs 'Not used in this profile'
                                                                      • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                      ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                      Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
                                                                        ... component SΣC0..*BackboneElementComponent observations
                                                                        Σ0..*BackboneElementNot used in this profile
                                                                        • Elements differ in short: 'Component observations' vs 'Not used in this profile'
                                                                        • Elements differ in definition: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Not used in this profile'
                                                                        • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                        .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                          .... extension 0..*ExtensionAdditional content defined by implementations
                                                                          0..*ExtensionAdditional content defined by implementations
                                                                            .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                            ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                              .... code SΣ1..1CodeableConceptType of component observation (code / type)
                                                                              Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                                                              Σ1..1CodeableConceptType of component observation (code / type)
                                                                              Binding: ?? (example): Codes identifying names of simple observations.

                                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                              • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                                                              .... value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Component Value
                                                                              Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                                              Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                                              • Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
                                                                              • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                                              • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                              .... dataAbsentReason SC0..1CodeableConceptWhy the component result is missing
                                                                              Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                              C0..1CodeableConceptWhy the component result is missing
                                                                              Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                              .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                              Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                              0..*CodeableConceptHigh, low, normal, etc.
                                                                              Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                                0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                                  doco Documentation for this format