Left: | US Core Heart Rate Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate) |
Right: | Genomic Variant Profile (http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-genomic-variant) |
Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-genomic-variant' |
Error | StructureDefinition.version | Values for version differ: '7.0.0-ballot' vs '4.0.0-ballot' |
Information | StructureDefinition.name | Values for name differ: 'USCoreHeartRateProfile' vs 'GenomicVariant' |
Information | StructureDefinition.title | Values for title differ: 'US Core Heart Rate Profile' vs 'Genomic Variant Profile' |
Information | StructureDefinition.date | Values for date differ: '2023-10-17' vs '2024-04-10T14:01:17+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International / Cross-Group Projects' vs 'HL7 International / Clinical Interoperability Council' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/uv/genomics-reporting/StructureDefinition/variant' |
Information | StructureDefinition.short | Values for short differ: 'US Core Heart Rate Profile' vs 'Variant' |
Information | StructureDefinition.definition | Values for definition differ: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.' |
Information | StructureDefinition.comment | Values for comment differ: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.' |
Information | StructureDefinition.short | Values for short differ: 'Additional content defined by implementations' vs 'Extension' |
Information | StructureDefinition.definition | Values for definition differ: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' |
Information | StructureDefinition.comment | Values for comment differ: 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below for guidance on referencing another Observation.' vs 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below for guidance on referencing another Observation.' |
Information | StructureDefinition.short | Values for short differ: 'Heart Rate' vs '69548-6' |
Information | StructureDefinition.definition | Values for definition differ: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.' |
Information | StructureDefinition.requirements | Values for requirements differ: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.' |
Information | Observation.subject | Element minimum cardinalities differ: '1' vs '0' |
Information | StructureDefinition.comment | Values for comment differ: 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/extension-observation-focuscode.html).' vs 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/R4/extension-observation-focuscode.html).' |
Information | StructureDefinition.short | Values for short differ: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation' |
Information | StructureDefinition.definition | Values for definition differ: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' |
Information | StructureDefinition.comment | Values for comment differ: 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/R4/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' |
Information | Observation.effective[x] | Element minimum cardinalities differ: '1' vs '0' |
Information | StructureDefinition.comment | Values for comment differ: 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' vs 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/R4/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' |
Information | StructureDefinition.short | Values for short differ: 'Vital Signs Value' vs 'Actual result' |
Information | StructureDefinition.definition | Values for definition differ: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.' |
Information | StructureDefinition.comment | Values for comment differ: 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' vs 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Information | StructureDefinition.short | Values for short differ: 'Comments about the observation' vs 'Comments about the Observation that also contain a coded type' |
Information | StructureDefinition.definition | Values for definition differ: 'Comments about the observation or the results.' vs 'A text note which also contains information about who made the statement and when.' |
Information | StructureDefinition.comment | Values for comment differ: 'May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.' vs 'May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation. The CodedAnnotation data type, while not allowing for or intending to make the content computable, does allow the author to indicate the type of note. This does not replace the use of interpretation, value, or component values. One important note is that Annotation is a FHIR data type, this is **NOT** about annotations in the genomic context.' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Need to be able to provide free text additional information.' vs 'Need to be able to provide free text additional information. Notes SHALL NOT contain information which can be captured in a structured way.' |
Information | StructureDefinition.comment | Values for comment differ: 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/extension-bodysite.html).' vs 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/R4/extension-bodysite.html).' |
Information | StructureDefinition.short | Values for short differ: 'How it was done' vs 'Sequencing | SNP array | PCR | Computational analysis | ...' |
Warning | Observation.method | Elements differ in definition for mustSupport: 'false' vs 'true' |
Warning | Observation.specimen | Elements differ in definition for mustSupport: 'false' vs 'true' |
Information | StructureDefinition.short | Values for short differ: 'Provides guide for interpretation' vs 'Not used in this profile' |
Information | StructureDefinition.definition | Values for definition differ: 'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.' vs 'Not used in this profile' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' |
Information | StructureDefinition.short | Values for short differ: 'Used when reporting vital signs panel components' vs 'Not used in this profile' |
Information | StructureDefinition.definition | Values for definition differ: 'Used when reporting vital signs panel components.' vs 'Not used in this profile' |
Information | StructureDefinition.comment | Values for comment differ: 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/questionnaireresponse.html) into a final score and represent the score as an Observation.' vs 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/R4/questionnaireresponse.html) into a final score and represent the score as an Observation.' |
Error | Observation.hasMember | Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) |
Information | StructureDefinition.comment | Values for comment differ: 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below.' vs 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below.' |
Information | StructureDefinition.short | Values for short differ: 'Component observations' vs 'Component results' |
Information | StructureDefinition.definition | Values for definition differ: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' |
Information | StructureDefinition.comment | Values for comment differ: 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/observation.html#notes) below.' vs 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/R4/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' |
Warning | Observation.component.code | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: 'Vital Sign Component Value' vs 'Actual component result' |
Information | StructureDefinition.definition | Values for definition differ: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.' |
Information | StructureDefinition.comment | Values for comment differ: 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' vs 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Warning | Observation.component.value[x] | Elements differ in definition for mustSupport: 'true' vs 'false' |
Warning | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport: 'true' vs 'false' |
Name | Value | Comments | |
---|---|---|---|
abstract | false | ||
baseDefinition | http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs | http://hl7.org/fhir/uv/genomics-reporting/StructureDefinition/variant |
|
copyright | Used by permission of HL7 International, all rights reserved Creative Commons License |
| |
date | 2023-10-17 | 2024-04-10T14:01:17+00:00 |
|
description | To promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch heart rate observations with a standard LOINC code and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies which *additional* core elements, extensions, vocabularies, and value sets **SHALL** be present and constrains the way the elements are used when using the profile. It provides the floor for standards development for specific use cases. | Details about a set of changes in the tested sample compared to a reference sequence. The term variant can be used to describe an alteration that may be benign, pathogenic, or of unknown significance. The term variant is increasingly being used in place of the term mutation. Variants can be computed relative to reference sequence assembly from which it was identified. |
|
experimental | false |
| |
fhirVersion | 4.0.1 | ||
jurisdiction | |||
jurisdiction[0] | urn:iso:std:iso:3166#US | ||
kind | resource | ||
name | USCoreHeartRateProfile | GenomicVariant |
|
publisher | HL7 International / Cross-Group Projects | HL7 International / Clinical Interoperability Council |
|
purpose | |||
status | active | ||
title | US Core Heart Rate Profile | Genomic Variant Profile |
|
type | Observation | ||
url | http://hl7.org/fhir/us/core/StructureDefinition/us-core-heart-rate | http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-genomic-variant |
|
version | 7.0.0-ballot | 4.0.0-ballot |
|
Name | L Flags | L Card. | L Type | L Description & Constraints | R Flags | R Card. | R Type | R Description & Constraints | Comments | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreVitalSignsProfile | US Core Heart Rate Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | C | 0..* | Variant | Variant obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present | |||||||||
id | Σ | 0..1 | id | Logical id of this artifact | Σ | 0..1 | id | Logical id of this artifact | |||||||||
meta | Σ | 0..1 | Meta | Metadata about the resource | Σ | 0..1 | Meta | Metadata about the resource | |||||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ?!Σ | 0..1 | uri | A set of rules under which this content was created | |||||||||
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
| 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
| |||||||||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||||||||
contained | 0..* | Resource | Contained, inline Resources | 0..* | Resource | Contained, inline Resources | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ?! | 0..* | Extension | Extensions that cannot be ignored | |||||||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | Σ | 0..* | Identifier | Business Identifier for observation | |||||||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | |||||||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | |||||||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required) | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required): Codes providing the status of an observation. | |||||||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ?? (preferred): Codes for high level observation categories. | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding Binding: ?? (preferred): Codes for high level observation categories. | |||||||||
code | SΣ | 1..1 | CodeableConcept | Heart Rate Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. Required Pattern: {"coding":[{"system":"http://loinc.org","code":"8867-4"}]} | SΣ | 1..1 | CodeableConcept | 69548-6 Binding: ?? (example): Codes identifying names of simple observations. Required Pattern: {"coding":[{"system":"http://loinc.org","code":"69548-6"}]} | |||||||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about | SΣ | 0..1 | Reference(Cancer Patient Profile) | Who and/or what the observation is about |
| ||||||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | |||||||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made | |||||||||
effective[x] | SΣC | 1..1 | dateTime S, Period | Often just a dateTime for Vital Signs vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day | SΣ | 0..1 | dateTime, Period, Timing, instant | Clinically relevant time/time-period for observation Slice: Unordered, Open by type:$this |
| ||||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | Σ | 0..1 | instant | Date/Time this version was made available | |||||||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | |||||||||
Slices for value[x] | SΣC | 0..1 | Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Signs Value Slice: Unordered, Open by type:$this Binding: ?? (extensible): Common UCUM units for recording Vital Signs. | SΣC | 0..1 | CodeableConcept | Actual result Slice: Unordered, Closed by type:$this | |||||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | SC | 0..1 | CodeableConcept | Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | |||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | |||||||||||
note | 0..* | Annotation | Comments about the observation | 0..* | ?? | Comments about the Observation that also contain a coded type | |||||||||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: ?? (example): Codes describing anatomical locations. May include laterality. | 0..1 | CodeableConcept | Observed body part Binding: ?? (example): Codes describing anatomical locations. May include laterality. | |||||||||||
method | 0..1 | CodeableConcept | How it was done Binding: ?? (example): Methods for simple observations. | S | 0..1 | CodeableConcept | Sequencing | SNP array | PCR | Computational analysis | ... Binding: ?? (extensible) |
| |||||||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | S | 0..1 | Reference(Human Specimen Profile) | Specimen used for this observation |
| |||||||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||||||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text | C | 0..* | BackboneElement | Not used in this profile obs-3: Must have at least a low or a high or text | |||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
low | C | 0..1 | ?? | Low Range, if relevant | C | 0..1 | ?? | Low Range, if relevant | |||||||||
high | C | 0..1 | ?? | High Range, if relevant | C | 0..1 | ?? | High Range, if relevant | |||||||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. | |||||||||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. | |||||||||||
age | 0..1 | Range | Applicable age range, if relevant | 0..1 | Range | Applicable age range, if relevant | |||||||||||
text | 0..1 | string | Text based reference range in an observation | 0..1 | string | Text based reference range in an observation | |||||||||||
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Not used in this profile |
| ||||||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | |||||||||
component | SΣC | 0..* | BackboneElement | Component observations vs-3: If there is no a value a data absent reason must be present | SΣ | 0..* | BackboneElement | Component results Slice: Unordered, Open by pattern:code | |||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs. | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: ?? (example): Codes identifying names of simple observations. |
| ||||||||
value[x] | SΣC | 0..1 | Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Component Value Binding: ?? (extensible): Common UCUM units for recording Vital Signs. | Σ | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result |
| ||||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | C | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
| ||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | |||||||||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||||||||
Documentation for this format |