This page is part of the HL7 FHIR Implementation Guide: minimal Common Oncology Data Elements (mCODE) Release 1 - US Realm | STU1 (v4.0.0-ballot: STU4 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 3.0.0. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/mcode/ValueSet/mcode-radiotherapy-technique-vs | Version: 4.0.0-ballot | |||
Active as of 2024-04-10 | Maturity Level: 3 | Computable Name: RadiotherapyTechniqueVS | ||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.15.48.56 | ||||
Copyright/Legal: This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement |
Codes describing the techniques of external beam and brachytherapy radiation procedures, for use with radiotherapy summaries. This is the union of the EBRT and brachytherapy technique value sets.
References
Changes since version true:
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/v3-NullFlavor
Code | Display | Definition |
UNC | un-encoded | **Description:** The actual value has not yet been encoded within the approved value domain. **Example**: Original text or a local code has been specified but translation or encoding to the approved value set has not yet occurred due to limitations of the sending system. Original text has been captured for a PQ, but not attempt has been made to split the value and unit or to encode the unit in UCUM. **Usage Notes**: If it is known that it is not possible to encode the concept, OTH should be used instead. However, use of UNC does not necessarily guarantee the concept will be encodable, only that encoding has not been attempted. Data type properties such as original text and translations may be present when this null flavor is included. |
Expansion based on:
This value set has 43 codes in it. In order to keep the publication size manageable, only a selection (18 codes) of the whole set of codes is shown.
Code | System | Display | Definition |
441799006 | http://snomed.info/sct | Intensity modulated radiation therapy | |
1156530009 | http://snomed.info/sct | VMAT - volumetric modulated arc therapy | |
1162782007 | http://snomed.info/sct | Three dimensional external beam radiation therapy (procedure) | |
1156526006 | http://snomed.info/sct | Two dimensional external beam radiation therapy (procedure) | |
168524008 | http://snomed.info/sct | Radiotherapy - intraoperative control | |
1163157007 | http://snomed.info/sct | FLASH radiotherapy | |
169317000 | http://snomed.info/sct | Neutron capture therapy | |
1156529004 | http://snomed.info/sct | External beam radiation therapy using particle passive scattering technique | |
1156528007 | http://snomed.info/sct | Particle spot scanning external beam radiotherapy | |
1204242009 | http://snomed.info/sct | External beam radiation therapy using particle scanning technique (procedure) | |
113120007 | http://snomed.info/sct | Interstitial brachytherapy | |
384692006 | http://snomed.info/sct | Intracavitary brachytherapy (procedure) | |
14473006 | http://snomed.info/sct | Surface brachytherapy | |
1156382005 | http://snomed.info/sct | Intensity modulated intracavitary brachytherapy | |
1156383000 | http://snomed.info/sct | Intravascular brachytherapy (procedure) | |
384691004 | http://snomed.info/sct | Intraluminal brachytherapy (procedure) | |
16560241000119104 | http://snomed.info/sct | Oral radionuclide therapy (procedure) | |
UNC | http://terminology.hl7.org/CodeSystem/v3-NullFlavor | un-encoded | Description: The actual value has not yet been encoded within the approved value domain. Example: Original text or a local code has been specified but translation or encoding to the approved value set has not yet occurred due to limitations of the sending system. Original text has been captured for a PQ, but not attempt has been made to split the value and unit or to encode the unit in UCUM. Usage Notes: If it is known that it is not possible to encode the concept, OTH should be used instead. However, use of UNC does not necessarily guarantee the concept will be encodable, only that encoding has not been attempted. Data type properties such as original text and translations may be present when this null flavor is included. |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |