Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry vs http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-regional-nodes-category

Left:US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry)
Right:TNM Regional Nodes Category Profile (http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-regional-nodes-category)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-regional-nodes-category'
ErrorStructureDefinition.versionValues for version differ: '6.0.0-ballot' vs '3.0.0-ballot'
InformationStructureDefinition.nameValues for name differ: 'USCorePulseOximetryProfile' vs 'TNMRegionalNodesCategory'
InformationStructureDefinition.titleValues for title differ: 'US Core Pulse Oximetry Profile' vs 'TNM Regional Nodes Category Profile'
InformationStructureDefinition.dateValues for date differ: '2022-04-20' vs '2023-03-28T19:28:28+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International - Cross-Group Projects' vs 'HL7 International Clinical Interoperability Council'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-stage-group'
WarningObservationElements differ in short: 'US Core Pulse Oximetry Profile' vs 'Measurements and simple assertions'
WarningObservationElements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
WarningObservationElements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
WarningObservation.categoryElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.categoryElement minimum cardinalities differ: '1' vs '0'
WarningObservation.codeElements differ in short: 'Oxygen Saturation by Pulse Oximetry' vs 'The type of stage information reported.'
WarningObservation.codeElements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'The type of staging performed, e.g., clinically by oncologist, by a pathologist on a specimen, or other method. This information is required, although it may be redundant with the stage code recorded in Observation.valueCodeableConcept (for example, the 'c' in cN0 represents clinical staging).'
WarningObservation.codeElements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood).' vs '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
WarningObservation.codeElements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.code.codingElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.subjectElements differ in definition: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'The patient associated with staging assessment.'
InformationObservation.subjectElement minimum cardinalities differ: '1' vs '0'
WarningObservation.focusElements differ in short: 'What the observation is about, when it is not about the subject of record' vs 'The cancer condition associated with staging assessment.'
WarningObservation.focusElements differ in definition: 'The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.' vs 'Staging is associated with a particular primary cancer condition. Observation.focus is used to point back to that condition.'
WarningObservation.focusElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.effective[x]Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
WarningObservation.effective[x]Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
InformationObservation.effective[x]Element minimum cardinalities differ: '1' vs '0'
WarningObservation.value[x]Elements differ in short: 'Vital Signs Value' vs 'Actual result'
WarningObservation.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.methodElements differ in definition for mustSupport: 'false' vs 'true'
InformationObservation.methodElement minimum cardinalities differ: '0' vs '1'
WarningObservation.deviceElements differ in short: '(Measurement) Device' vs 'Not used in this profile'
WarningObservation.deviceElements differ in definition: 'The device used to generate the observation data.' vs 'Not used in this profile'
WarningObservation.referenceRangeElements differ in short: 'Provides guide for interpretation' vs 'Not used in this profile'
WarningObservation.referenceRangeElements differ in definition: 'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an 'OR'. In other words, to represent two distinct target populations, two `referenceRange` elements would be used.' vs 'Not used in this profile'
WarningObservation.hasMemberElements differ in short: 'Used when reporting vital signs panel components' vs 'Not used in this profile'
WarningObservation.hasMemberElements differ in definition: 'Used when reporting vital signs panel components.' vs 'Not used in this profile'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
WarningObservation.componentElements differ in short: 'Used when reporting flow rates or oxygen concentration.' vs 'Component results'
WarningObservation.componentElements differ in definition: 'Used when reporting flow rates or oxygen concentration.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
WarningObservation.componentElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.codeElements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
WarningObservation.component.value[x]Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
WarningObservation.component.value[x]Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
WarningObservation.component.value[x]Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/us/mcode/StructureDefinition/mcode-cancer-stage-group
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2022-04-202023-03-28T19:28:28+00:00
    • Values Differ
    .descriptionTo promote interoperability and adoption through common implementation, this profile sets minimum expectations for the Observation resource to record, search, and fetch pulse oximetry and inspired oxygen observations with a standard LOINC codes and UCUM units of measure. It is based on the US Core Vital Signs Profile and identifies the *additional* mandatory core elements, extensions, vocabularies and value sets which **SHALL** be present in the Observation resource when using this profile. It provides the floor for standards development for specific use cases.Category of the presence or absence of metastases in regional lymph nodes, based on evidence such as physical examination, imaging, and/or biopsy.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCorePulseOximetryProfileTNMRegionalNodesCategory
            • Values Differ
            .publisherHL7 International - Cross-Group ProjectsHL7 International Clinical Interoperability Council
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Pulse Oximetry ProfileTNM Regional Nodes Category Profile
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetryhttp://hl7.org/fhir/us/mcode/StructureDefinition/mcode-tnm-regional-nodes-category
                  • Values Differ
                  .version6.0.0-ballot3.0.0-ballot
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.L TypeL Description & ConstraintsCommentsdoco
                  .. Observation C0..*USCoreVitalSignsProfileUS Core Pulse Oximetry Profile
                  C0..*CancerStageGroupMeasurements and simple assertions
                  • Elements differ in short: 'US Core Pulse Oximetry Profile' vs 'Measurements and simple assertions'
                  • Elements differ in definition: '\-' vs 'Measurements and simple assertions made about a patient, device or other subject.'
                  • Elements differ in comments: '\-' vs 'Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.'
                  ... id Σ0..1idLogical id of this artifactΣ0..1idLogical id of this artifact
                    ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                      ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                        ... language 0..1codeLanguage of the resource content
                        Binding: ?? (preferred): A human language.

                        Additional BindingsPurpose
                        ??Max Binding
                        0..1codeLanguage of the resource content
                        Binding: ?? (preferred): A human language.

                        Additional BindingsPurpose
                        ??Max Binding
                          ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                            ... contained 0..*ResourceContained, inline Resources
                            0..*ResourceContained, inline Resources
                              ... extension 0..*ExtensionAdditional content defined by implementations
                              0..*ExtensionAdditional content defined by implementations
                                ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                ?!0..*ExtensionExtensions that cannot be ignored
                                  ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                  Σ0..*IdentifierBusiness Identifier for observation
                                    ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                    Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                      ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                      Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                        ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                        Binding: ?? (required)
                                        ?!SΣ1..1coderegistered | preliminary | final | amended +
                                        Binding: ?? (required): Codes providing the status of an observation.

                                          ... Slices for category S1..*CodeableConceptClassification of type of observation
                                          Slice: Unordered, Open by value:coding.code, value:coding.system
                                          Binding: ?? (preferred): Codes for high level observation categories.


                                          0..*CodeableConceptClassification of type of observation
                                          Binding: ?? (preferred): Codes for high level observation categories.


                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                          • Element minimum cardinalities differ: '1' vs '0'
                                          ... code SΣ1..1CodeableConceptOxygen Saturation by Pulse Oximetry
                                          Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                          SΣ1..1CodeableConceptThe type of stage information reported.
                                          Binding: ?? (required)
                                          • Elements differ in short: 'Oxygen Saturation by Pulse Oximetry' vs 'The type of stage information reported.'
                                          • Elements differ in definition: 'Coded Responses from C-CDA Vital Sign Results.' vs 'The type of staging performed, e.g., clinically by oncologist, by a pathologist on a specimen, or other method. This information is required, although it may be redundant with the stage code recorded in Observation.valueCodeableConcept (for example, the 'c' in cN0 represents clinical staging).'
                                          • Elements differ in comments: 'The code (59408-5 Oxygen saturation in Arterial blood by Pulse oximetry) is included as an additional observation code to FHIR Core vital Oxygen Saturation code (2708-6 Oxygen saturation in Arterial blood).' vs '*All* code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.'
                                          • Elements differ in requirements: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
                                          .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                            .... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                            Slice: Unordered, Open by value:url
                                            0..*ExtensionAdditional content defined by implementations
                                            Slice: Unordered, Open by value:url
                                              .... Slices for coding SΣ0..*CodingCode defined by a terminology system
                                              Slice: Unordered, Open by pattern:$this
                                              Σ0..*CodingCode defined by a terminology system
                                              • Elements differ in definition for mustSupport: 'true' vs 'false'
                                              .... text Σ0..1stringPlain text representation of the conceptΣ0..1stringPlain text representation of the concept
                                                ... subject SΣ1..1Reference(US Core Patient Profile)Who and/or what the observation is aboutSΣ0..1Reference(Cancer Patient Profile)Who and/or what the observation is about
                                                • Elements differ in definition: 'The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the `focus` element or the `code` itself specifies the actual focus of the observation.' vs 'The patient associated with staging assessment.'
                                                • Element minimum cardinalities differ: '1' vs '0'
                                                ... focus ΣTU0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                                SΣ0..*Reference(Primary Cancer Condition Profile)The cancer condition associated with staging assessment.
                                                • Elements differ in short: 'What the observation is about, when it is not about the subject of record' vs 'The cancer condition associated with staging assessment.'
                                                • Elements differ in definition: 'The actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus.' vs 'Staging is associated with a particular primary cancer condition. Observation.focus is used to point back to that condition.'
                                                • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                                  ... effective[x] SΣC1..1dateTime S, PeriodOften just a dateTime for Vital SignsSΣ0..1dateTime, Period, Timing, instantClinically relevant time/time-period for observation
                                                  • Elements differ in short: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
                                                  • Elements differ in definition: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
                                                  • Element minimum cardinalities differ: '1' vs '0'
                                                  ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                                    ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                    Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                      ... Slices for value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Signs Value
                                                      Slice: Unordered, Open by type:$this
                                                      Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                      SΣC0..1CodeableConceptActual result
                                                      Binding: ?? (preferred)
                                                      Additional BindingsPurpose
                                                      ??Max Binding
                                                      • Elements differ in short: 'Vital Signs Value' vs 'Actual result'
                                                      • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                      • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                      ... dataAbsentReason SC0..1CodeableConceptWhy the result is missing
                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                      C0..1CodeableConceptWhy the result is missing
                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                      ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                      0..*CodeableConceptHigh, low, normal, etc.
                                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                        ... note 0..*AnnotationComments about the observation
                                                        0..*AnnotationComments about the observation
                                                          ... bodySite 0..1CodeableConceptObserved body part
                                                          Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                          0..1CodeableConceptObserved body part
                                                          Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                            ... method 0..1CodeableConceptHow it was done
                                                            Binding: ?? (example): Methods for simple observations.

                                                            S1..1CodeableConceptHow it was done
                                                            Binding: ?? (extensible)
                                                            • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                            • Element minimum cardinalities differ: '0' vs '1'
                                                            ... specimen 0..1Reference(Specimen)Specimen used for this observation0..1Reference(Specimen)Specimen used for this observation
                                                              ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)Not used in this profile
                                                              • Elements differ in short: '(Measurement) Device' vs 'Not used in this profile'
                                                              • Elements differ in definition: 'The device used to generate the observation data.' vs 'Not used in this profile'
                                                              ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                                              C0..*BackboneElementNot used in this profile
                                                              • Elements differ in short: 'Provides guide for interpretation' vs 'Not used in this profile'
                                                              • Elements differ in definition: 'Guidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two `referenceRange` elements would be used.' vs 'Not used in this profile'
                                                              .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                .... extension 0..*ExtensionAdditional content defined by implementations
                                                                0..*ExtensionAdditional content defined by implementations
                                                                  .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                  ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                    .... low C0..1??Low Range, if relevantC0..1??Low Range, if relevant
                                                                      .... high C0..1??High Range, if relevantC0..1??High Range, if relevant
                                                                        .... type 0..1CodeableConceptReference range qualifier
                                                                        Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                        0..1CodeableConceptReference range qualifier
                                                                        Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                          .... appliesTo 0..*CodeableConceptReference range population
                                                                          Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                          0..*CodeableConceptReference range population
                                                                          Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                            .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                              .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                                ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                                Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Not used in this profile
                                                                                • Elements differ in short: 'Used when reporting vital signs panel components' vs 'Not used in this profile'
                                                                                • Elements differ in definition: 'Used when reporting vital signs panel components.' vs 'Not used in this profile'
                                                                                • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                                ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                                Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
                                                                                  ... Slices for component SΣC0..*BackboneElementUsed when reporting flow rates or oxygen concentration.
                                                                                  Slice: Unordered, Open by pattern:code
                                                                                  Σ0..*BackboneElementComponent results
                                                                                  • Elements differ in short: 'Used when reporting flow rates or oxygen concentration.' vs 'Component results'
                                                                                  • Elements differ in definition: 'Used when reporting flow rates or oxygen concentration.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
                                                                                  • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                  .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                                    .... extension 0..*ExtensionAdditional content defined by implementations
                                                                                    0..*ExtensionAdditional content defined by implementations
                                                                                      .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                      ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                        .... code SΣ1..1CodeableConceptType of component observation (code / type)
                                                                                        Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.

                                                                                        Σ1..1CodeableConceptType of component observation (code / type)
                                                                                        Binding: ?? (example): Codes identifying names of simple observations.

                                                                                        • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                        • Elements differ in binding.description: 'The vital sign codes from the base FHIR and US Core Vital Signs.' vs 'Codes identifying names of simple observations.'
                                                                                        .... value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Component Value
                                                                                        Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                                                        Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                                                        • Elements differ in short: 'Vital Sign Component Value' vs 'Actual component result'
                                                                                        • Elements differ in definition: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
                                                                                        • Elements differ in requirements: '9. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
                                                                                        • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                        .... dataAbsentReason SC0..1CodeableConceptWhy the component result is missing
                                                                                        Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                        C0..1CodeableConceptWhy the component result is missing
                                                                                        Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                        • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                        .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                                        Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                        0..*CodeableConceptHigh, low, normal, etc.
                                                                                        Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                          .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                                          0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                                            doco Documentation for this format